background image

1

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

KIT CONTENTS

1 ea. UZY6 Blower Assembly

1 ea. Mill-pack

1 ea. Instruction Sheet

TOOLS NEEDED

Robertson (square) or Phillips (star) screwdriver

INSTALLATION INSTRUCTIONS FOR INSTALLING UZY6 REPLACEMENT BLOWER KIT
FOR USE WITh WOOD-BURNING FIREPLACES LISTED IN TABLE 1

       WARNING

The blower must be plugged directly into a properly 

grounded three-prong receptacle, 120 VAC, 60 hz, 

single phase. Do not cut or remove the grounding prong 

from this plug.  
Installation must be in accordance with National Elec-

trical Code, ANSI/NFPA 70 - latest edition.  In Canada, 

the current CSA C22.1 Canadian Electrical Code - latest 

edition.

UZY6 REPLACEMENT BLOWER KIT

Cat. No.

Model

Where Used

PR-UZY6

UZY6

Ladera™, BIS

®

 Nova, Brentwood™ LV, 

BIS Ultima CF

Table 1

Figure 1

GENERAL INFORMATION

The UZY6 blower kit is a replacement part kit for the standard air-circulating 

blower provided with the fireplace.
If you encounter any problems, need clarification of these instructions or 

are not qualified to properly install this kit, contact your local distributor 

or dealer.
Read this instruction sheet in its entirety before beginning the installation.

ALL WARNINGS AND PRECAUTIONS IN ThE INSTALLATION AND 

OPERATION MANUAL PROVIDED WITh ThE APPLIANCE APPLY TO 

ThESE INSTRUCTIONS.
ShUT DOWN ThE APPLIANCE AND ALLOW IT TO COMPLETELY COOL 

BEFORE PROCEEDING.

UZY6 BLOWER KIT

P/N 506019-80 

Rev. B, 07/2013

HEARTH PRODUCTS

KITS AND ACCESSORIES

INSTALLATION INSTRUCTIONS

Step 1.

  Remove the andirons, using a square or phillips screwdriver. 

Then remove front and bottom refractories.

Step 2.

  Unscrew the access plate located in the firebox floor (12 screws). 

Remove the access plate and the high heat cement used to seal 

it.

Step 3.

  Unplug the blower from the electric receptacle located on the 

right side of the fireplace.

Step 4.

 Unscrew the blower using a Robertson (square) or Phillips 

(star) screwdriver. The location of the two screws depends on 

the version of the blower installed (see Figure 1). They can be 

at each end of the support bracket close to the floor (Version B) 

or on top of the support bracket near the left side (Version A). 

See figure 1.

Step 5.

  Take the blower out of the fireplace through the access opening.

Version A

Unscrew these two screws

Version B

Or these screws

to remove the blower

F161  REV. 2  07/2013