Configuration via Management Software
Draco Multiview 4K60
66
Option
Description
Acoustic
Notification
Outputs an acoustic error message
Autostart
When starting the management software, the syslog function will be
started in the background
Open Monitoring
Tab
When starting the management software, the monitoring tab will be
opened
When reaching the maximum log file size, a new log file will be created. When reaching the
maximum number of log files, the oldest logfile will be overwritten with the new information.
6.3.4 Setting SNMP Function
The SNMP function allows all function-critical and safety-critical elements of the Draco MV to be
monitored and queried. This function complies with the RFC 1157 conformal standard. Two
SNMP servers can be used at the same time.
NOTICE
When using SNMP monitoring, for reasons of access security, the use of a dedicated network
according to the IT-Grundschutz catalog is recommended. The read only community for the MIB
file is
draco
.
NOTICE
For an activation of the SNMP agent function or the SNMP server function, a restart of the
Draco MV is necessary.
Fig. 48 Menu
Configuration - SNMP