VENTING INSTALLATION 

Continued

ASSEMBLY AND INSTALLATION OF DOUBLE WALL CHIMNEY 

SYSTEM

SS-8DM starter section must be installed first.

Each double wall chimney section consists of a galvanized outer 

pipe, a stainless steel inner flue pipe and a wire spacer. Pipe sections 

must be assembled independently as chimney is installed. When 

connecting chimney directly to fireplace, inner flue pipe section 

must be installed first with lanced side up. Outer pipe section can 

then be installed over flue pipe section with hemmed end up. Press 

down on each pipe section until lances securely engage hem on 

fireplace starter. Wire will assure proper spacing between inner 

and outer pipe sections.

Note:

 For Canada, use chimney parts designated HT.

 Opening in collar around chimney at top of 

fireplace must not be obstructed. Never use blown 

insulation to fill chimney enclosure.

Continue to assemble chimney sections as outlined, making sure 

that both inner and outer pipe sections are locked together. When 

installing double wall snap-lock chimney together, it is important to 

assure joint between chimney sections is locked. Check by pulling 

chimney upward after locking. Chimney will not come apart if properly 

locked. It is not necessary to add screws to keep chimney together 

(exception - see Figure 7).

The height of a vertical chimney pipe supported 

ONLY

 by the 

fireplace, must not exceed 20 feet. Chimney heights above 20 feet 

must be supported.

USING ELBOW OFFSET 30E-12DMO-8DMR

To clear overhead obstructions, you may offset your chimney system 

using 

30E-12DMO-8DMR 30° Offset/return elbow.

A section or sections of chimney may be used between offsets and 

return elbow. Transition pipe must be used after elbow offset is 

attached.
1.  To achieve desired offset, you may install combinations of 12", 

18", 24", 36" and 48" length of double wall pipe (see offset chart).

 

Note:

 For systems with 2 elbow sets, minimum height is 22 feet. 

Maximum height for any system is 50 feet.

2.  Chimney weight above offset rests on return elbow. Straps must 

be securely nailed to rafters or joists (see Figure 9 details A and 

B, page 9).

3.  Maximum length of pipe between supports (return elbow or 12S-

8DM) is 6' of angle run. Maximum of two 6' angle run sections 

per chimney system (see Figure 8, page 9).

4.  All pipe connections between offset and return must be secured 

with two screws on outer pipe only (see Figure 7). Do not pen

-

etrate inner stainless.

Figure 7 - Elbow Offset

OFFSET CHART WITH TRANSITION PIPE

OFFSET

RISE

OFFSET/

RETURN 

ELBOW

TRANSITION 

PIPE

CHIMNEY LENGTH

A

B

12"

18"

36"

48"

13 

3

/

4

"

32 

1

/

2

"

1

1

19"

41"

1

1

1

1

22"

46 

3

/

4

"

1

1

1

24 

1

/

2

"

50 

3

/

4

"

1

1

2

27 

1

/

2

"

56

1

1

1

1

30 

1

/

4

"

61

1

1

2

31

62 

1

/

2

"

1

1

1

32 

1

/

2

"

65"

1

1

2

1

35 

1

/

2

"

70 

1

/

4

"

1

1

1

2

36 

1

/

4

"

71 

1

/

2

"

1

1

1

1

37

72 

3

/

4

"

1

1

1

38 

1

/

2

"

75 

1

/

2

"

1

1

3

39 

1

/

4

"

76 

3

/

4

"

1

1

1

1

41 

1

/

2

"

80 

1

/

2

"

1

1

2

1

42 

1

/

4

"

81 

3

/

4

"

1

1

1

1

44 

1

/

2

"

85 

3

/

4

"

1

1

1

1

1

45 

1

/

4

"

87"

1

1

1

1

47 

1

/

2

"

91"

1

1

2

1

48 

1

/

4

"

92 

1

/

4

"

1

1

2

49 

3

/

4

"

94 

3

/

4

"

1

1

2

1

1

52"

98 

3

/

4

"

1

1

1

4

53 

1

/

2

"

101 

1

/

4

"

1

1

1

2

54 

1

/

4

"

102 

3

/

4

"

1

1

1

1

55 

3

/

4

"

105 

1

/

4

"

1

1

3

1

56 

1

/

2

"

106

1

/

2

"

1

1

1

2

58 

3

/

4

"

110 

1

/

2

"

1

1

2

2

59 

1

/

2

"

111 

3

/

4

"

1

1

1

1

1

60 

1

/

4

"

113"

1

1

2

61 

3

/

4

"

115 

3

/

4

"

1

1

1

1

2

64 

3

/

4

"

120 

3

/

4

"

1

1

2

2

65 

1

/

2

"

122 

1

/

4

"

1

1

1

2

67"

124 

3

/

4

"

1

1

2

1

2

B

A

Screws

Содержание Comfortflame Shiloh42RWS

Страница 1: ...re installation to determine the need to obtain a permit POUR LE CANADA L autorité compétente comme le service municipal du bâtiment les pompiers etc doit être contacté avant l installation afin de déterminer la nécessité d obtenir un permis This appliance may be installed in an aftermarket permanently located manufactured home USA only or mobile home where not prohibited by local codes This appli...

Страница 2: ...y component part not manufactured or approved by IHP in combination with an IHP fireplace system Proper installation is the most important step in ensuring safe and continuous operation of the fireplace Consult the local building codes as to the particular requirements concerned with the installation of all factory built fireplaces WARNING Do not install a fireplace insert in this fireplace unless...

Страница 3: ...sed to treat insects and fungus When burned thesechemicalscanposeasignificanthazard WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESULT IN CARBON MONOXIDE POISONING WHICH MAY LEAD TO DEATH Carbon Monoxide Poisoning Early signs of carbon monoxidepoisoningresemblethefluwithheadaches dizziness or nausea If you have these signs get fresh air at once Have the appliance inspected by a qualified servic...

Страница 4: ...COMBUSTIBLE WALL BOARD TOP SPACERS 0 TO 1 AIRSPACE TO COMBUSTIBLE MATERIAL NO COMBUSTIBLE MATERIAL ON FACE NO COMBUSTIBLE MATERIAL BELOW TOP SPACERS GAS LINE KNOCK OUT AIR KIT KNOCK OUTS GAS LINE STARTER SECTION 8DM PIPE INNER DIA OUTER DIA 15 KNOCK OUTS ELECTRICAL OUTLET LEFT SIDE RIGHT SIDE PERPENDICULAR NOT LESS THAN 12 TO SIDEWALL 41 48 42 8 39 12 48 36 24 8 1 8 10 5 8 12 5 8 10 5 8 6 3 4 14 1...

Страница 5: ...Chimney Height for Outdoor Installation The minimum height of the chimney measured from the base of the fireplace to the flue gas outlet of the termination is 8 feet minimum of 4 feet of chimney pipe sections required for outdoor installation Figure 2 Corner Installation FRAMING 1 Frame opening for fireplace using dimensions shown in Figures 1 and 2 Note When the fireplace is framed the header has...

Страница 6: ... Combustible Materials Fireplace Opening Non Combustible Materials Below Top Spacer Upper Section of Fireplace DRAIN PAN DP42 For outdoor installations the fireplace enclosure must allow for adequate drainage and fresh air ventilation It is recommended that a sealed corrosion resistant catch pan with provision for drainage be installed under the fireplace within the fireplace enclosure see Accesso...

Страница 7: ...of 12 18 24 36 and 48 snap lock double wall pipe segments planned for maximum adaptability to individual site requirements Actual lengths gained after fitting overlaps must be taken into consideration lineal gain and are given in lineal gain chart see Figure 6 Lineal gain is actual measurable length of a part after two or more parts are connected Figure 6 Lineal Gain Hemmed End 8 Stainless Inner P...

Страница 8: ...ad obstructions you may offset your chimney system using 30E 12DMO 8DMR 30 Offset return elbow A section or sections of chimney may be used between offsets and return elbow Transition pipe must be used after elbow offset is attached 1 To achieve desired offset you may install combinations of 12 18 24 36 and 48 length of double wall pipe see offset chart Note For systems with 2 elbow sets minimum h...

Страница 9: ...tinued Figure 8 Typical Offset Installation 30E 8DM Return Elbow 30E 8DM Return Elbow 30E 8DM Offset Elbow 30E 8DM Offset Elbow 30E 12DMO 8DMR Offset Elbow 30E 12DMO 8DMR Offset Elbow 30E 12DMO 8DMR Offset Elbow 30E 12DMO 8DMR Return Elbow 30E 12DMO 8DMR Return Elbow 30E 12DMO 8DMR Return Elbow Starter Section Starter Section Starter Section 6 Max 8 DM Pipe 8 DM Pipe 6 Max 6 Max 6 Max 6 Max 6 Max ...

Страница 10: ... center point where pipe will penetrate the roof 2 Determine center point of the roof Pitch is the distance the roof drops over a given span usually 12 A 6 12 pitch means that the roof drops 6 for each 12 measure horizontally down from roof rafters 3 Use roof opening chart Figure 12 page 11 to determine correct opening length and flashing required 4 Remove shingles around opening measured Cut out ...

Страница 11: ...l it is snug against open edge of flashing see Figure 14 Use SC1 for all round termina tions Apply waterproof caulk around perimeter of collar to provide a proper seal Figure 14 Storm Collar Chimney Pipe Waterproof Caulk Storm Collar Flashing Terminations Spark Arrestor Fireplace system must be terminated with listed round top or chase terminations In any case refer to installation instructions su...

Страница 12: ...center and stacked at a vertical height difference of 18 see Figure 16 Note If a decorative shroud is to be installed contact manufacturer for specifications 24 Min 24 Min 18 Min Figure 16 Multiple Chase Installation 10 2 Min 10 3 Min 2 Min 3 Min Level of Flue Gas Outlet Figure 17 10 Foot Rule 10 FOOT RULE All flue gas outlet chimney terminations must extend a minimum of 3 feet in height above hig...

Страница 13: ...ement Install gas appliance or cap off gas line if desired CAUTION All gas piping and connections must be tested for leaks after installation is completed After ensuring that gas valve is on apply soap and water solutiontoallconnectionsandjoints Bubblesforming show a leak Correct all leaks at once DO NOT USE AN OPEN FLAME FOR LEAK TESTING AND DO NOT OPERATE ANY APPLIANCE IF A LEAK IS DETECTED LEAK...

Страница 14: ...eplace Front Fireplace Front GLASS DOORS Glass doors are optional with this fireplace When fireplace is in operation doors must be fully opened or fully closed position only or a fire hazard may be created see Figure 21 A fireplace equipped with glass doors operates much differently than a fireplace with an open front A fireplace with glass doors has a limited amount of air for combustion Excessiv...

Страница 15: ...plied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the fireplace 2 The serial number of the fireplace 3 The part number 4 The description of the part 5 The quantity required 6 The installation date of...

Страница 16: ...Comfortflame US com 900574 00N C 16 9 24 16 31 25 16 4 30 32 19 12 23 20 28 17 8 1 5 21 2 18 11 14 3 13 22 10 6 35 29 7 33 34 26 27 15 PARTS Model Shiloh42RWS MODEL NO CATALOG NO Shiloh42RWS F2555 ...

Страница 17: ... 1 11 J4073 Rear Natural White Stacked Refractory Brick Liner 1 12 J4506 Bottom Rear Refractory White Brick Liner 1 13 J4508 Bottom Front Refractory White Brick Liner 1 14 J3972 Firebox Support Leg 4 15 Damper Can Collar 1 16 J8013 Kit Screen Assembly 1 17 Firebox Top Assembly 1 18 J3980 Air Kit Door Assembly 1 19 Face Weldment 1 20 J4471 Air Deflector 1 21 Fireplace Top Insulation 1 22 Access Pan...

Страница 18: ...ock F0882 18 8HT 18 Section Hi Temp Double Wall Pipe Snap Lock F0883 24 8HT 24 Section Hi Temp Double Wall Pipe Snap Lock F0884 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Double Wall Pipe Snap Lock 30 OFFSET AND RETURN F0900 30E 8DM 30 Degree Offset and Return F0886 30E 8HT 30 Degree Hi Temp Offset and Return F1908 30E 12DMO 8DMR 30 Elbow Set 12 to 8 Craft...

Страница 19: ...ection F0923 ETLO 8DM Square Top with Mesh and Slip Section MESH SQUARE TOP TERMINATION F0922 ETO 8DM Square Top with Mesh MESH SQUARE TOP TERMINATION WITH SLIP SECTION F0923 ETLO 8DM Square Top with Mesh and Slip Section STAINLESS STEEL HOOD Required when installing a vent free gas log in this fireplace F1053 HS42 42 Stainless Steel Hood w 4 Brow DRAIN PAN F1090 DP42 Drain Pan FIRESTOP THIMBLE F0...

Страница 20: ...Lock F0884 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Double Wall Pipe Snap Lock F0886 30E 8HT 30 Degree Hi Temp Offset and Return F0887 12S 8HT Hi Temp Chimney Support For Use With Chimney Heights In Excess of 30 F0888 RT 8HT Hi Temp Round Top with Mesh Screen F0889 RTT 8HT Hi Temp Round Top with Mesh Screen and Slip Sec tion F0890 RLT 8HT Hi Temp Round T...

Страница 21: ..._____ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _________...

Страница 22: ..._____ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _________...

Страница 23: ...atural or propane gas Fuel products with abnormal burning characteristics including but not limited to fuel such as driftwood coal or plywood and wood products using a binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided ...

Страница 24: ...ecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2015 IHP LLC P N 900574 00 Rev N C 10 2015 P900574 00 WARRANTY KEEP THIS WARRANTY 1508 Elm Hill Pike Suite 108 Nashville TN 37210 Model Number Serial Number Date Installed Dealer s Name Dealer s Phone Number Keep receipt for warranty verification ...

Отзывы: