Periodic Fixture Inspection

1.  The condition of the internal wiring and ceramic base will need to be inspected and tested every 4000 working hours 

or at least once a year. This frequency may need to be increased if the fixture has endured rough treatment. All internal 
components should only be replaced with Lightstar spare parts. 

2.  The lamps should be checked every 100 working hours. The lamp should be changed if the lamp becomes deformed or 

damaged, otherwise explosion might occur. Defer to instructions provided by the lamp manufacturer.  

3.  Always check the safety shield before every use. 

4.  All high-voltage components (ex: voltage wires, lamp ceramic, external shield, igniter must be inspected every 100 

working hours or at least once a year. 

5.  Outer door hinges and latching system must be checked every 250 working hours to ensure proper seating of the safety 

shield. This will allow inspections of accessories and the holding clamps. 

6.  The condition of the internal mirror must be maintained every 250 working hours. It must be replaced whenever it 

becomes either cracked or broken. It is essential for the performance of the fixture.

Specifications & Photometrics

LSC-007 Specifications

Beam Angle

9° to 60°

Build Material

Aluminum

Color Temperature

5600K

Cooling System

Air Cooled

Fixture Size

27 x 34 x 41 in.

Fixture Weight

85 lbs

Focusing

Knob Control

Head Type

HMI Fresnel 12000W

IP Class

IP23

Lamp Base

12000W / 160V / G38

Lens Size

Fresnel 19.7"

Yoke

Cast Aluminum with 1 1/8" Pin

LUX

METERS

20M

25M

30M

25500

16320

11330

LUX

METERS

20M

25M

30M

1575

1008

700

FC

FEET

65.6'

82'

98'

2369

1516

1052

FC

FEET

65.6'

82'

98'

146.3

93.6

65

Отзывы: