Be sure to enter the Factory Mode by using the short-connector.
Connect the interface adapter from RS-232C of the color analyzer to the
PWB-RS of the short-connector.
Select VIDEO IN 2 for the signal input and receive a white window signal
of MODE 5.
Turn OFF the R, G and B outputs on the signal generator.
Apply a color analyzer probe to the center of the screen.
Turn ON the Remote Switch of the color analyzer so that the automatic
CUT-OFF adjustment starts.
Turn ON the R, G and B outputs on the signal generator so that the
COLOR TEMPERATURE and CONTRAST LIMIT adjustments start
automatically.
<COLOR TEMPERATURE>
The X and Y specified readings of the color analyzer are as follows:
<CONTRAST>
The specified contrast range is 120±6cd/m
2
.
Note:
In case that the contrast is not within the specified range above,
repeat 4) to 7).
The OSD disappears.
Press the MENU Button so that the OSD appears.
All adjustment data is stored when the OSD disappears.
Turn OFF the Remote Switch of the color analyzer.
CT 1 (9300K)
X: 0.283±0.008
Y: 0.297±0.008
1
0
B. P. S. DIP switch
1-14. Automatic COLOR adjustments
WARNING:
- 8 -
Do not change the horizontal and vertical sync signal or the frequency
while the automatic COLOR adjustments are underway.
Color analyzer setting:
Luminance unit switch: cd/m
2
B.P.S. DIP switch: 9600 (1000)
Turn ON the color analyzer switch and press 0-CAL switch before use.
1)
2)
3)
4)
5)
6)
7)
l
l
l
cd/m²
fL
Luminance unit switch
Note:
The adjustments above can be repeated by turning OFF and ON the
Power Switch.
n
1)
2)
Receive a 16-gradation gray scale signal of MODE 5.
Make sure the 15th gradation on the gray scale is barely visible when the
16th gradation (back raster) is not visible at all.
1-15. GRAY SCALE confirmation
n
8)
9)
10)
11)