Working Conditions
The best position is tilting the fixture 90° from horizontal.
The max ambient temperature limit is ±45° C (113°F).
Please keep a minimum distance of 2 feet when close to inflammable objects.
Do not cover the ventilation holes on the fixture housing.
They are necessary for proper ventilation.
Use only original parts and accessories from Lightstar.
Before hanging the fixture, make sure the suspension points are properly rated to handle the weight of the fixture.
It is ALWAYS advisable to add a safety cable or chain through the yoke to properly suspend the fixture in place.
WARNING: DO NOT USE THE FIXTURE IN A SPACE WITH FLAMMABLE SUBSTANCES.
WARNING: UV RISK / HEALTH RISK. THE LAMPS USED WITH THE FIXTURE EMIT AN AMOUNT OF UV RADIATION WHICH CAN BE DANGEROUS TO
HUMAN HEALTH IF NOT PROPERLY SHIELDED AGAINST.
THE FIXTURE MUST NEVER BE USED IN SITUATIONS WHEN DIRECT LIGHT EMISSIONS FROM THE LAMP CAN OCCUR. (Ex: No front glass, no
intentional mirror, damaged front housing).
The Lightstar LSP-002 2500/4000 Watt HMI Fresnel Head is compact, dual power, PAR light. The fixture uses 2500W 115V G38 or 4000W 200V G38
socket metal handle lamps.
Safety Precautions
1. The fixture has been designed for professional use and must be operated by qualified personnel only.
2. The 2500/4000W fixture can only be used with the Lightstar electronic ballast that supports 2500W or 4000W.
Lamp Installation & Replacement
Ensure the fixture is disconnected from the main power supply.
WARNING!! LAMP WILL STILL BE HOT TO THE TOUCH EVEN AFTER THE ALLOTED LAMP REST PERIOD.
THERMAL GLOVES ARE RECOMMENDED FOR WORKING WITH FIXTURE AND THE BULB.
Check to see that the new lamp is the correct wattage.
Release the lamp clamp level inside the front of the fixture.
To replace the lamp pull up and out to remove the old lamp.
Re-Lamp Procedures: Do not touch the bulb with your bare-hands. This can cause oil to accumulate on the glass and
reduce the performance of lamp life. The plastic/foam cover which protects the lamp should NOT be removed until after
the lamp is fitted into the fixture. If bulb becomes dirty due to hand contact or from any contaminant, it can be cleaned
with a cloth moistened with alcohol.
Re-tighten the lamp clamping device.