background image

www.ikancorp.com | 1.713.272.8822 | [email protected] 

because we’re 

filmmakers

 too

Periodic Fixture Inspection

1.  The condition of the internal wiring and ceramic base will need to be inspected and tested every 4000 hours or at least once a year. This frequency 

may need to be increased if the fixture has endured rough treatment. All internal components should only be replaced with Lightstar spare parts.

2.  The lamps should be checked every 100 working hours. The lamp should be changed if the lamp becomes deformed or damaged, otherwise explosion 

might occur. Defer to instructions provided by the lamp manufacturer.

3.  Always check the safety shield before every use.
4.  All high-voltage components (ex:voltage wires, lamp ceramic, external shield, igniter must be inspected every 100 working hours or at least once a 

year).

5.  Outer door hinges and latching system must be checked every 250 working hours to ensure proper seating of the safety shield. This will allow 

inspections of accessories and the holding clamps.

6.  The condition of the internal mirror must be maintained every 250 working hours. It must be replaced whenever it becomes either cracked or broken. 

It is essential for the performance of the fixture.

Specifications

Optional Accessories

Some other products that work well with the LSP-004 available from Ikan include:

LEB-006
LEB-007

12kW/6kW Electronic Ballast (Lightstar)
18kW/12kW Electronic Ballast (Lightstar)

Fixture Specifications

Beam Angle

7-43°

Build Material

Aluminum

Color Temperature

5600K

Control

Focus Knob

Fixture Size

43.2 x 31.5 x 32.3 in.

Fixture Weight

143 lbs

IP Class

IP23

Lamp Base

12000W / 160V / G38

Lens

20

"

LUX: (Flood)

15m: 8133 lux
20m: 4565 lux
25m: 2980 lux

LUX: (Spot)

15m: 72911 lux
20m: 41070 lux
25m: 26256 lux

Содержание LSP-004

Страница 1: ...uick Start Guide 12kW HMI PAR Head Lightstar What s Included 1 x 6000 Watt Fixture Head 1 x 5 Lens Set 1 x Yoke 1 x Barn Doors 1 x Gel Holder www ikancorp com 1 713 272 8822 sales ikancorp com because we re filmmakers too ...

Страница 2: ...W HMI Fresnel Head is compact dual power PAR light The fixture uses 12000W 160V G38 socket metal handle lamps Safety Precautions 1 The fixture has been designed for professional use and must be operated by qualified personnel only 2 The 12kW fixture can only be used with the Lightstar electronic ballast that supports 12kW Lamp Installation Replacement Ensure the fixture is disconnected from the ma...

Страница 3: ...d every 100 working hours or at least once a year 5 Outer door hinges and latching system must be checked every 250 working hours to ensure proper seating of the safety shield This will allow inspections of accessories and the holding clamps 6 The condition of the internal mirror must be maintained every 250 working hours It must be replaced whenever it becomes either cracked or broken It is essen...

Страница 4: ... service fee will be charged if the warranty period is expired Free Service will not be Provided in the Following Situations Even if the product is still within the warranty period Damage caused by abuse or misuse dismantling or changes to the product not made by the company Damage caused by natural disaster abnormal voltage and environmental factors etc 2017 ikan Corporation All rights reserved w...

Отзывы: