D.  Wet wood 

  Wet or tarred wood will smoulder and smoke 

instead of burning properly. Your dealer can 

help you determine if you have properly 

seasoned wood for burning.

E.  Dirty or blocked chimney

  Check to make sure the chimney is clear and 

clean. If dirty call a certified chimney sweep 

or use a properly sized chimney brush to 

clean.

F.  Chimney not long enough

  The minimum chimney height is twelve 

(12) feet (3.7 m) not including the fireplace 

height.  The chimney must extend at least 

three (3) feet (915 mm) above its point 

of contact with the roof and at least two 

(2) feet (610 mm) higher than any roof or 

wall within ten (10) feet (3 m) of it.  When 

installed with offsets, the minimum chimney 

height is fifteen (15) feet (4.6 m).  Additional 

height will increase draft and will decrease 

the tendency to smoke.

G.  Poor chimney draft

  With no fire, there should be sufficient draft to 

exhaust cigarette smoke introduced under the 

baffle.  Chimneys installed against an outside 

wall without protection or a basement installa-

tion may generate back draft problems which 

will cause start-up problems.  To prevent this, 

open a nearby window, roll up a piece of paper 

and light it.  Then, hold it in the upper part of 

the firebox to warm up the chimney.  Wait until 

the draft is sufficient, then start the fire.

H. Blower for forced air kit operating - 

Make 

sure that the blower is at the “off” position 

when you open the fireplace door for reloading.

IMPORTANT CAUTIONS

A. Do not block any hot air vents from the 

fireplace as this will cause the fireplace 

to overheat.

B. Never use gasoline, gasoline-type lantern 

fuel, kerosene, charcoal lighter fluid, or 

similar liquids to start or ‘freshen up’ a fire 

in this fireplace.  Keep all such liquids well 

away from the fireplace while it is in use.

C. Do not burn coal.  The sulphur in coal will 

corrode the firebox.

D. Do not burn driftwood which has been in the 

ocean or salt water.  The salt will corrode 

the firebox and chimney.

E.  Do not operate the unit with the door partly 

open since this may cause smoke to be 

drawn into the room.

F.  Do not burn wood in the area in front of the 

andirons.

G. Do not abuse the unit by burning paper, or 

cardboard or construction material such as 

pressed wood, plywood or lumber.  Wood 

protectors, metallic paper, coal, plastic, 

waste, sulphur and/or oil will damage the 

fireplace.

H. Do not allow the wood to smoulder or burn 

without flame, since this will produce 

excessive creosote in the unit as well as 

increased particulate emissions.

STARTING AND MAINTAINING A FIRE

Step 1.

 Place several crumpled up balls of 

newspaper in the firebox.  Place small dry pieces 

of kindling on top of the paper, criss-crossing 

the kindling so that there are air spaces in 

between. The kindling should be placed at the 

center of the firebox so as to allow for sufficient 

air circulation. 

Step 2.

 Adjust the primary air control into the 

OPEN position. Light the newspaper. Leave the 

door partially opened to facilitate the start-up.

Step 3.

 Once kindling fire is well established, 

cord wood can be added. You may set the 

primary air control to the desired level (see 

Primary Air Combustion Control

 section for 

proper operation of the air controls). Close the 

door and maintain an accelerated combustion 

air set up in order to achieve combustor light-

off conditions. 

Step 4.

  When the fire is burning well, and you 

can see the gauge needle in the catalytic com-

bustor operating range, close the CAT bypass 

damper control by pushing the control rod in.  It 

takes about 15–30 minutes with the CAT bypass 

opened to reach proper light-off temperatures 

for the catalytic combustor.

Step 5.

 Set the primary control to the desired 

burn level. The fireplace will automatically go 

to that level after the fire is fully established.
The unit will burn best with 2-3 pieces of cord 

wood spaced 1 to 2 inches apart and allowing 

air to get under the fuel.  Criss-crossing or ar-

ranging the fuel so that air can get underneath 

will help the fire to get started easily. The unit 

should be operated with the air control fully open 

long enough to get the cord wood well ignited.

REFUELING FOR BEST PERFORMANCE

To refuel the fireplace at the end of a burn cycle 

when only hot embers remain and flames are 

gone (not enough heat to maintain catalyst 

operating temperatures):

Step 1

. Open the CAT Bypass fully

 (see

 

Figure 5

)

.

Step 2

. Completely open the air control level. 

See 

Figure 2

.

Step 3

. Open the door about 1” and wait 5 

seconds until the air flow has stabilized.  Then 

open the door completely, put the logs in and 

close the door. 

Step 4

. Set the air control to the desired burn 

level. Open the CAT bypass damper for 10 min-

utes before closing it. It will ensure sufficient 

temperatures for combustor light-off.

To refuel the 

WRT3920WS

 fireplace when the 

unit is still hot (some burning fuel remaining 

or a glowing combustor)

A. Open the air control and the CAT bypass 

completely. 

B. Open the door about 1” and wait 5 seconds 

until the air flow has stabilized.  Load the fuel, 

close the door and CAT bypass (temperatures 

within the firebox should be enough to 

maintain catalytic operation).

C. Set the air control to the desired burn level.

NOTES: 

•  For spectacular fire and optimization of  the 

fireplace efficiency, we recommend that the 

wood load be placed as far back as possible.

•  It may be necessary to turn off any blower(s) 

in operation during the refueling process in 

order to minimise smoking in the room.  It 

is recommended to wait 15 to 30 minutes 

before turning the blower back on to ensure 

successful rekindling.

SMOKING – 

CAUSES AND TROUBLESHOOTING

To reduce the likelihood of smoke coming 

into the room when opening the door, set the 

combustion air controls to the left (“Acceler-

ated Combustion”) and open the CAT bypass 

before opening the door.  Your fireplace has 

been designed and tested to provide smoke 

free operation.

As the fire burns, air goes up the chimney.  

This air must be replaced through the outside 

air duct.  When operating the fireplace, open a 

nearby window temporarily to check if there is 

adequate replacement air supply.  Occasionally, 

there may be a small amount of smoking upon 

lighting the fire, until the chimney heats up but 

this should not last.  If the fireplace continues 

to smoke it is probably for one of the follow-

ing reasons:

A. The door is partially opened - 

 When you 

open the door, open them completely.

B.  Negative pressure in the house

  As the fire burns, air goes up the chimney.  

This air must be replaced through leakage 

into the house or through the outside air duct 

(included with fireplace).  When operating the 

fireplace, open a nearby window temporarily 

to check if there is adequate replacement air 

supply.

C.  Fans operating (e.g.: range hood)

  These fans draw air out of the house and 

may actually cause a negative pressure in the 

house.  Turn off all fans and open a nearby 

window to determine if this is the cause of 

the problem.

REFUELING: During the refueling and 

rekindling of a cool fire, or a fire that has 

burned down to the charcoal phase, operate 

the stove at a medium to high firing rate for 

about 10 minutes to ensure that the catalyst 

reaches approximately 500°F.

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

6

Содержание Superior Fireplaces WRT3920WS

Страница 1: ...andapprovalsofthissystem and could result in an unsafe and potentially dangerous installation IHP wood burning fireplaces are designed for use as a supplemental heater They are not intended for contin...

Страница 2: ...intended for use with a gas log set Do not use a fireplace insert or any other product with this fireplace unless it is specified by IHP for use with this appliance Failure to follow these instructio...

Страница 3: ...length to be blown in front ofanopenflamewhenthewindow is opened Keep any combustible furniture materials or decorative pillows at least 48 1219 mm from the front fireplace opening WARNING Never leav...

Страница 4: ...sthecatalyticcombustor Openingthe CAT bypass damper control increases the draft allowing the unit to achieve proper operating temperatures during a cold start up It also provides more draft to prevent...

Страница 5: ...For instance a long chimney will necessitate closing the damper more To obtain the proper combustion closethedampercompletely then open it about 1 4 to 1 2 6 4mm to 13mm Two medium size pieces of woo...

Страница 6: ...kesabout15 30minuteswiththeCATbypass opened to reach proper light off temperatures for the catalytic combustor Step 5 Set the primary control to the desired burn level The fireplace will automatically...

Страница 7: ...ed to less than 20 Wood properly seasoned is then capable of generating the heat the stove was designed to provide Greenwooddoesnotburneasily Attemptingto burn green wood often results in a lot of smo...

Страница 8: ...sweep and put the combustor back in place CATALYTIC COMBUSTOR This fireplace is designed with a catalytic com bustor which will reduce pollution emissions and creosote build up while improving therma...

Страница 9: ...better seal and then retightening Catalyst Bypass linkage replacement see Figure 9B Toolsrequired 2 9 16 wrenches 2square drive bit driver Withcatalystbypassinclosedposition remove 2 baffle boards fr...

Страница 10: ...ombustorProblem Thermal Cracking ThiscombustordoesNOTexperiencethermalcracking Notap plicable Appliestohoneycombcombustorsonly CombustorProblem CombustorPeeling ThiscombustordoesNOTexperiencecombustor...

Страница 11: ...the ashes are cold 24 to 48 hours after the fire is out Do not leave the ashes in the house as they give off carbon monoxide and other toxic gases WARNING DisposalofAshes Ashesshould be placed in a st...

Страница 12: ...e Replacement Parts Page 28 DO NOT OPERATE THE UNIT WITH CRACKED OR BROKEN GLASS Glass Cleaning TheWRT3920WSfireplaceisdesignedtokeeptheglasscleanundernormal operating conditions If the WRT3920WS fire...

Страница 13: ...replace is determined by considering the location of windows doors and the traffic flow in the room where the fireplace is located allowing space in front of the unit for the hearth exten sion and the...

Страница 14: ...must cover the entire width of the fireplace The combustible floor in front of the fireplace must be covered with at least a 1 2 inch of non combustible material tile marble stone etc See Figure 15 CO...

Страница 15: ...phs are not to scale consult installation instructions Product designs materials dimensions specifications colorsandpricesaresubjecttochangeordiscontinu ance without notice Allframingdimensionscalcula...

Страница 16: ...Side Figure 17 Figure 18 Insulated Chase Construction 7 Ft Min Attic Radiation Shield Roof Support Storm Collar Flashing Drywall or Any Rigid Material 2 x 4 1 2 Plywood 6 8 Min Firestop Floor Ceiling...

Страница 17: ...mbustible Facing Drywall 2 x 3 Min Rock Board or Other Spacer Figure 22 A wall on off switch must be installed to control theblower Anoptionalheatswitchandvariable speed control are available see Page...

Страница 18: ...ust be non combustible below this area u NOTES Seal the top and both sides of the roof flashing with waterproof caulk ing The gap between the vent pipe and a vertical firestop shall be sealed with non...

Страница 19: ...the base of the fireplace C The fresh air must come from outside the house The air intake must not draw air from the attic basement or garage D The air intake should be installed where it is not likel...

Страница 20: ...2 feet 3 7 m In altitude add 18 450 mm to the chimney for every 2 000 feet 600 m above sea level 6 All chimney installations must include at least one support Re ducing the amount of chimney weight on...

Страница 21: ...the joint between the roof and the flashing with roofing pitch see Figures 34 and 35 For sloping roofs place the flashing under the upper shingles and on top of the lower shingles Nail the flashing to...

Страница 22: ...b bob to line up the center of the hole Cut a hole for the chimney in the ceiling floor Frame this hole as described previously refer to section Chimney Instal lation Instructions 5 From below install...

Страница 23: ...6 1 8 156 mm 11 280 mm 14 1 8 359 mm 16 7 8 429 mm 18 7 16 468 mm 23 584 mm 26 3 16 665 mm B 27 11 16 703 mm 33 1 2 851 mm 50 7 8 1292 mm 62 1 2 1588 mm 72 5 8 1845 mm 78 7 16 1992 mm 95 3 4 2432 mm...

Страница 24: ...Insulated Wall Angel Wall Radiation Shield Insulated Available from Security Chimneys Available from DuraVent Security Chimneys RSM and RSMI30 RSMI45 Canada Only DuraVent 6DTC WTI and 6DTC S30 6DTC S...

Страница 25: ...AND MULTIPLE TERMINATIONS For the purpose of this manual a chimney chase is considered a part of the chimney system rather than part of a building The termination must be placed a minimum of 18 460 mm...

Страница 26: ...rily install the ASHT elbow on the top of the fireplace and using a level mark with an oval the location where the flue liner will enter the masonry chimney 2 In the middle of the oval drill a hole in...

Страница 27: ...er EPA certification If installed this appliance no longer qualifies for EPA certification Check with local authorities having jurisdiction for requirements in your area Central Forced Air Kit Accesso...

Страница 28: ...ription Part Cat No Andiron 2 pieces PR SR2875 Bottom refractory PR SR2825 Back refractory PR SR2826 Left side refractory PR SR2828 Right side refractory PR SR2827 Front refractory 2 pieces PR SR2829...

Страница 29: ...nd PE Wall Band BM Supports Offset Support SO Roof Support ST Roof Brace BS2 Firestops Firestop 6BF Radiation Shield 6RS Insulated Attic Radiation Shield 6RSA2 Insulated Wall Radiation Shield 6RSM Ins...

Страница 30: ...Relining A Masonry Chimney 6 Diameter Listed to ULC S635M UL 1777 and ULC S640M at 2100 F Description Cat Part No 6 Length 6 Dia 6LL6 6LL6 12 Length 6 Dia 6LL12 6LL12 24 Length 6 Dia 6LL24 6LL24 36 Le...

Страница 31: ...E MANUEL D INSTALLATION LES COMPOSANTES UTILIS ES AVEC LE FOYER DOIVENT TRE HO MOLOGU ES VOIR LA LISTE DANS LE MANUEL D INSTALLATION REMPLACER LA VITRE AVEC UN VERRE C RAMIQUE DE 5mm D PAISSEUR POUR U...

Страница 32: ...ct d damages repairs or inefficiency resulting from faulty installation or application of the Product IHP is not responsible for inadequate system draft caused by air conditioning and heating systems...

Страница 33: ...l use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with abnormal burning cha...

Страница 34: ...See Page 28 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at pr...

Отзывы: