Draco ultra DisplayPort KVM Extender
56
2016-02-29
In order to configure a redundant CPU Unit for the operation with two
competing CON Units, proceed as follows:
1. Connect a redundant CPU Unit to any source (computer, CPU) by
using a mini USB connection.
2. Open the file "Config.txt" that is located on the appearing flash drive
of the extender.
3. Activate the release timer by writing the parameter
RELEASETIME=n
into the second line. The variable "n" defines the time in seconds and
has to be replaced by the numbers 0 to 9 (e.g. RELEASETIME=5).
If this parameter is not activated at all, the release time is set to
2 seconds by default.
The parameter
RELEASETIME=X
deactivates the shared operation.
4. Save
your
changes.
5. Reboot the CPU Unit.
Example View –
Config.txt
When using redundant CPU Units in combination with a KVM matrix, the
function of competing control will be automatically deactivated in the
extender and will have to be performed by the KVM matrix.
Pos: 66 /806-IHSE/Technische Daten/UEB_Technische Daten @ 5\mod_1278578165261_6.doc @ 42096 @ 1 @ 1