background image

6

7

/// Working with the device

 Danger!

›  Do not use the device in explosive atmospheres, it is not EX-protected�
›  With substances capable of forming an explosive mixture, appropriate safety measures must 

be applied, e�g� working under a fume hood�

›  To avoid body injury and property damage, observe the relevant safety and accident 

prevention measures when processing hazardous materials�

 Warning!

›  Only process media that will not react dangerously to the extra energy produced through 

processing� This also applies to any extra energy produced in other ways, e�g� through light 
irradiation�

›  Beware of hazards due to:

-  flammable materials,
-  glass breakage,
-  incorrect container size,
-  overfilling of media,
-  unsafe condition of container�

›  Process pathogenic materials only in closed vessels under a suitable fume hood� 

Explication of warning symbols

EU Declaration of conformity

/// Warning symbols

/// General Symbols

Note
Indicates steps of actions that require particular attention�

Position number
Indicates device components relevant to actions�

A–––

Correct / result
Indicates the correct execution or the result of an action step�

Wrong
Indicates the incorrect execution of an action step�

We declare under our sole responsibility that this product corresponds to the directives 2014/35/EU,
2006/42/EC, 2014/30/EU and 2011/65/EU and conforms with the following standards or nor-
mative documents: EN 61010-1, EN 61010-2-051, EN 61326-1, EN 60529 and EN ISO 12100�
A copy of the complete EU Declaration of Conformity can be requested at 

[email protected]

Source language: German

Indicates an (extremely) hazardous situation, which, if not avoided, will 
result in death, serious injury�

Danger!

Indicates a hazardous situation, which, if not avoided, can result in 
death, serious injury�

Warning!

Indicates a potentially hazardous situation, which, if not avoided, can 
result in injury�

Caution!

!

Indicates practices which, if not avoided, can result in equipment dam-
age�

Notice!

Indicates the risks due to magnetism�
Effects of the strong  magnetic field have to be taken into account, 
which can result in risks of injury (cardiac pacemakers, data storage 
media, crushing���)�

Attention!

/// General information

› 

Read the operating instructions completely before starting up and follow the 

safety instructions.

›  Keep the operating instructions in a place where it can be accessed by everyone�
›  Ensure that only trained staff work with the device�
›  Follow the safety instructions, guidelines, occupational health and safety and accident 

prevention regulations�

›  Electrical outlet must be grounded (protective ground contact)�

 

 Attention – Magnetism! 

›  Effects of the magnetic field have to be taken into account (e�g� data storage media, cardiac 

pacemakers ���)�

 Caution!

›  Pay attention to the marked sites in 

Fig. 1

Safety instructions

/// Device design

 Caution!

›  Device surface is partially made of glass:

-  Glass surface can be damaged by impact�
 -  If glass surface is damaged it could cause injury, don`t use the device anymore�

!

 Notice!

›  Set up the device in a spacious area on an even, stable, clean, non-slip, dry and fireproof surface�
›  The feet of the device must be clean and undamaged�
›  Keep the setup plate clean�
›  Ensure that the vessel stands safely on the device�
›  Protect the device and accessories from bumps and impacts�
›  Check the device and accessories for damage before each use� Do not use damaged 

components�

›  Please note that the housings of the I-MAG stirring system, consisting of I-MAG CP and 

I-MAG 300, have different protection classes (see "Technical data - Protection class")�

!

Indicates the exposure to a hot surface�

Danger!

Содержание I-MAG 300

Страница 1: ...I MAG...

Страница 2: ...ENGLISH...

Страница 3: ...ation of conformity 6 Explication of warning symbols 6 Interfaces and outputs 22 Operator panel and display 12 Warranty 27 Useful information 10 Maintenance and cleaning 24 Accessories 24 Intended use...

Страница 4: ...hazardous situation which if not avoided can result in death serious injury Warning Indicates a potentially hazardous situation which if not avoided can result in injury Caution Indicates practices wh...

Страница 5: ...l IKA accessories Always disconnect the plug before attaching accessories Observe the operating instructions of the accessories Power supply Switching off the device Warning The device will automatica...

Страница 6: ...ge within the permitted tolerance range have no effect on the quality of regulation and constancy of speed The speed is set using the rotating pressing knob Dur ing normal operations the speed value o...

Страница 7: ...terface analog signal output O Setup plate P Connection cable I MAG CP G A H I J K L M N Menu O P C B D E F Back Display 1 Set speed value 2 Actual speed value 3 Counter Timer 4 Button lock 5 Pedal sw...

Страница 8: ...00 500 247 actual rpm set rpm Counter A dd hh mm 18 ss 00 00 00 500 500 actual rpm set rpm 1 3 5 2 4 Back Back Counter A dd hh mm 28 ss 00 00 00 500 0 actual rpm set rpm Counter A dd hh mm 00 ss 00 00...

Страница 9: ...m etc Stirring bar decoupling monitoring does not work if the stirring bar already breaks away before the system has reached the set target speed Intermittent mode The Intermittent mode is a cyclic in...

Страница 10: ...nob Using the Edit Insert or Delete buttons you can make the corresponding changes In a program user can define up to 10 program segments The selected program segment is highlighted in blue When editi...

Страница 11: ...onding parameter you want to reset with the rotating pressing knob The system will prompt you to confirm the restoration of the selected factory setting Press OK button to reset all the system setting...

Страница 12: ...and their properties are detected automatically The USB interface is used in conjunction with software control for remote operation and can also be used for software update of the device USB device dr...

Страница 13: ...tear of components and their statistical failure rate Cleaning For cleaning disconnect the mains plug Use only cleaning agents which have been approved by IKA to clean IKA devices These are water cont...

Страница 14: ...from improper use insufficient care or maintenance not carried out in accordance with the instructions in this operating manual Technical data General data I MAG 300 I MAG CP Voltage 100 240 V Frequen...

Страница 15: ...2 eMail sales england ika com MALAYSIA IKA Works Asia Sdn Bhd Phone 60 3 6099 5666 eMail sales lab ika my CHINA IKA Works Guangzhou Phone 86 20 8222 6771 eMail info ika cn POLAND IKA Poland Sp z o o P...