3
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Pivot Pin
Roller Pin
Upper Door
Guide Track
Spring Clip
Fully Open or
Fully Closed
Front-Open Systems
ADJUSTMENT fOR DOOR ALIGNMENT
The doors are properly adjusted when the top door trim is in a straight,
level line and the gap between the doors is even at the top and bottom.
If adjustments are required, grasp the door handle and loosen the lower
door pivot pin using a 3/8" open end wrench*. Slide the door panel on
the hinge pin until the gap between the upper door trim and upper frame
is even. Retighten the lower door pivot pin*. Repeat this procedure for
the opposite door if needed.
*NOTE: Upper door pivot pins can also be loosened for adjustment
purposes; however, it is easier to loosen lower pins.
GENERAL OPERATING PRECAUTIONS AND INSTRUCTIONS
CAUTION: ThESE GLASS DOORS ARE LISTED ONLY fOR USE WITh ThE
fIREPLACE OR APPLIANCE MODELS ShOWN ON ThE fRONT PAGE.
USE ON ANY OThER fIREPLACE OR APPLIANCE MAY CONSTITUTE A
POTENTIAL fIRE hAZARD.
• Use fireplace tools carefully to avoid striking the glass.
• Keep wire mesh screens closed during fireplace use.
Lower
Pivot Pin
Figure 6
Figure 8
Figure 7
Step 2. Tilt the top of the door into place and carefully ensure that the
upper pivot pin and roller pin is in the upper door guide track.
Step 3. Continue to tilt the top of the door into place until the upper pivot
pin engages the spring clip and the pivot pin locks into place
within the hole of the spring clip
(see Figure 7)
.
Step 4. Repeat this procedure for the opposite door assembly.
IMPORTANT: ThE fINISh Of ThESE DOORS MAY BE PROTECTED WITh
A SELf ADhERING PLASTIC COATING ThAT MUST BE REMOVED BEfORE
hEAT IS GENERATED BY A fIRE IN ThE fIREBOX. TO PREVENT MELT-
ING, ENSURE ThAT ANY PLASTIC COATING PROTECTING ThE fINISh
Of ThESE DOORS IS REMOVED fOLLOWING INSTALLATION. REfER TO
ThE fIREPLACE INSTALLATION AND CARE AND OPERATION INSTRUC-
TIONS fOR DETAILED INSTRUCTIONS REGARDING ThE MAINTENANCE
Of ThE fINISh Of ThESE DOORS.
CAUTION: ThE fRONT-OPEN fIREPLACE OR APPLIANCE ShOULD
ONLY BE OPERATED WITh ThE GLASS DOORS fULLY OPEN OR fULLY
CLOSED
(SEE FIGURE 8)
.
CAUTION: GLASS AND METAL fRAMES GET hOT — ALWAYS USE
hANDLES TO OPEN AND CLOSE ThE DOORS.
CLEANING
NEVER CLEAN ThE GLASS WhEN ThE DOORS ARE hOT. DO NOT USE
AMMONIA OR ANY AMMONIA BASED GLASS OR hOUSEhOLD CLEANER
TO CLEAN ThE GLASS OR ThE DOOR fRAME. AN AMMONIA BASED
CLEANER WILL DAMAGE ThE fINISh.
Remove dirt and grime from the doors using a clean dampened towel
followed by wiping with a dry towel. To remove stubborn stains from the
doors, use a mild soap solution and towel to gently scrub away stain.
Take care not to scratch the glass surface. Do not use abrasive cleaners.
IMPORTANT: ThESE GLASS DOORS UTILIZE TEMPERED GLASS WhICh
IS DESIGNED fOR USE WITh hIGh TEMPERATURES BUT CAN UNEX-
PECTEDLY ShATTER. DO NOT SIT CLOSE TO ThE GLASS.
Tempered glass will break into small particles if it should shatter unex-
pectedly. If the glass breaks, particles of extremely hot glass could be
discharged into the surrounding environment, thereby creating a risk of
personal injury or fire. Observation of the above operating precautions
and instructions will reduce the risk of personal injury or fire.
If the tempered glass pane becomes scratched or chipped, it creates a
weakness in the glass which can cause the glass to break when heated.
Replace the pane of glass by contacting your nearest distributor or dealer.
f i r e - p a r t s . c o m