Periodic Fixture Inspection
1. The condition of the internal wiring and ceramic base will need to be inspected and tested every 4000 hours or at least once a year. This frequency
may need to be increased if the fixture has endured rough treatment. All internal components should only be replaced with Lightstar spare parts.
2. The lamps should be checked every 100 working hours. The lamp should be changed if the lamp becomes deformed or damaged, otherwise explosion
might occur. Defer to instructions provided by the lamp manufacturer.
3. Always check the safety shield before every use.
4. All high-voltage components (ex:voltage wires, lamp ceramic, external shield, igniter must be inspected every 100 working hours or at least once a
year).
5. Outer door hinges and latching system must be checked every 250 working hours to ensure proper seating of the safety shield. This will allow
inspections of accessories and the holding clamps.
6. The condition of the internal mirror must be maintained every 250 working hours. It must be replaced whenever it becomes either cracked or broken.
It is essential for the performance of the fixture.
Specifications
Optional Accessories
Some other products that work well with the LSP-003 available from Ikan include:
LEB-005
KCP-703
6000 Watt Electronic Ballast (Lightstar)
Stage Clamp with 16mm Stud
Fixture Specifications
Beam Angle
7-40°
Build Material
Aluminum
Color Temperature
5600K
Control
Focus Knob
Fixture Size
37.5 x 24.4 x 27.8 in.
Fixture Weight
88 lbs
IP Class
IP23
Lamp Base
6000W / 123V / G38
Lens
17
"
LUX: (Flood)
15m: 7177 lux
20m: 4036 lux
25m: 2600 lux
LUX: (Spot)
15m: 49090 lux
20m: 27568 lux
25m: 117690 lux