20
10.3 DEVICE SETTINGS
From the top bar, click on the settings icon to access the settings panel. Now select one or more devices
from the device list (multiple selection: c click on macOS and ctrl + click on Windows) to
display the settings.
Distance: You can use the slider to set “Warning” and “Danger” status on your device. Move the slider
to set a distance range for each status. By default, the “Warning” status is set to 2 meters (6.6 feet) and
the “Danger” status is set to 1.2 meters (3.9 feet). From the Global Settings menu, you can set the unit of
measure (meters or feet) you want to display for the distance settings.
Alert: Set the vibration, sound and light for the Warning and Danger status
Firmware: Click on the “Browse” button to upload a firmware update file and proceed to update firmware
on the devices
Always click “Apply” in order to complete the edit of the settings.
PLEASE NOTE: All settings will be applied to the next device synchronization.
PLEASE NOTE: Alert settings cannot be applied to multiple devices simultaneously.