background image

06

/06

/20

17

 -  Do not store or use gasoline or other flammable 

vapors and liquids in the vicinity of this or any 

other appliance.

 -  WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance. 

•  Do not touch any electrical switch; do not use 

any phone in your building. 

•  Leave the building immediately.

•  Immediately call your gas supplier from a neigh-

bor’s phone.  Follow the gas supplier’s instruc-

tions. 

•  If you cannot reach your gas supplier, call the 

fire department.

 -  Installation and service must be performed by 

a qualified installer, service agency or the gas 

supplier.

       WARNING:
FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly could 

result in serious injury, death, or property damage.

        AVERTISSEMENT:
RISQUED’INDENDIE OU D’EXPLOSION

Le non-respect Des avertissements de sécurité 

pourrait d’entraîner des blessures graves, la mort 

ou des dommages matériels.

 -  Ne pas entreposer ni utilizer d’essence ni d’autres 

vapeurs ou liquides inflammables dans le voisinage 

de cet appareil ou de tout autre appareil.

 -  QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:

• Ne pas tenter d’allumer d’appareil.

• Ne touchez à aucan interrupteur. Ne pas vous servir 

des téléphones se trouvant dans le bâtiment où 

vous trouvez. 

•  Sortez immédiatement de bâtiment.

• Appelez immédiatement votre fournisseur de 

gaz depuis un voisin. Suivez les instructions du 

fournisseur. 

• Si vous ne pouvez rejoindre le fournisseur de gaz, 

appelez le service des incindies.

  -    L’installation et l’entretien doivent être assurés par 

un installateur ou un service d’entretien qualifié 

ou par le fournisseur de gaz.

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future 

reference.

Installateur : Laissez cette notice avec l’appareil.

Consommateur : Conservez cette notice pour 

consultation ultérieure.

This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) 

or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas 

indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit 

is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements 

locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque 

signalétique.  Cet appareil ne peut être converti à d’autres gaz, sauf si une trousse de conversion est utilsée.

Installation and Operation Instructions

Models

PFS

®

US

C

Report No. F14-108

Ce manuel est disponible en francais, simplement  

en faire la demande. Numéro de la pièce 900079-01.

P/N 900079-00   REV. E   06/2017

Sirius™ Direct-Vent Gas Fireplaces

Sirius42TEN

Sirius42TEP

Sirius54TEN

Sirius54TEP

P900079-00

Содержание astria Sirius42TEN

Страница 1: ...sseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L installationetl entretiendoiventêtreassuréspar un installateur ou un service d entretien qualifié ou par le fournisseur de gaz INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference Installateur Laissez ce...

Страница 2: ...E EL VIDRIO CALIENTE CAUSARÁ QUEMADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NIÑOS DEBEN NUNCA TOCAR EL VIDRIO L écran pare étincelles fourni avec ce foyer réduit le risque de brûlure en cas de contact accidentel avec la vitre chaude et doit être installé pour la protection Des enfants et Des personnes à risques Una barrera diseñada para reducir el riesgo de quemaduras desde la mirilla vi...

Страница 3: ... graves si se toca Mantenga a los niños alejados de la chimenea en funcionamiento Supervise en forma cercana a los niños en cualquier cuarto donde haya una chimenea funcionando para impedir el contacto con el vidrio Mantenga la ropa mobiliario gasolina y otros líquidos inflamables alejados de la chimenea Aún después de haber apagado el gas las superficies de la chimenea permanecen extremadamente c...

Страница 4: ... Commonwealth of Massachusetts 11 Cold Climate Insulation 11 Manufactured Home Requirements 12 Location 12 Vent Termination Clearances 13 Minimum Clearances to Combustibles 15 Wall Finishes Surrounds Mantels 16 Installation Preparation 16 Installation Installation Sequence 17 Construct the Fireplace Framing 17 Prepare the Fireplace Top Spacers 19 Route the Gas Supply Line into the Fireplace 19 Ven...

Страница 5: ...ubir des brûlures s ils viennent en contact avec la surface chaude Il est recommandé d installer une barrière physique si des personnes à risques habitent la maison Pour empêcher l accès à un foyer ou à un poêle installez une barrière de sécurité cette mesure empêchera les tout petits les jeunes enfants et toute autre personne à risque d avoir accès à la pièce et aux surfaces chaudes 7 Tout écran ...

Страница 6: ... operating controls is dangerous Improper installation or use of this appliance can cause serious injury or death from fire burns explosion or carbon monoxide poisoning CARBON MONOXIDE POISONING Early signs of carbon monoxide poisoning are similar to the flu with headaches dizziness and or nausea If you have these signs obtain fresh air immediately Turn off the gas supply to the appliance and have...

Страница 7: ...combinations of fuels will degrade the performance of this system and may be dangerous Provide adequate clearances around air openings and adequate accessibility clearance for service and proper operation Never obstruct the front openings of the appliance These appliances are designed as supplemental heaters Therefore it is advisable to have an alternate primary heat source when installed in a dwe...

Страница 8: ...d the warranty Electronic fireplaces are designed with an electronic intermittent pilot ignition system Electrical power 110 Vac line voltage is recommended to operate the fireplace however AA batteries not provided can be used for full time operation or as a backup in case of a power outage Batteries will operate the flame ON OFF function only Electrical power is required to operate the optional ...

Страница 9: ...tured homes The installation must conform to local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 latest edition or the Natural Gas and Propane Installation Code CAN CGA B149 1 The fireplace when installed must be electrically grounded and wired in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70...

Страница 10: ...to bracket with cable Propane tanks are at pressures that will cause damage to valve components Verify that the tanks have step down regulators to reduce the pressure to safe levels Using a propane tank smaller than 100 lbs may create pressure loss and insufficient fuel delivery which can cause sooting severe delayed ignition or other malfunctions see NPFA 58 Any damage as a result of insufficient...

Страница 11: ...lation and repair must be done by a plumber or gas fitter licensed in the Commonwealth of Massachusetts The flexible gas line connector used shall not exceed 36 914 mm in length The individual manual shutoff must be a T handle type valve Massachusetts Horizontal Vent Requirements In the Commonwealth of Massachusetts horizontal terminations installed less than seven 7 ft above the finished grade mu...

Страница 12: ... location the aesthetic and functional use of the fireplace are primary concerns However vent system routing to the exterior and access to the fuel supply are also important The fireplace may be located on or near conventional construction materials See Construct the Fireplace Framing on Page 17 for more information Due to high temperatures the fireplace should be located out of traffic and away f...

Страница 13: ... 1 83 m 16 12 to 18 12 7 0 ft 2 13 m 18 12 to 20 12 7 5 ft 2 29 m 20 12 to 21 12 8 0 ft 2 44 m 12 X Roof pitch is X 12 2 ft minimum 2 ft minimum Lowest discharge opening H H minimum height from roof to lowest discharge opening of vent Horizontal overhang Vertical wall Vent termination Storm collar Concentric vent pipe Flashing 1 26 mm minimum clearance to combustibles Horizontal Vent Termination C...

Страница 14: ...minimum G Clearance to inside corner 2 51 mm minimum 2 51 mm minimum H Clearance to each inside of center line extended above meter regulator assembly 36 910 mm within a height of 15 ft above the meter regulator assembly 36 910 mm within a height of 15 ft above the meter regulator assembly I Clearance to service regulator vent outlet 36 910 mm 36 910 mm J Clearance to nonmechanical air supply inle...

Страница 15: ...d at each side of the unit and any screw heads adjacent to it Hearth Extension A hearth extension is not required with this fireplace Any hearth extension used is for appearance only and does not have to conform to standard hearth extension installation requirements Shelf Height The venting attached to the top vent should be routed in a way to minimize obstructions to the space above the fireplace...

Страница 16: ...a Safe Zone Combustible walls shown in dark gray Combustible mantel legs may project beyond either side of the fireplace opening as long as they are kept within the shaded area illustrated here At 8 1 4 side wall clearance a combustible wall can project 12 5 127 mm At 14 minimum side wall clearance a combustible wall can project to any length 12 305 mm 17 431 mm 14 356 mm 12 305 10 254 8 203 6 152...

Страница 17: ...Operation Page 38 Finishing 15 Install the Glass Media Page 55 16 Install the Baffle Page 39 17 Install the Glass Door and Barrier Page 57 18 Adjust the Air Shutter to Ensure Proper Flame Appearance Page 39 19 Install the Finishing Materials Page 41 20 Attach the Safety in Operation Warning Labels Page 44 1 Construct the Fireplace Framing 1 Frame the fireplace as illustrated in Table 10 or 11 All ...

Страница 18: ...m base of appliance to header d Minimum height from appliance base to vertical centerline of horizontal termination vent pipe with 6 straight vent section and 90 elbow off appliance vent collar NOTE The vertical centerline of the horizontal termination vent pipe is NOT the same as the vertical centerline of the vent frame opening because of firestop spacer offset e Minimum height from appliance ba...

Страница 19: ...ormation on Accessing the Control Compartment NOTE If gas shutoff valve on the fireplace is desired surround kit must be used Refer the gas line routing included in the surround instructions NOTE All codes require a shutoff valve mounted in the supply line Figure 31 Page 38 illustrates the method for connecting the gas supply The flex line method is acceptable in the U S however Canadian requireme...

Страница 20: ...ay not service multiple appliances and must never be connected to a flue serving a separate solid fuel burning appliance NOTE The vent pipe is tested to be run inside an enclosed wall such as a chase There is no requirement for inspection openings in the enclosing wall at any of the joints in the vent pipe 6 Install the Vent Restrictor if necessary 1 Use the vent run descriptions in Figure 11 to d...

Страница 21: ...of and using the vent restrictor install the vent restrictor in the top vent of the fireplace outlet If installing more than 6 ft of vertical venting install the restrictor Figure 12 from inside or outside the unit in the inner fireplace collar The vent restrictor is held in place by friction Vent Restrictor with Horizontal Terminations When horizontally terminating a vent system with a vertical v...

Страница 22: ...ecting vent components Figure 15 Connected vent components Figure 16 Elbow Dimensions Dimple Locking Incline Channel Arrow Appliance Collar or Vent Section Dimple Locking Incline Channel Arrow SV4 5E90 90 Elbow 8 1 8 in 206 mm Swivel Joint 360 swivel 4 13 16 in 122 mm SV4 5E45 45 Elbow Swivel Joint 360 swivel 4 13 16 122 mm 8 1 8 206 mm Swivel Joint 360 Swivel Joint 360 SV4 5E45 45 elbow SV4 5E90 ...

Страница 23: ...0 12 79 5 6 625 0 1 0 2 0 3 492 41 1 0 1 0 10 12 81 6 75 0 0 0 1 1 2 499 5 41 625 0 0 0 1 10 11 91 5 7 625 0 0 2 0 1 3 504 42 1 0 0 1 10 12 93 7 75 0 0 0 0 2 2 511 5 42 625 0 0 0 0 11 11 97 5 8 125 1 0 0 0 2 3 520 5 43 375 0 2 0 1 11 14 103 5 8 625 0 0 0 3 0 3 531 44 25 0 2 2 0 11 15 108 9 1 0 0 3 0 4 538 5 44 875 1 0 0 2 11 14 117 9 75 1 0 5 0 0 6 549 45 75 1 0 2 1 11 15 118 5 9 875 1 1 0 3 0 5 5...

Страница 24: ...eight above the roof and or adjacent walls is specified in ANSI Z223 1 In Canada the current CAN CGA B149 1 installation code by major building codes Always consult your local codes for specific requirements A general guide to follow is the gas vent rule Table 6 The following figures and their associated vertical vent tables illustrate the various configurations that are possible for use with thes...

Страница 25: ...g space above the ceiling level the firestop spacer must be installed on the bottom side of the ceiling If attic space is above the ceiling the firestop spacer must be installed on the top side of the joist Route the vent sections through the framed opening and secure the firestop spacer with 8d nails or other appropriate fasteners at each corner Remember to maintain 1 26 mm clearance to combustib...

Страница 26: ...nt sections through the roof structure Install the roof flashing over the vent section and position such that the vent column rises vertically use carpenters level Nail along perimeter to secure flashing or adjust roofing to overlap the flashing edges at top and sides only and trim where necessary Seal the top and both sides of the flashing with waterproof caulking 11 Install the storm collar Inst...

Страница 27: ...ame rise to run ratios as shown in the venting figures for 90 elbows must be followed if 45 elbows are used NOTE An elbow is acceptable as 1 ft of vertical rise except where an elbow is the only vertical component in the system WARNING Do NOT join separate sections of concentric flexible vent pipe Figure 22 Top Vent Straight Vertical Firestop Spacer u See Clearance to combustibles on Page 24 Secur...

Страница 28: ...op spacer must be used anywhere vent pipe passes through a combustible floor or ceiling Horizontal firestop spacer must be used anywhere vent pipe passes through a combustible wall Install the provided vent restrictor if required A 90 elbow may NOT be attached directly to the appliance collar A minimum 6 pipe section must be used between the fireplace collar and a 90 elbow Total H Max 20 ft 6 096 ...

Страница 29: ...ng or roof joists Allow for elbows Figure 16 Maintain the minimum clearances for combustibles Page 24 2 Frame the exterior wall opening Locate the center of the vent outlet on the exterior wall Table 10 Cut and or frame an opening 10 1 2 x 12 1 8 267 x 308 mm inside dimensions about this center Horizontal firestop spacer must be used anywhere vent pipe passes through a combustible wall 3 Frame the...

Страница 30: ...sts the additional venting components needed in addition to the termination and adaptor for a range of wall thicknesses 11 Attach the termination adaptor Attach the adaptor SV4 5RCH provided with the termination to the vent section or telescoping vent section elbow or fireplace collar Figure 24 NOTE If blown insulation is to be used the through wall shield kit H5816 MUST be installed 12 Install th...

Страница 31: ...the Fire stop Spacer SV4 5HF be installed on the exterior side of the wall Figure 25 Venting Connection and Exterior Wall Recessing of the Horizontal Termination Siding Stucco Max 1 1 4 Recess of Horizontal Termination into Exterior Finishing Material Exterior Surface of Framing 6 to 9 1 4 152 to 235 mm Exterior Surface of Siding Interior Surface of Finished Wall Max 9 1 4 235 mm Wall Thickness Ty...

Страница 32: ...r must be used any time vent pipe passes through a combustible floor or ceiling SV4 5HF Secure Vent SF4 5HF Secure Flex firestop spacer must be used any time vent pipe passes through a combustible wall WARNING Do not join separate sections of concentric flexible vent together Table 22 Top Vent One 90 Elbow Maximum total H Minimum total V feet meters feet meters 2 0 610 1 0 305 4 5 1 372 3 0 914 6 ...

Страница 33: ...ection must be used between the fireplace collar and a 90 elbow V H H1 Horizontal Termination Vertical Firestop Spacer u Horizontal Firestop Spacer u Table 24 Top Vent Three 90 Elbows Maximum total H Minimum total V feet meters feet meters 2 0 610 1 0 305 4 5 1 372 3 0 914 6 1 829 4 1 220 7 5 2 286 5 1 524 9 2 743 6 1 729 15 4 572 10 3 048 Total H 15 ft 4 572 m maximum Total H Total V 60 ft 18 3 m...

Страница 34: ...etails 1 3 4 44 mm flexible vent and adaptor outer collar overlap Adaptor SV4 5RF Attach adaptor to vent collar or Secure Vent sections 1 3 4 44 mm flexible vent and adaptor inner collar overlap Gear clamps Flexible vent Flexible vent section 5 127 mm radius minimum Shown here 36 Flex Connector Kit H7748 36 of flex with two adaptors for mating two rigid sections of vent together 1 Install the Inne...

Страница 35: ...termination and adaptor collars are a different circumference than Secure Vent collars Secure Flex vent has a longer center tube to improve ease of installation 8 Complete the Field Wiring CAUTION The ground supply lead must be connected to the wire attached to the green ground screw located on the outlet box see wiring diagrams Failure to do so will result in a potential safety hazard The applian...

Страница 36: ...SSEMBLY B BLACK BR BROWN GY GRAY PU PURPLE R RED BL BLUE G GREEN O ORANGE W WHITE Y YELLOW WIRING COLOR CODE B B B R R W W B B B B BL BL G G O Y Y R R Y W G G O SCHEMATIC REPRESENTATION ONLY 2 Remove the electrical inlet cover plate from the side of the unit by removing the plate securing screws 3 Remove the cover plate knockout then feed the power supply wire through the knockout opening and into...

Страница 37: ... 57 3 The battery holder is attached via cable to the CPI IPI bracket on the left hand side Figure 50 Pull the cable until the battery holder is visible Turn the battery holder such that it will clear the unit and can be removed from the unit the black and red wires will still be connected to the unit 4 Place the four 4 provided AA batteries into the holder Align the end of the batteries the the s...

Страница 38: ...prevent moisture and debris in the gas line from damaging the valve Test Factory and Field Connections for Gas Leaks WARNING Never use an open flame to check for leaks Turn on gas supply and test for gas leaks using a gas leak test solution also known as bubble leak solution NOTE Using a soapy water solution is an effective leak test solution but it is not recommended because the soap residue that...

Страница 39: ... Any damage due to sooting resulting from improperly setting the air shutter is not covered under the warranty The air shutter door and nearby appliance surfaces are hot Exercise caution to avoid injury while adjusting flame appearance Flame Appearance and Sooting The flame should be blue at the base and yellow orange in the body of the flame When the fireplace is first lit the entire flame may be...

Страница 40: ...ment Amount of Primary Air Flame Color Air Shutter Adjustment If air shutter is closed too far Flame will be orange Air shutter gap should be increased PULL lever toward front of fireplace If air shutter is open too far Flame will be blue Air shutter gap should be decreased PUSH lever toward back of fireplace Air shutter adjustment lever below glass door 1 Move the adjustment lever Figure 34 down ...

Страница 41: ...oncombustible board over the supplied noncombustible board The fireboard supplied with the unit is not intended to be the finish material 2 Install non combustible fiberboard at top of fireplace NOTE If skimming the non combustible fiberboard to match drywall use Sheetrock brand Durabond 90 setting type joint compound to fill all joints These trademarks are owned by United States Gypsum Company or...

Страница 42: ...any 5 Cut noncombustible fireboard to size and install flush with top of frame pieces 6 Finish out wall with 1 2 finishing materials paint with high temperature paint etc A total of 1 finish material is needed to be flush with the surround back 7 Attach surround in frame using screws a minimum of six at specified locations Figure 41 8 Install barrier mounting brackets on side of surround Insulatio...

Страница 43: ...on barrier mounting brackets Figure 40 Gas Shutoff Valve Bracket Figure 41 Installing the Surround Back Side Gap thread flex gas line here Tab bend up to hold valve Figure 42 Noncombustible Material with Bezel and Barrier Surround mounting brackets Clean Face Frame removed first Bezel and Barrier added after Surround not shown One 1 Top non combustible board Barrier added after surround Gas Shutof...

Страница 44: ...ed in the kit 1 Insert the 3 volt battery into the battery bay in the remote control Figure 43 Correctly align polarity 2 Insert the 4 provided AA batteries into the receiver battery bay Figure 43 Correctly align polarity Figure 43 Remote and Wall Receiver Battery Compartments Figure 44 Remote Control Transmitter 20 Attach the Safety in Operation Warning Labels 1 Attach the furnished safety instru...

Страница 45: ... sur la surface de la plaque de l interrupteur mural qui contrôle le foyer Figure A ou du thermostat mural Figure B Choisissez la langue qui est principalement parlée dans la résidence du propriétaire En cas de doute collez l étiquette en anglais 2 Si une télécommande est utilisée pour contrôler le foyer nettoyez la soigneusement pour éliminer la poussière et les traces de graisse ou d huile Colle...

Страница 46: ...L75 SV4 5LA Telescopic Length Slip Section 2 7 1 2 rigid 77L76 SV4 5E45 45 Elbow 77L77 SV4 5E90 90 Elbow Catalog Number Model Description The following flashing comes packaged with a storm collar 77L78 SV4 5F Flat Roof Flashing 77L79 SV4 5FA 1 12 to 7 12 Adjustable Flashing 77L80 SV4 5FB 7 12 to 12 12 Adjustable Flashing 77L81 SV4 5SC6 Storm Collar 6 pack H6183 SV4 5HF5 Firestop Spacer 5 rigid H61...

Страница 47: ... 36 914 mm compressed flex 77L91 SFKIT48S Square Term for flex with 48 1219 mm compressed flex 91L66 SFGC4 6 Gear Clamp 4 5 114 mm for flex 6 pack 91L67 SFGC7 6 Gear Clamp 7 5 190 5 mm for flex 6 pack F3191 SV4 5AdaptorKit Secure Flex Adaptor Kit Includes rigid to flex adaptor and flex to rigid adaptor flex not included Catalog Number Model Description 94L04 SFKIT12SS Small Square Termination for ...

Страница 48: ...s dommages matériels des blessures ou la mort Le tecnicien agréé est responsable de l installation de cette trousse L installation n est pas adéquate ni complète tant que le bon fonctionnement de l appareil converti n a pas été vérifié selon les instructions du fabricant fournies avec la trousse Le fournisseur de service qualifié ayant réalisé l installation assume les responsabilités liées à la c...

Страница 49: ...re 45 7 Remove the control compartment access door and gasket Figure 49 Figure 45 Removing the Burner and Accessing the Control Compartment Figure 46 Removing the Air Shutter Adjustment Rod Control Compartment Access Panel and Gasket Right Burner Bracket Remove two screws to remove burner assembly Burner Assembly Right Burner Bracket Venturi Burner Orifice Air Shutter Adjustment Rod 8 Refer to the...

Страница 50: ...nsure the air shutter clears the pilot bracket 18 Turn ON the gas supply to the fireplace and relight the appliance Page 64 With the main burner ON use a gas leak test solution to test the new pressure regulator assembly and all gas line joints for leaks Page 38 19 Attach the conversion information label to the rating plate 20 Locate the valve test ports Figure 1 Using a manometer test the inlet a...

Страница 51: ...fluence of alcohol and those at high altitudes NOTE Do not place furniture or other combustible materials within 36 of the front of viewing area s NOTE Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition Remarqué Les enfants et les adultes devraient être infor més des dangers que posent les températures de surfac...

Страница 52: ... chimenea encendiéndola y apagándola Limpiebienlaplacadelinterruptoroeltermostatode paredparaquitarelpolvoyaceite Peguelaetiqueta enlasuperficiedelaplacadelinterruptorquecontrola la chimenea Figura A o en el termostato de pared Figura B Seleccione el idioma que más se habla en la casa 2 Si se usa un control remoto para controlar la chimenea encuentre el transmisor y límpielo bien para quitar el po...

Страница 53: ... not flowing to the pilot and burner the service shutoff valve located in the fireplace control compartment may need to be opened Contact your dealer or distributor for more information To access the service shutoff valve remove the glass door burner floor panels and control compartment access panel in the fireplace floor In units with the surround installed the gas shut off valve is locate below ...

Страница 54: ...e the remote control transmitter where children cannot reach it Wall Switch Receiver Low Battery Power Detection Battery life depends on several factors including battery quality and number of fireplace ignitions When the batteries are low or depleted the fireplace can only be operated manually ON OFF When the depleted batteries are replaced the receiver will resume normal operation Remote Control...

Страница 55: ...gas line has been connected and tested for leaks and initial burner operation has been confirmed Install the side panels 1 Align screw hole in top flange of side panel with upper hole in inside wall of fireplace 2 Align screw holes in bottom flanges of side panel with holes in front ledge and rear ledge 3 Secure each panel with three 3 screws Install back panel 1 Insert bottom edge of back panel i...

Страница 56: ...gure 51 Do NOT mound the media Figure 51 Installing the glass media Do NOT place media on burner or around pilot Glass media area NOTE It is important to ensure proper media placement per the manual when installing these units Verify pilot flame is not obstructed Ensure media does not fall through the pilot hole in the floor See Verifying Appliance Operation on Page 38 ...

Страница 57: ...anufacturer Do not attempt to replace broken cracked or chipped glass separately Do not attempt to touch the front enclosure glass with your hands while the fireplace is in use WARNING Do not operate appliance with the glass front removed cracked or broken AVERTISSEMENT Ne pas utiliser l appareil si le panneau frontal en verre n est pas en place est craqué ou brisé WARNING Any safety screen guard ...

Страница 58: ...Proper door alignment and sealing are important to the operation and performance of the fireplace Ensure the door seal is contacting the frame and that no air leaks are present 3 Align the screw holes below the glass door with the holes in the fireplace and secure using the three 3 provided screws Figure 52 4 For cleanface installations install the modesty panel 5 Install barrier Removing the glas...

Страница 59: ... system components However more frequent periodic inspections and cleanings should be performed by the homeowner NOTE Prior to the first use of the fireplace and each burn season and periodically during the burn season inspect the horizontal termination for debris such as bird nests leaves paper or branches Remove any items from the surfaces of the termination prior to use Also be aware of shrubs ...

Страница 60: ...g the glass media Carefully follow the placement instructions Page 55 This will ensure a proper flame and safe combustion NOTE Improper positioning of media can create carbon build up and will alter the performance of the fireplace Replacing the media If the media needs replacement use only the proper replacement media from manufacturer Page 62 Cleaning the burner Carefully remove the media Vacuum...

Страница 61: ...fle inspect the vent system at the top and at the base within the firebox for signs of blockage or obstruction Look for any signs of dislocation of the vent components Fireplace Inspection Qualified Service Technician Perform the appropriate fireplace inspection procedure detailed in this manual Page 38 Replacing Batteries Homeowner Qualified Services Technician For electronic gas valve models Rep...

Страница 62: ...SCTPSAB Black touch up paint powder coat exterior Catalog Model Description H5820 4 5HTSK Termination Shroud 87L02 SV4 5HGS Termination Guard Deluxe 17M52 SV4 5HGS 1 Termination Guard Square Square Termination Guard fits 94L10 and H1968 Deluxe Termination Guard fits 94L10 and H1968 Termination Shroud fits H1968 Catalog Model Description H8412 CRSHGL RBLK Bag of Glass Media Reflective Black H8424 C...

Страница 63: ...TAT Cost Effective Solution Catalog Number Manual ON OFF operation Works with millivolt and low voltage electronic ignition controls Kit includes remote and receiver F2236 Model RCKit4001 RC S 1 Manual or up to 3 hour timer modes Catalog Number LCD display Shows room temperature in F and C Wall clip included Receiver wall mounted or placed in the control compartment White face plate included Flame...

Страница 64: ...ater Electronic Gas Control Valve SIT Electronic Pilot Assembly 3 Turn off all electric power to the appliance if service is to be performed Note The control may have a battery backup remove batteries if installed 4 Close the main line gas shut off valve 1 STOP Read the safety information above on this label 2 Read the Care and Operation manual including the section on Remote Control System if app...

Страница 65: ...oir une batterie de secours installer les batteries au besoin 8 Placez l interrupteur du récepteur en position REMOTE ou l interrupteur mural en position ON 9 Si applicable Appuyez sur le bouton ON OFF pour sélectionner ON 10 Si applicable Ajustez le thermostat sur la télécommande à l ajustement désiré 11 Si l appareil ne se met pas en marche suivez les instructions intitulées Comment couper l adm...

Страница 66: ...f air call a service technician if required e Unit is not receiving power Replace unit battery backup 3 The main Burner comes on but then goes out a Fireplace has not established proper draft Switch CPI IPI switch to pilot ON mode wait two 2 minutes then relight b Gas is not reaching the fireplace Check the gas supply and gas shutoff valves c Loose wires to the valve or ignition module Check contr...

Страница 67: ...9189 1 Wall Switch Receiver Kit H8564 1 H8564 1 3 DFC Wire Harness H8601 1 H8601 1 4 Ground Wire H7278 1 H7278 1 5 DFC Ignition Board J7906 1 J7906 1 6 Natural Gas Valve H8562 1 H8562 1 7 Propane Gas Valve H8594 1 H8594 1 8 Natural Gas Pilot Assembly H7268 1 H7268 1 9 Propane Pilot Assembly H7269 1 H7269 1 10 Glass Door Latch H8433 1 H8433 1 Flex Gas Connector Assembly 93L32 1 93L32 1 Orifice Conn...

Страница 68: ...Aux Out 3 9 7 11 12 13 Replacement Parts Homeowner Replacement Parts Description 42 54 Catalog Number Qty Catalog Number Qty Remote Control Transmitter Kit RCKIT4001 F2236 1 F2236 1 11 Glass Door H8799 1 H8431 1 12 Top Baffle H8787 1 H8583 1 13 Blower Assembly FBK 250 optional 80L86 1 80L86 1 14 Barrier J7427 1 J7426 1 WARNING Never use substitute materials Use of non approved parts can result in ...

Страница 69: ... fire flood or acts of God b damages caused by abuse negligence misuse or unauthorized alteration or repair of the Product affecting its stability or performance The Product must be subjected to normal use The Product is designed to burn either natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive te...

Страница 70: ...er Date fireplace was Installed Type of gas fireplace uses Dealer name Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information Printed in U S A 2014 Innovative Hearth Products P N 900079 00 Rev E 06 2017 1508 Elm...