background image

SuperiorFireplaces.us.com

126631-01_H

12

EFFECTIVE HEIGHT

OF TERMINETION CAP 

EFFECTIVE HEIGHT

OF TERMINETION CAP 

EFFECTIVE HEIGHT

OF TERMINETION CAP 

EFFECTIVE HEIGHT

OF TERMINETION CAP 

14.5 FT 

(4.42 m)

MINIMUM 

HEIGHT

30E-8DM

30E-8DM

UP TO 

6 FT (1.83 m)

MAX.

UP TO 

6 FT (1.83 m)

MAX.

14.5 FT 

(4.42 m)

MINIMUM 

HEIGHT

MAX. HEIGHT

50 FT (15.24 m)

ANY SYSTEM

MIN. HEIGHT

22 FT (6.71 m)

WITH 2 ELBOW SETS

MAX. HEIGHT 

OF 50 FT. (15.24 m)

VENTING INSTALLATION  

Continued

CHASE INSTALLATIONS

Instructions for chase installations are included with chase style ter-

mination chosen. In a multiple chase installation, be sure to provide 

adequate distance between terminations to prevent smoke spillage 

from one termination to another. We suggest that terminations be 

separated at least 24", center to center and stacked at a vertical height 

difference of 18" (see Figure 18).

Note:

 If a decorative shroud is to be installed, contact manufacturer 

for specifications.

Figure 18 - Multiple Chase Installation

10

'

(3.05 m) 

10

'

(3.05 m) 

2

(0.61 m)

Min.

2

(0.61 m) Min.

3

(0.92 m)

Min.

3

(0.92 m)

Min.

Level of 

Flue Gas Outlet 

Figure 19 - 10 Foot Rule

10 FOOT RULE

All flue gas outlet chimney terminations must extend a minimum of 

3 feet in height above highest point where it passes through roof and 

must be at least 2 feet above highest point of the roof that is within 

a horizontal distance of 10 feet (see Figure 19).

FINISHING FIREPLACE

Combustible materials, such as wallboard, sheet rock, drywall, ply-

wood, etc., may make direct contact with sides and top around fire-

place face. It is important that combustible materials do not overlap 

face itself. Brick, glass, tile or other noncombustible materials may 

overlap front face provided they do not obstruct essential openings 

such as louvered slots. When overlapping with a noncombustible 

facing material, use only noncombustible mortar or adhesive.

Figure 20 - Typical Residential Installations

24" (610 mm)Min.

24" (610 mm)Min.

18" 

(458 mm)

Min. Typ.

Содержание Superior Fireplaces Merit WRT2042WS

Страница 1: ...CANADA The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to determine the need to obtain a permit POUR LE CANADA L...

Страница 2: ...ufactured or approved by IHP in combination with an IHP fireplace system Proper installation is the most important step in ensuring safe and continuous operation of the fireplace Consult the local bui...

Страница 3: ...oseasignificanthazard IMPORTANT See appendix A page 21 for additional information regarding draft requirements smoking causes and troubleshooting WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESULT...

Страница 4: ...LL BOARD NOT LESS THAN 12 305 mm TO PERPENDICULAR SIDEWALL 0 0 MM TO BOTTOM 12 305 mm EACH SIDE GAS LINE KNOCK OUT GAS LINE KNOCK OUT RIGHT SIDE LEFT SIDE AIR KIT KNOCK OUT 8 1 4 210 mm 8 1 4 210 mm 2...

Страница 5: ...ling flanges touch side framing 4 Check level of fireplace and shim with sheet metal if necessary 5 Before securing fireplace to prepared framing ember protector must be placed between hearth extensio...

Страница 6: ...top opening of fireplace NFPA 211 Section Clearance from Combustible Material Mantels or any other combustible material may come up to side edge of black metal face of fireplace if projection from fro...

Страница 7: ...r through a sidewall AK4 See Figure 7 for instruction of operating air kit CAUTION Combustion air inlet ducts shall not terminate in attic space The maximum height for the air vent can not exceed 3 fe...

Страница 8: ...above 20 feet must be supported USING ELBOW OFFSETS 30E 8DM 1 To achieve desired offset you may install combinations of 12 18 24 36 and 48 length of double wall pipe see offset chart page 9 and Figure...

Страница 9: ...bow Return Elbow Return Elbow Return Elbow Return Elbow Offset Elbow Offset Elbow Offset Elbow Offset Elbow Offset Elbow 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m C...

Страница 10: ...oftheroof Pitchisthedistancetheroofdrops overagivenspan usually12 A6 12pitchmeansthattheroofdrops 6 for each 12 measure horizontally down from roof rafters 3 Use roof opening chart Figure 14 page 11 t...

Страница 11: ...stor Fireplace system must be terminated with listed round top or chase terminations In any case refer to installation instructions supplied with termination Terminations approved for this fireplace a...

Страница 12: ...shroud is to be installed contact manufacturer for specifications Figure 18 Multiple Chase Installation 10 3 05 m 10 3 05 m 2 0 61 m Min 2 0 61 m Min 3 0 92 m Min 3 0 92 m Min Level of Flue Gas Outle...

Страница 13: ...ment Install gas appliance or cap off gas line if desired CAUTION All gas piping and connections must be tested for leaks after installation is completed After ensuring that gas valve is on apply soap...

Страница 14: ...ireplace with glass doors has a limited amount of air for combustion Excessive heat within fireplace can result if too large a fire is built or if combustion air gate is not completely open The follow...

Страница 15: ...used if installed in accordance with the instructions by its manufacturer A locally fabricated shroud may be used with IHP Shroud Leg Spacer Kit SLK in accor dance with instructions provided with the...

Страница 16: ...16 PARTS WOOD BURNING FIREPLACE MODELS WRT2042WS WRT2042WSI WCT2042WS WCT2042WSI MODEL CAT NO WRT2042WS F0687 WRT2042WSI F0688 WCT2042WS F0689 WCT2042WSI F0690 11 27 23 23 22 24 10 14 25 4 17 3 2 1 18...

Страница 17: ...ly 1 8 Firebox Floor 1 9 Wrapper Bottom 1 10 Front Face Weldment Smooth 1 Front Face Weldment Louvered 1 11 See Page 18 Left Side Brick Liner 1 12 See Page 18 Rear Brick Liner 1 13 See Page 18 Right S...

Страница 18: ...IHP dealer to obtain any of these parts Never use substitute materials not ap proved by IHP Use of non approved parts can result in poor performance and safety hazards 1 2 4 3 6 5 REFRACTORY STAIN KIT...

Страница 19: ...T 18 Section Hi Temp Double Wall Pipe Snap Lock F0883 24 8HT 24 Section Hi Temp Double Wall Pipe Snap Lock F0884 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Do...

Страница 20: ...UVERS AND SLIP SECTION F0921 ETL 8DM Square Top with Slip Section F0893 ETL 8HT Hi Temp Large Pyramid Top with Slip Section MESH SQUARE TOP TERMINATION F0922 ETO 8DM Square Top with Mesh MESH SQUARE T...

Страница 21: ...nditions inadequate chimney heights adversewindconditionsand orunusualenvironmental factors or conditions beyond our control take into account all variables within the installation and install the app...

Страница 22: ...ance The best location to install your appliance is determined by consid ering the location of windows doors and the traffic flow in the room where the appliance is located allowing space in front of...

Страница 23: ...be subject to normal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with a...

Страница 24: ...6631 01 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult yo...

Отзывы: