IHP Superior Fireplaces MHD40STDMN Скачать руководство пользователя страница 4

4

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

General Information

900608-00, 01/2019

Innovative Hearth Products
MHD40 Series Multi-View Direct-Vent Gas Fireplaces

TABLE OF CONTENTS 

Safety and Your Fireplace ......................... Page 2

Packaging ................................................ Page 4

Introduction ............................................. Page 4

General Information ................................. Page 4

Requirements for the 

   Commonwealth of Massachusetts ........ Page 6

Cold Climate Insulation ............................ Page 6

Manufactured Home Requirements ......... Page 7

Location ................................................... Page 7

Vent Termination Clearances  ................... Page 8

Appliance and Vent Clearances ................ Page 10

Detailed Installation Steps ........................ Page 12

Typical Installation Sequence  .................. Page 12

Step 1. Framing ........................................ Page 12

Fireplace and Framing Specifications ........ Page 13

Step 2. Routing Gas Line ......................... Page 15

Step 3. Appliance Vent Collar ................... Page 15

Step 4. Install The Venting System .......... Page 16

Vertical Termination Systems ................... Page 17

Vent Section Length Charts ...................... Page 17

Vertical Vent Tables and Figures ............... Page 21

Horizontal Termination System ................ Page 23

Horizontal Vent Tables and Figures .......... Page 25

Venting Using Flexible Vent Pipe .............. Page 28

Step 5.  Field Wiring .............................. Page 29

Step 6.  Connecting Gas Line ................ Page 30

Step 7.  Verifying Appliance Operation ...... Page 31

Step 8.  Installing Logs  ......................... Page 31

Step 9.  Remove/Install Glass Door  ...... Page 32

Step 10.  Burner Adjustments ................. Page 32

Step 11.  Install Front Face ...................... Page 34

Step 12.  Hood Installation ...................... Page 34

Finishing Requirements ........................... Page 34

Step 13. Attaching Safety in 

    Operation Warnings .......................Page 35

Installation Accessories ........................... Page 36

Gas Conversion Kits ........................Page 38

Operation ................................................. Page 40

Gas Controls Access ................................ Page 41

Variable Flame Adjustment ....................... Page 41

Attaching Safety in Operation Warnings ... Page 42

Maintenance ............................................. Page 43

Front Glass Enclosure Panel,

  Removal and Installation ........................ Page 44

Install Vermiculite, Embers 

   and Logs ............................................... Page 45

Burner Flame Appearance/Sooting ........... Page 48

Burner Flame Adjustments ....................... Page 48

Millivolt Appliance Checkout .................... Page 48

Wiring Diagrams ...................................... Page 49

Replacement Parts ................................... Page 49

Product Reference Information ................ Page 49

Accessory Components ........................... Page 50

Maintenance Schedule ............................. Page 52

Lighting Instructions – Millivolt ............... Page 53

Troubleshooting Guide – Millivolt............. Page 55

Replacement Parts List ............................ Page 56

Warranty .................................................. Page 57

Please read and understand these 

instructions before beginning your 

installation.

PACKAGING

The  assembled vented gas fireplace heater  is 

packaged with:

1 -  one log set located within the firebox.

2 - one plastic bag containing the literature 

package, which consists of (2 ea.) Instal-

lation and Operation manuals (one for the 

installer and one to be left with the appliance 

for the homeowner), hot glass warning 

flyer, glass and barrier flyer, warning labels, 

8 (MHD40ST), and 4 (MHD40PF) nailing 

flanges.

3 - two hoods (MHD40ST), or three hoods 

(MHD40PF)  taped to the top of the fireplace.

4 - one plastic bag of glowing embers, one 

plastic bag of decorative volcanic stone 

and one bag of vermiculate is located in 

the bottom control compartment.

5  -  one vent restrictor to be applied as shown on 

Page 16

;

 restrictor is taped to the envelope.

6 - barriers

7 - front face assemblies

8 -  one fuel conversion kit (Nat. Gas to LP Gas) 

located in the bottom control compartment.

NOTE:

•  If the barrier becomes dam-

aged, the barrier shall be re-

placed with the manufacturer’s 

barrier for this appliance.

•  For use with barrier(s) Part 

No(s). J7420 (ST Models),  

J7420 and J7421 (PF Models).

INTRODUCTION 

These 

Millivolt

 appliances have a millivolt gas 

control valve with piezo ignition system. If any 

optional accessories that will require electrical 

power are to be installed, the electrical power 

must be provided at the time of appliance instal-

lation. External electrical power is required to 

operate the (optional) forced-air blower.

These vented gas fireplace heaters are sealed 

combustion, air-circulating gas fireplaces de-

signed for residential applications. 

Approved Vent Components

 - These fireplaces 

are designed, tested and listed for operation 

and installation with the following vent com-

ponents only:  

   

Secure Vent

®

 Direct-Vent System Compo-

nents manufactured by IHP. 

   

Secure Flex

®

 Flexible Vent Components 

manufactured by IHP and 

   

Z-FLEX

®

 Model GA Venting Systems listed 

to UL1777 and ULCS635 manufactured by 

Flexmaster Canada Limited.

Use only the correct size venting (4-1/2" inner 

and 7-1/2" outer).
These approved vent system components are 

labeled for identification.  DO NOT use any 

other manufacturer’s vent components with 

these appliances.  

 

Children and adults should be alerted to the 

hazards of high surface temperature and 

should stay away to avoid burns or clothing 

ignition. 

Les enfants et les adultes devraient être infor-

més des dangers que posent les températures 

de surface élevées et se tenir à distance afin 

d’éviter des brûlures ou que leurs vêtements 

ne s’enflamment.

DO NOT ATTEMPT TO ALTER OR MODIFY 

THE CONSTRUCTION OF THE APPLIANCE OR 

ITS COMPONENTS.  ANY MODIFICATION OR 

ALTERATION MAY  VOID THE WARRANTY, 

CERTIFICATION AND LISTINGS OF THIS UNIT.

       WARNING 

Young children should be care-

fully supervised when they are 

in the same room as the appli-

ance. Toddlers, young children 

and others may be susceptible 

to accidental contact burns.  A 

physical barrier is recommended 

if there are at-risk individuals in 

the house.  To restrict access to 

a fireplace or stove, install an 

adjustable safety gate to keep 

toddlers, young children and 

other at-risk individuals out of 

the room and away from hot 

surfaces.

       AVERTISSEMENT 

Les jeunes enfants devraient être 

surveillés étroitement lorsqu’ils 

se trouvent dans la même pièce 

que l’appareil. Les tout petits, 

les jeunes enfants ou les adultes 

peuvent subir des brûlures s’ils 

viennent en contact avec la sur-

face chaude.  Il est recommandé 

d’installer une barrière physique 

si des personnes à risques habi-

tent la maison.  Pour empêcher 

l’accès à un foyer ou à un poêle, 

installez une barrière de sécu-

rité; cette mesure empêchera les 

tout petits, les jeunes enfants et 

toute autre personne à risque 

d’avoir accès à la pièce et aux 

surfaces chaudes.

GENERAL INFORMATION

f i r e - p a r t s . c o m

Содержание Superior Fireplaces MHD40STDMN

Страница 1: ...entretiendoivent treassur spar un installateur ou un service d entretien qualifi ou par le fournisseur de gaz INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future refe...

Страница 2: ...VIDRIO CALIENTE CAUSAR QUEMADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NI OS DEBEN NUNCA TOCAR EL VIDRIO L cran pare tincelles fourni avec ce foyer r duit le risque de br lure en cas de conta...

Страница 3: ...uras graves si se toca Mantenga a los ni os alejados de la chimenea en funcionamiento Supervise en forma cercana a los ni os en cualquier cuarto donde haya una chimenea funcionando para impedir el con...

Страница 4: ...5 oneventrestrictortobeappliedasshownon Page16 restrictoristapedtotheenvelope 6 barriers 7 front face assemblies 8 one fuel conversion kit Nat Gas to LP Gas locatedinthebottomcontrolcompartment NOTE I...

Страница 5: ...odesor in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 latest edition or the Natural Gas and Propane Instal lation Code CAN CGA B149 1 The appliance when installed mu...

Страница 6: ...gas line connector used shall not exceed 36 inches 92 centimeters in length The individual manual shutoff must be a T handle type valve Massachusetts Horizontal Vent Requirements IntheCommonwealthofM...

Страница 7: ...factured Home Construction and Safety Standard Title 24 CPF Part 3280 ou la norme CAN CSA Z240 S rie MM Maisons Mobiles Manufactured Home installations must be installed in accordance with these instr...

Страница 8: ...nt Termination Clearances Terminatemultipleventterminationsaccordingto the installation codes listed above and Figure 3 NOTE See Figure 36 on Page 24 for the exterior wall recess allowances of the squ...

Страница 9: ...de corner 6 152 mm minimum 6 152 mm minimum H Clearance to each inside of center line extended above meter regulator assembly 36 910 mm within a height of 15 ft above the meter regulator assembly 36 9...

Страница 10: ...ppliance face with these exceptions they must not cover any portion of the removable glass panel or control compartment Vertical installation clearances to combustible mantels vary according to the de...

Страница 11: ...loor 0 0 FromBottomof Unit To Ceiling 64 1626 Vent 3 77 Top 1 26 Sides Bottom SERVICE CLEARANCES Feet meters Front Back Sides 3 feet 0 9 meters Table 5 Figure 10 Unit Parts Identification Top View of...

Страница 12: ...provided and bring in the electrical service line Step 6 Page 30 Make connection to gas supply Step7 Page31 Verifyingapplianceoperation Step 8 Page 31 Install the logs decorative volcanic stone and g...

Страница 13: ...his dimension based on 5 8 drywall For 1 2 drywall use 23 Provide Additional Space For Side Vent Seal Cap If Installing Against A Solid Wall 10 1 2 12 1 8 5 1 8 Figure 14 Figure 13 FIREPLACE FRAMING S...

Страница 14: ...40 1 4 1022 41 1041 37 940 34 1 8 867 23 1 2 597 27 3 4 705 23 7 8 607 41 1041 2 51 FRAMING SPACERS Top and both sides FINISHED WALL BRACKET Front and back edge of unit top Stepped to accept drywall o...

Страница 15: ...p 6 on Page 30 Installingagassupplylinefromthefuelsupplyto theapplianceinvolvesnumerousconsiderations of materials protection sizing locations con trols pressure sediment andmore Certainlyno one unfam...

Страница 16: ...exigences du foumisseunde gaz Use only approved venting components See Approved Vent Components on Page 4 These fireplaces must be vented directly to the outside The vent system may not service multip...

Страница 17: ...1 6 0 7 5 2 3 2 5 7 3 9 1 0 0 0 0 5 5 7 3 2 5 7 9 1 1 0 0 0 5 6 5 1 4 2 5 2 1 0 2 0 0 0 7 0 7 6 4 2 5 0 2 1 0 0 7 0 8 2 5 2 1 2 0 1 0 7 0 8 4 6 2 2 2 0 0 1 7 0 8 6 7 2 3 2 0 0 0 8 0 8 9 7 2 5 2 3 2 0...

Страница 18: ...onent to a length of ventrun alignthedimpledendovertheinclined channel end of the previously installed section adjusting the radial alignment until the four locking dimples are aligned with the inlets...

Страница 19: ...8 feet 2 4 m Maximum 1 26 mm minimum clearance to combustibles Figure 24C Another method where the vent is not adjacent toawall isillustratedinFigure24D Here sup portstraps 96K93 andsupportplates 96K9...

Страница 20: ...htheterminationdownuntilitfullyengages thentwisttheterminationclockwiserunningthe dimples down and along the incline channels until they seat at the end of the channels I Install the roof flashing Ext...

Страница 21: ...1 Top Vent TWO 90 DEGREE ELBOWS 40 feet 12 2 meters Maximum uCeiling Firestop Spacer SV4 5VF uWhenusingSecureFlex use Firestop Spacer SF4 5VF uCeiling Firestop Spacer SV4 5VF vWall Firestop Spacer SV4...

Страница 22: ...Firestop Spacer SF4 5VF vWhen using Secure Flex use Firestop Spacer SF4 5HF uCeiling Firestop Spacer SV4 5VF uCeiling Firestop Spacer SV4 5VF vWall Firestop Spacer SV4 5HF Table D H H1 Maximum V Mini...

Страница 23: ...ccurintheceilingorroofjoists Allowforelbows as indicated in Figure 25 on Page 19 Maintain a minimum 1 26 mm clearance to combustiblesontheverticalsections Clearances for the horizontal runs are 3 77 m...

Страница 24: ...articular range of wall thicknesses L Install Firestop Spacer at exterior wall When using the square termination install SV4 5HF Secure Vent SF4 5HF Secure Flex Firestop Spacer over the opening at the...

Страница 25: ...ratios that are smaller are acceptable all the way down to at or near level NOTE SV4 5VF SecureVent SF4 5VF SecureFlex firestop spacermust be used anytime vent pipe passes through a combustible floor...

Страница 26: ...quired ThisTableshowsa1 V to5 H ratio Forevery1 foot of V vertical you are allowed 5 feet of H H1 horizontal run up to a maximum horizontal run of 20 feet Table H H H1 Maximum V Minimum feet meter fee...

Страница 27: ...H1 V1 v Wall Firestop Spacer SV4 5HF uCeiling Firestop Spacer SV4 5VF uCeiling Firestop Spacer SV4 5VF vWall Firestop Spacer SV4 5HF vWall Firestop Spacer SV4 5HF Figure 41 Side Vent THREE 90 DEGREE E...

Страница 28: ...he way 2 ApplyabeadofMill PacBlack 700 F high temperature sealant Catalog No 10K81 to the inner adaptor collar approximately 1 2 from the end 3 Pull and extend the inner flexible vent pipe 4 Slidethei...

Страница 29: ...cancauseimproperanddangerous operation ATTENTION Aumomentdel entretien descommandes tiqueteztouslesfils avant de les d brancher Des erreurs de c blage peuvent entra ner un fonc tionnement inad quat et...

Страница 30: ...is recommended in the gas piping within the home to prevent moisture and debris in the line from damaging the valve These appliances are equipped with a gas flex lineforuse wherepermitted inconnectin...

Страница 31: ...y so that none of the wires become loose or disconnected Step 7 VERIFYING APPLIANCE OPERA TION MILLIVOLT Thermocouple Hood Igniter Rod 3 8 Min 9 mm Thermopile Pilot Nozzels Figure 50 Figure 51 Piezo I...

Страница 32: ...shutter gap should be increased If air shutter is open too far Flame will be blue Air shutter gap should be decreased Sooting is caused by incomplete combustion in the flames and lack of combustion ai...

Страница 33: ...e 53 2 Light appliance follow lighting procedure on lighting label in control compartment or see the Installation and Operation Manual 3 Allow the burner to operate for at least 15 minutes while obser...

Страница 34: ...his Area Must Remain Clear of Combustible Materials 3 77 mm Top Spacers Header Step 11 INSTALL FRONT FACE Install front face assembly with barrier Step 12 HOOD INSTALLATION Refer to Figure 55 All of t...

Страница 35: ...e fonctionnement du foyer en le faisant basculerdeMarche Arr t etvice versa Nettoyez soigneusement la plaque murale de l interrupteur ou le thermostat mural pour liminer la poussi re etlestracesdegrai...

Страница 36: ...ure Vent Components Cat No Model Description H1968 SV4 5HT 2 HorizontalSquareTermina tion With Firestop spacer H2246 Adaptor 74L61 H2152 SV4 5CGV 1 Vertical Termination Cap High Wind Vent Sections Rig...

Страница 37: ...52M H2248 SF4 5HF 10 Firestop Spacer Hori zontal flex 3 1 1spacing 10 Pack H2249 SF4 5VF 10 Firestop Spacer Vertical flex 1 1 1 spacing 10 Pk 56L74 SFVT30 Vertical Termination for flex flat to 6 12 wi...

Страница 38: ...ly so that none of the wires become loose or disconnected d Locate the two 2 latches at the top of the control compartment To disengage the two latches from the bottom vee flange of the glass enclosur...

Страница 39: ...for natural and propane models Figure 59 illustrates the orifice Always check and verify correct orifice size B Install the burner as shown in Figure 60 Ensure that the arm of the venturi of the burn...

Страница 40: ...ter des br luresouqueleursv tements ne s enflamment WARNING Clothing or other flammable material should not be placed on or near the appliance AVERTISSEMENT On ne devrait pas placer de v tements ni d...

Страница 41: ...y to the left away from the fireplace Refer to Figure 62 for access to the gas control valve Millivolt appliances will be fitted with the gas control valve shown in Figure 62 Familiarize yourself with...

Страница 42: ...menea encendi ndola y apag ndola Limpiebienlaplacadelinterruptoro eltermostatodeparedparaquitarelpolvoyaceite Pegue la etiqueta en la superficie de la placa del interruptor que controla la chimenea Fi...

Страница 43: ...aware of shrubs and plantings that may encroach on the termination The appliance and venting system should be thoroughly inspected before initial use and at least annually by a qualified service techn...

Страница 44: ...oors certified with the appliance shall be used Seules des portes certifi es pour cet appareil doivent tre utilis es These are direct vent appliances They are designed to operate only when the front g...

Страница 45: ...Figure 65 Do not use more than is necessary Ensure that the main burner ports remain uncovered by the ember material 5 Place Volcanic Stone Spread volcanic stone evenly over firebox floor 6 Install Ve...

Страница 46: ...ard Against The Grate Here Position Log 2 Over The Grate Bar And Slide It Against The Back Of The Grate Here Position Groove At The Bottom Of Log 2 Over The Grate Here And Slide It Against The Back Of...

Страница 47: ...1 3 Figure 67 3 Grate Assembly 5 Position Small End Of Log 6 On The Notch Of Log 3 Here 6 4 Position The Round End Of Log 6 Against The Notch Of Log 4 Here Two Charred Spots Face The Front Position Th...

Страница 48: ...shutter opening will need to be An appliance operated with the air shutter opened too far may have flames that appear blue and transparent These weak blue and transparent flames are termed anemic Prop...

Страница 49: ...parts always give the following information 1 The model number of the appliance 2 The serial number of the appliance 3 The part number 4 The description of the part 5 The quantity required 6 The inst...

Страница 50: ...wall mounted or placed in the valve compartment Wall Thermostat Wall surface mounted Thermostat or manual ON OFF operation Large LCD screen to display room and set temperature in F and C Connects to...

Страница 51: ...er Kits Cat No Model No Description H0778 EBLK PF MHD40PF H0779 EBLK ST MHD40ST OFF ON Wall Switch Kit TheOFF ONwallswitchkitmaybeusedtocontrolthe operation of the fireplace burner Install the OFF ON...

Страница 52: ...used by long lateral runs too many elbows and or exterior portions of the systembeingexposedtocoldweather Alsoinspectwallstraps or plumbers s tape to ensure it is secure and in place Appliance Checkou...

Страница 53: ...immediately call your service technician or gas supplier LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE If the pilot will not stay lit after several tries turn the gas control knob to OFF and call...

Страница 54: ...imm diatement un technicien qualifi ou le fournisseur de gaz Si la veilleuse ne reste pas allum e apr s plusieurs tentatives r glez la manette d admission du gaz la position OFF et appelez un technic...

Страница 55: ...shooting should only be accomplished by a qualified service technician Clean and or adjust pilot flame for maximum flame impinge ment on thermocouple Figure 50 on Page 31 Check burner orifice for stop...

Страница 56: ...Face Assembly with Barrier J7531 0 1 WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in proper...

Страница 57: ...or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard c damage...

Страница 58: ...Date fireplace was Installed Type of gas fireplace uses Dealer name Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices a...

Отзывы: