Draco U-Switch
Technical Data
45
9.3 Power Supply, Current Draw and Power Consumption
NOTICE
Overheating of the power supply units
In case of having redundant power supply units, the maximum current must not exceed the value of one
of the two power supply units due to the heat dissipation.
9.3.1 Power Supply of the Chassis (AC)
Product type
Maximum current draw Maximum voltage AC
Frequency
474-BODY2N
700 mA
100 V to 240 V
50/60 Hz
474-BODY2BPF
700 mA
100 V to 240 V
50/60 Hz
474-BODY6R-R1
1,500 mA
90 V to 264 V
47-63 Hz
474-BODY6BP
1,300 mA
100 V to 240 V
50/60 Hz
474-BODY6BPF
1,300 mA
100 V to 240 V
50/60 Hz
474-BODY21/4U
4,000 mA
2x 100 V to 240 V
50/60 Hz
9.3.2 Power Supply of the Chassis (DC)
Product type
Maximum current draw Maximum voltage DC
474-BODY2
3,000 mA
5 V
474-BODY2R
3,000 mA
5 V
474-BODY2N
5,000 mA
5 V
474-BODY2BPF
5,000 mA
5 V
474-BODY4
5,000 mA
5 V
474-BODY4R
5,000 mA
5 V
474-BODY6R-R1
12,000 mA
5 V
9.3.3 Power Supply of the U-Switch Module and Add-on Modules
NOTICE
Exceeding the maximum permissible current draw
In addition to the current draw of the U-Switch module and add-on modules, there is also the current draw
of the connected peripherals.
Note the maximum current draw of the housing (see from chapter 9.3, page 45).
Product type
Maximum current draw
Maximum power consumption
B476-4U4T
1,710 mA
8 W
R474-BGX
10 mA
0 W