Installation
2021-07-06
29
4.2 System Setup
First time users are recommended to setup the system with the CPU Unit
and the CON Unit in the same room as a test setup. This will allow you to
identify and solve any cabling problems, and experiment with your system
more conveniently.
Please verify that interconnect cables, interfaces, and handling of the
devices comply with the requirements (see Chapter 7, Page 38).
4.2.1 SDI Extender Setup
1. Switch off all devices.
CON Unit Installation
2. Connect your SDI monitor to the CON Unit.
3. Connect the CON Unit with the interconnect cable(s).
4. Connect the power supply to the CON Unit.
CPU Unit Installation
5. Connect the source (e.g. SDI camera) to the CPU Unit with your
cables. Please ensure the cables are not strained.
6. Connect the CPU Unit to the interconnect cable(s).
7. Connect power supply to the CPU Unit.
8. Power up the system.
To power up the system, the following sequence is recommended:
Monitor – CON Unit – CPU Unit – source.