Table of Contents
Draco U-Switch
40
6.2 Activating/Deactivating the Routing of USB-2.0-Ports
To activate or deactivate the routing of the USB 2.0 ports to the four USB-B ports, a parameter can be
entered in the configuration file (
Config.txt
).
Configuration File
The U-Switch contains a configuration file (
Config.txt
) to set specific parameters. The configured
display mode of the MSC is also saved in the
Config.txt
.
The
Config.txt
is located on the flash drive of the U-Switch. The flash drive can be opened by a
Mini-USB connection to a computer. The configuration file can be edited with all common text editors.
NOTICE
To ensure the functionality of the parameterization:
The start command
#CFG
has to be written into the first line of the
Config.txt
file.
The U-Switch needs to be restarted.
Firmware Requirements
The following firmware is required as a minimum:
Firmware
Version
Release date
HUSWMSD
B01.07
2020-11-27
HUSWITCH
F01.05
2020-12-16
Parameters
The following parameter settings are available:
Parameters
Functions
ENAUSB20=1111
Activate all ports (default)
ENAUSB20=1000
Activate the routing of port 1
ENAUSB20=1100
Activate the routing of port 1 and port 2
ENAUSB20=1010
Activate the routing of port 1 and port 3
ENAUSB20=1001
Activate the routing of port 1 and port 4
ENAUSB20=0100
Activate the routing of port 2
ENAUSB20=0110
Activate the routing of port 2 and port 3
ENAUSB20=0101
Activate the routing of port 2 and port 4
ENAUSB20=0010
Activate the routing of port 3
ENAUSB20=0011
Activate the routing of port 3 and port 4
ENAUSB20=0001
Activate the routing of port 4
ENAUSB20=0000
Deactivate the routing of all ports
NOTICE
For a successful setting of the USB 2.0 ports, the following sequence must be strictly observed.