IHP GA9050A-1 Скачать руководство пользователя страница 1

Save this manual for future reference.

The GA9050A-1 Series Manual On/Off Safety Valve/Pilot kit contains the following:

• Piezo Ignitor 

 

 

097159-04

• Manual Valve 

 

 

901068-02

• Pilot Burner (with natural gas orifice)  

 

901069-03

• Piezo Ignitor Electrode 

 

 

901072-01

• Steel Shroud - Pilot Kit 

 

 

901139-01

• Pilot Kit Incidentals 

 

 

901152-01

• Control Dial Instructions 

 

 

901042-01

• Brass 3/8 FLR x 3/8 MPT Elbow 

 

 

14264

• 18" Propane/LP Brass Orifice 

 

 

901065-02

• 24" Propane/LP Brass Orifice 

 

 

901065-03

• 30" Propane/LP Brass Orifice 

 

 

901065-04

• Propane/LP Brass Air Mixer 

 

 

901066-02

• Propane/LP Pilot Burner Orifice 

 

 

901070-01

• Screw 1/4" #8 “B” pt (4 ea.) 

 

 

901075-01

• Pilot Valve Control Dial 

 

 

901079-01

• Pilot Valve Dial Extension 3" 

 

 

901080-01

• Propane Conversion Decal 

 

 

901691-01

P126905-01

INSTALLATION INSTRUCTIONS

MANUAL ON/OFF SAFETY VALVE/PILOT KIT

MODEL GA9050A-1 (F0235)

For All Single, Dual and Triple Burner Natural 

and Propane/LP Gas Logs

 WARNING: 

FIRE OR EXPLOSION HAZARD 
Failure to follow safety warnings exactly could result in serious injury, death, or property damage.

—  Installation and service must be performed by a qualified installer, service agency, or the gas 

supplier.

 WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause injury or 

property damage. Refer to this manual for correct installation and operational procedures. For assistance 

or additional information consult a qualified installer, service agency, or the gas supplier.

For more information, visit IHP.US.com

P/N  126905-01   Rev.  B  11/2016

f i r e - p a r t s . c o m

Содержание GA9050A-1

Страница 1: ...01 Pilot Valve Dial Extension 3 901080 01 Propane Conversion Decal 901691 01 P126905 01 INSTALLATION INSTRUCTIONS MANUALON OFFSAFETYVALVE PILOTKIT MODEL GA9050A 1 F0235 For All Single Dual and Triple Burner Natural and Propane LP Gas Logs WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage Installation and service must ...

Страница 2: ...iple Burner 65 000 55 000 8 dia BFLT24 24 Triple Burner 70 000 60 000 8 dia Add 6 if safety valve pilot is used At depth indicated FUEL INLET PRESSURE SPECIFICATIONS W C Gas Min Max NG 5 5 10 5 LP 11 13 BURNER ORIFICE NATURAL PROPANE LP LOG SIZE IN NUM CLR IN NUM CLR 18SR DR 0 120 31 Blue 0 073 49 Red 24SR DR BFLT18 0 129 30 Green 0 086 44 Orange 30DR BFLT24 0 1405 28 Yellow 0 089 43 Black MINIMUM...

Страница 3: ...th the vent pointing down as shown in Figure 2 Pointing the vent down protects it from freezing rain or sleet WARNING Never connect natural gas appliance to private non utility gas wells This gas is com monly known as wellhead gas CAUTION Use only new black iron or steel pipe Internally tinnedcoppertubingmaybeusedincertain areas Check your local codes Use pipe of 1 2 diam eter or greater to allow ...

Страница 4: ...nected 3 Pressurize supply piping system by either opening propane LP supply tank valve for propane LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air 4 Check all joints of gas supply piping system Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak 5 Correct all leaks at once 6 Reconnect log set and equipment shutoff...

Страница 5: ...low Adjustment Screw Figure 9 Installing Inlet Fitting and Gas Connector Tube Gas Control Valve Gas Inlet Fitting Gas Connector Tube Inlet Opening INSTALLATION Continued Figure 10 Installing Cover Control Knob and Piezo Ignitor Piezo Ignitor Control Rod Extension Screw Valve Cover Control Knob Thermocouple Ignitor Pilot 5 Thread the gas supply adaptor to the fireplace gas supply pipe Adjust to mos...

Страница 6: ...LOW ADJUSTMENT After installation is complete and the unit has been ignited it may be necessary to adjust the pilot Use a small flat head screwdriver to turn the flow adjustment screw on the manual control valve see Figure 14 Turn the screw counterclockwise to allow more gas to flow or clockwise to restrict gas flow Be careful to limit the turns to 2 1 2 from the fully closed position Further turn...

Страница 7: ...es not stay lit contact a qualified service person or gas supplier for repairs Until repairs are made light pilot with match 7 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release control knob Note If pilot goes out repeat steps 3 through 7 If control knob does not pop up when released contact a qualified service person or gas supplier for repairs 8 Turn contro...

Страница 8: ...e in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information Printed in U S A 2014 Innovative Hearth Products LLC P N 126905 01 Rev B 11 2016 1508 Elm Hill Pike Suite 108 Nashville TN 37210 fire parts com ...