IHP Superior Fireplaces Merit WCT2042WS Скачать руководство пользователя страница 14

SuperiorFireplaces.us.com

126631-01_H

14

Figure 23 - Glass Doors

Figure 24 - Damper Handle Location

Cleaning Glass

Clean glass with any commercial glass cleaner or soap and water. 

Do not use any abrasive material to clean the glass. Do not clean 

glass with any cool water if glass is still hot from fire and smoke.

DAMPER HANDLE OPERATION

Damper handle, which opens and closes damper blade, is located 

inside firebox at center towards back wall (see Figure 24). Pushing 

handle back into keyway slot will free damper blade to automatically 

open. To close, push handle back into keyhole slot then pull down 

and forward to lock it in place (see Figure 25).Vent damper must be 

locked in the full open position before operating fireplace.

 WARNING: Risk of fire! Replace grate with IHP 

model 107001-02 only. This grate has been designed to 

keep the operation of your fireplace safe and efficient.

OPERATION AND MAINTENANCE

Figure 25 - Damper Rod

Doors Fully Closed

Doors Fully Opened

Fireplace Front

Fireplace Front

GLASS DOORS

Glass doors are optional with this fireplace. When fireplace is in 

operation, doors must be fully opened or fully closed position only 

or a fire hazard may be created (see Figure 23).
A fireplace equipped with glass doors operates much differently than 

a fireplace with an open front. A fireplace with glass doors has a 

limited amount of air for combustion. Excessive heat within fireplace 

can result if too large a fire is built or if combustion air gate is not 

completely open.
The following tips should be used to assure that both fireplace and 

glass door retain their beauty and function properly. Both the flue 

damper and glass doors must be fully opened before starting a 

fire. This will provide sufficient combustion air and maintain safe 

temperatures in firebox.

IMPORTANT: 

The glass must be allowed to warm slowly and evenly. 

Tempered glass will withstand a gradual temperature rise to 550° 

F, which is more than a normal fire will generate. Such materials as 

pitch/wax laden logs, very dry mill end lumber and large amounts 

of paper or cardboard boxes can create an excessively hot fire and 

should not be burned in this fireplace. Always keep fire back from 

doors and never allow flames to contact glass.

  WARNING: FIREPLACES EQUIPPED WITH DOORS 

SHOULD BE OPERATED ONLY WITH DOORS FULLY 

OPEN OR DOORS FULLY CLOSED. IF DOORS ARE 

LEFT PARTLY OPEN, GAS AND FLAME MAY BE 

DRAWN OUT OF THE FIREPLACE OPENING, CREAT-

ING RISKS OF BOTH FIRE AND SMOKE.

 WARNING: Discontinue use of the appliance 

immediately if doors are damaged and contact a 

qualified installer for repair. Only doors certified 

with the appliance shall be used.

 WARNING: Do not slam or strike doors. Damage 

can result in a hazardous condition.

Damper 

Handle

1

2

3

1

2

3

Damper 

Weight

To Close Damper

To Open Damper

Содержание Superior Fireplaces Merit WCT2042WS

Страница 1: ...ANADA The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to determine the need to obtain a permit POUR LE CANADA L autorité compétente comme le service municipal du bâtiment les pompiers etc doit être contacté avant l installation afin de déterminer la nécessité d obtenir un permis This appliance may be installed ...

Страница 2: ...nufactured or approved by IHP in combination with an IHP fireplace system Proper installation is the most important step in ensuring safe and continuous operation of the fireplace Consult the local building codes as to the particular requirements concerned with the installation of all factory built fireplaces WARNING Do not install a fireplace insert in this fireplace unless the manufacturer s ins...

Страница 3: ...poseasignificanthazard IMPORTANT See appendix A page 21 for additional information regarding draft requirements smoking causes and troubleshooting WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESULT IN CARBON MONOXIDE POISONING WHICH MAY LEAD TO DEATH Carbon Monoxide Poisoning Early signs of carbon monoxidepoisoningresemblethefluwithheadaches dizziness or nausea If you have these signs get fresh...

Страница 4: ...ALL BOARD NOT LESS THAN 12 305 mm TO PERPENDICULAR SIDEWALL 0 0 MM TO BOTTOM 12 305 mm EACH SIDE GAS LINE KNOCK OUT GAS LINE KNOCK OUT RIGHT SIDE LEFT SIDE AIR KIT KNOCK OUT 8 1 4 210 mm 8 1 4 210 mm 25 3 8 645 mm 14 1 2 369 mm 38 7 8 988 mm 1 3 8 35 mm 1 3 4 45 mm 1 26 mm 1 26 mm 32 813 mm 28 1 2 724 mm 21 1 8 537 mm 5 8 16 mm 14 356 mm 44 1118 mm 44 1118 mm 42 1067 mm 7 178 mm 7 178 mm 13 331 mm...

Страница 5: ...iling flanges touch side framing 4 Check level of fireplace and shim with sheet metal if necessary 5 Before securing fireplace to prepared framing ember protector must be placed between hearth extension not included and under bottom front edge of fireplace to protect against glowing embers falling through If fireplace is to be installed on a raised platform a Z type ember protector not included mu...

Страница 6: ... top opening of fireplace NFPA 211 Section Clearance from Combustible Material Mantels or any other combustible material may come up to side edge of black metal face of fireplace if projection from front face falls within limits shown in Figure 5 33 12 1 4 312 mm Ref 1 1 2 39 mm Max 6 153 mm Ref 9 229 mm Min 12 305 mm Min 15 381 mm Min 3 77 mm Nom Combustible Material Safe Zone For Projection of C...

Страница 7: ...or through a sidewall AK4 See Figure 7 for instruction of operating air kit CAUTION Combustion air inlet ducts shall not terminate in attic space The maximum height for the air vent can not exceed 3 feet below the flue gas outlet of the termination CHIMNEY PIPE WARNING Label part number 900599 01 must be applied by the installer to all chimney pipe sections but is not required on sections that wil...

Страница 8: ... above 20 feet must be supported USING ELBOW OFFSETS 30E 8DM 1 To achieve desired offset you may install combinations of 12 18 24 36 and 48 length of double wall pipe see offset chart page 9 and Figure 9 page 8 Note For systems with 2 elbow sets minimum height is 22 feet Maximum height for any system is 50 feet 2 Chimney weight above offset rests on return elbow Straps must be securely nailed to r...

Страница 9: ...lbow Return Elbow Return Elbow Return Elbow Return Elbow Offset Elbow Offset Elbow Offset Elbow Offset Elbow Offset Elbow 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m Ceiling Support Pipe 12S 8DM Ceiling Support Pipe 12S 8DM 2 Min Straps Straps Straps Straps Detail A Return Elbow Detail B Angle Firestop See Detail A See Detail B ...

Страница 10: ...toftheroof Pitchisthedistancetheroofdrops overagivenspan usually12 A6 12pitchmeansthattheroofdrops 6 for each 12 measure horizontally down from roof rafters 3 Use roof opening chart Figure 14 page 11 to determine correct opening length and flashing required 4 Remove shingles around opening measured Cut out this section 5 Add next sections of pipe until end penetrates roof line Check to see that pr...

Страница 11: ...estor Fireplace system must be terminated with listed round top or chase terminations In any case refer to installation instructions supplied with termination Terminations approved for this fireplace are RT 8DM and RLT 8DM that can be used for flashing or chase and ET 8DM ETO 8DM ETL 8DM and ETLO 8DM for chase style termination only Figure 17 shows an RLT 8DM round top termination CAUTION Do not s...

Страница 12: ...e shroud is to be installed contact manufacturer for specifications Figure 18 Multiple Chase Installation 10 3 05 m 10 3 05 m 2 0 61 m Min 2 0 61 m Min 3 0 92 m Min 3 0 92 m Min Level of Flue Gas Outlet Figure 19 10 Foot Rule 10 FOOT RULE All flue gas outlet chimney terminations must extend a minimum of 3 feet in height above highest point where it passes through roof and must be at least 2 feet a...

Страница 13: ...ement Install gas appliance or cap off gas line if desired CAUTION All gas piping and connections must be tested for leaks after installation is completed After ensuring that gas valve is on apply soap and water solution to all connections and joints Bubbles forming show a leak Correct all leaks at once DO NOT USE AN OPEN FLAME FOR LEAK TESTING AND DO NOT OPERATE ANY APPLIANCE IF A LEAK IS DETECTE...

Страница 14: ...fireplace with glass doors has a limited amount of air for combustion Excessive heat within fireplace can result if too large a fire is built or if combustion air gate is not completely open The following tips should be used to assure that both fireplace and glass door retain their beauty and function properly Both the flue damper and glass doors must be fully opened before starting a fire This wi...

Страница 15: ...e used if installed in accordance with the instructions by its manufacturer A locally fabricated shroud may be used with IHP Shroud Leg Spacer Kit SLK in accor dance with instructions provided with the shroud NOTICE The firebox canopy hood must not be modified or replaced with a canopy that may be provided with the unvented decorative room heater CAUTION THE STRUCTURAL INTEGRITY OF THE MANU FACTUR...

Страница 16: ... 16 PARTS WOOD BURNING FIREPLACE MODELS WRT2042WS WRT2042WSI WCT2042WS WCT2042WSI MODEL CAT NO WRT2042WS F0687 WRT2042WSI F0688 WCT2042WS F0689 WCT2042WSI F0690 11 27 23 23 22 24 10 14 25 4 17 3 2 1 18 5 20 28 12 7 15 9 16 13 8 26 6 19 21 ...

Страница 17: ...bly 1 8 Firebox Floor 1 9 Wrapper Bottom 1 10 Front Face Weldment Smooth 1 Front Face Weldment Louvered 1 11 See Page 18 Left Side Brick Liner 1 12 See Page 18 Rear Brick Liner 1 13 See Page 18 Right Side Brick Liner 1 14 See Page 18 Bottom Brick Liner 1 15 See Page 18 Front Bottom Brick Liner 1 16 J6937 Blower Access Plate 1 17 J6895 Refractory Retainer 2 18 Circulation Plate 1 19 Insulation Reta...

Страница 18: ... IHP dealer to obtain any of these parts Never use substitute materials not ap proved by IHP Use of non approved parts can result in poor performance and safety hazards 1 2 4 3 6 5 REFRACTORY STAIN KITS Use the refractory stain kits to give white refractory panels a new look Kit includes foam roller handle paint tray and one can of stain Available stain colors are creamer ivory Rust terra cotta an...

Страница 19: ...HT 18 Section Hi Temp Double Wall Pipe Snap Lock F0883 24 8HT 24 Section Hi Temp Double Wall Pipe Snap Lock F0884 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Double Wall Pipe Snap Lock 30 OFFSET AND RETURN F0900 30E 8DM 30 Degree Offset and Return F0886 30E 8HT 30 Degree Hi Temp Offset and Return OPTIONAL OUTSIDE AIR KIT FOR SIDEWALL INSTALLATION F1091 AK4 ...

Страница 20: ...OUVERS AND SLIP SECTION F0921 ETL 8DM Square Top with Slip Section F0893 ETL 8HT Hi Temp Large Pyramid Top with Slip Section MESH SQUARE TOP TERMINATION F0922 ETO 8DM Square Top with Mesh MESH SQUARE TOP TERMINATION WITH SLIP SECTION F0923 ETLO 8DM Square Top with Mesh and Slip Section ADJUSTABLE HOOD Required when installing a vent free gas log in this fireplace F1764 GA6050 Black Fireplace Hood ...

Страница 21: ...onditions inadequate chimney heights adversewindconditionsand orunusualenvironmental factors or conditions beyond our control take into account all variables within the installation and install the appliance in such a manner that satisfies the draft requirements of the appliance See Chimney Guidelines to assist you in selecting the proper venting system for your installation American National Stan...

Страница 22: ...iance The best location to install your appliance is determined by consid ering the location of windows doors and the traffic flow in the room where the appliance is located allowing space in front of the unit for the hearth extension and the mantel and taking into consideration the location of the hot air ducts some models outside air kit and chimney Ifpossible youshouldchoosealocationwherethechi...

Страница 23: ... be subject to normal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with abnormal burning characteristics including but not limited to fuel such as driftwood coal or plywood and wood products using a binder may burn at excessive temperatures and may cause damage to the Pro...

Страница 24: ...26631 01 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information Printed in U S A 2013 Innovative Hearth Products LLC P N 126631 01 Rev H 01 2019 1769 East Lawrence Street Russellville AL 35654 ...

Отзывы: