Safety Instructions, Protective Measures and Guidelines 

D8-3_EN 

– V1.0 

4/14 

1.4 

Safety Instructions 

1.4.1 

Classification of Information 

The degree and type of hazard are assigned to one of the following classes. 

 

DANGER! 

Safety instructions marked with 

DANGER

 indicate an imminently hazardous situation. 

A disregard of the notice 

inevitably

 leads to a 

serious or even fatal accident

 

 

WARNING! 

Safety instructions marked with 

WARNING

 indicate a potential hazardous situation. 

Failure to observe this notice is 

likely

 to result in a 

serious or fatal accident

 or 

property damage

 

 

CAUTION! 

Safety instructions marked with 

CAUTION

 indicate potential danger. 

Failure to comply with the notice may 

possibly

 result in an 

accident

 or 

property damage

 

 

NOTE 

Safety instructions marked with 

NOTE

 indicate a potential hazardous situation. 

Disregard of the notice may 

possibly

 result in 

property damage

1.5 

Electromagnetic Compatibility 

 

WARNING! 

 

Risk of injury due to interference with signals and devices 

Disturbed signals can cause unforeseen device reactions. Carry out the wiring in accordance with the EMC measures. 
Failure to follow these instructions can result in death, serious injury, or material damage 

 

 

Measures for EMC 

Effect 

Device assembly 

Use cable clamps for the shield support, 
connect metal parts over a large area. 

Good conductivity due to surface contact. 

Switching devices such as contactors, relays 
or solenoid valves with interference 
suppression units or spark suppressors (e.g. 
diodes, varistors, RC elements) 

Reduce mutual interference couplings. 

Wiring 

Keep cables as short as possible. 

Avoid capacitive and inductive interference. 

 

 

Содержание motion Plastics D8-3

Страница 1: ...V1 0 1 14 igus motion Plastics dryve D8 3 Stepper Motor Control System Step Direction Loop Mode 1 60 rpm Manual V 1 0 Website MotorShop http www igus eu motorshop Videos Tutorials www igus eu dryve t...

Страница 2: ...2 1 4 Environmental conditions 6 3 Installation 7 3 1 Mechanical Installation 7 3 2 Electrical Installation 7 3 2 1 Pin Assignment 8 3 2 2 Connection Scheme Signal In Output 8 3 3 Integration into Saf...

Страница 3: ...sonal injury or damage to property resulting from misuse or unauthorised technical modification of the motor controller igus reserves the right to make changes and improvements to the product or the t...

Страница 4: ...nt or property damage NOTE Safety instructions marked with NOTE indicate a potential hazardous situation Disregard of the notice may possibly result in property damage 1 5 Electromagnetic Compatibilit...

Страница 5: ...dditional switches and sensors Simple control With the loop mode a continuous movement between 2 limit switches can be executed without the need for a master controller The movement is executed at a f...

Страница 6: ...n 50 s Dissipation Loss Max 264 W Digital Inputs Outputs Galvanically Separated by Optocoupler Voltage supply output Out Max 30 V Current output Out Max 100 mA Boot up time 2 s Cable length Max 30 m L...

Страница 7: ...stallation The motor controller is constructed for use with direct currents Every voltage mentioned in this manual can be regarded as direct current WARNING Risk of injury Make sure that an emergency...

Страница 8: ...t Negative limit 5 V to 24 V 4 DIR Direction input Negative limit ground 0 V 5 EN Enable Movement Start signal 5 V to 24 V 6 EN Enable Movement Start signal ground 0 V 7 Out Power supply status output...

Страница 9: ...urrent No voltage free status of the motor Switching off the enable signal EN Direct de energisation of the motor Uncontrolled coasting of the motor Motor could remain energised in a fault condition S...

Страница 10: ...are available for configuring the motor control These can be used to preselect the emitted motor current during a movement the step mode the emitted current at standstill and the fixed motor speed in...

Страница 11: ...1 3 Micro Stepping If the motor controller is used in Pulse Mode p 13 the desired micro step mode must be preselected by the combination of switch SW4 to SW6 and SW 8 By preselecting the micro steps p...

Страница 12: ...FF OFF OFF OFF 4 1 5 Drive Mode The desired operating mode is set via switch SW8 Drive Mode SW8 Pulse Mode Step Direction ON Loop Mode Constant Speed OFF 4 2 Motor Direction For a proper operation it...

Страница 13: ...e connected to the STEP input and the negative to DIR To start the continuous motion sequence a 5 V to 24 V signal must be applied to input EN After applying the signal a movement towards the positive...

Страница 14: ...SET 1 Top Hat rail mounting clip with matching screw Connectors D8 CONNECTOR SET Complete set off all dryve D8 1 connector plugs 8 Service Customer service de dryve igus net 49 0 2203 9649 845 Technic...

Отзывы: