IGT W46 Скачать руководство пользователя страница 2

IGT Testing Systems, P.O.Box 12688, 1100 AR Amsterdam, The Netherlands 

Keienbergweg 25, 1101 EX Amsterdam, The Netherlands 

Phone +31 (0)20 409 9300, Fax +31 (0)20 697 4842, E-mail: 

[email protected]

  Internet: www.igt.nl

 

W46 for IGT AIC2-5T2000

 

 
17.

 

Examine or measure the results as pointed out in the chapter 
“Assessment”. 

18.

 

If desired, repeat the points 1 thru 17 for other interval 
times. 

19.

 

Repeat the points 1 thru 18 for the other types of paper or 
ink. 

20.

 

After having finished the tests, clean and store all parts as 
described in the manuals. 

21.

 

Make an 
accurate 
record of 
the 
conditions 
and the 
results of 
the test. 

 
Assessment 
See figure 2. 
 
1.

 

Visually 

 

Judge the 
differences 
between the 
prints for 
different 
interval 
times of 
both colour 
sequences. 

 

The colour 
sequence 
with the smallest difference between the prints of different 
interval times is the best colour sequence. 

 
2.

 

Densitometrically 

2.1.

 

After > 4 hours after making the print measure the contrast 
density of all parts (both single colours and both colours) of 
the strips with 
the 
densitometer 
set for the 2

nd

 colour. 

2.2.

 

Calculate the average of the measured densities per part. 

2.3.

 

Calculate the % of ink transfer with the formula: 
 

                              D

(1+2)

 – D

1

 

                    F = ------------------ x 100 % 
                                    D

2

 

In which: D

(1+2)

   = density of both colours together 

D

= density of 1

st

 colour,   D

2

 = density of 2

nd

 colour 

2.4.

 

The highest % of ink transfer is the best colour sequence. 

 

Notes

1.

 

The test results of the AIC205T2000, AIC2-5 and Global 
Standard Testers 2 compare well with another on the 
condition that the tests have been carried out under the same 
testing conditions. 

 
2.

 

It is advised to use the following settings for the High Speed 
Inking Unit 4: 

 

Water bath 

 

: 23.0º C (73.4º F) 

 

Mode  

 

: 2 

 

Starting time   

: 5 s 

 

Distribution time 

: 10 s 

 

Distribution speed 

: 1.2 m/s 

 

Inking time printing discs : 5 s 

 
3.

 

To reach an ink film thickness of 2.4 µm on the High Speed 
Inking Unit 4 with a 4-segmented toproller a quantity of 
0.10 cm³ has to be applied. It is not advised to add some ink 
after a test. 

 
4.

 

In most of the cases the extra interval times of 3 and/or 6 s 
will be used. The time of 0.1 s will present as a result of the 
speed 1.0 m/s. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

This information leaflet has been compiled with the utmost care. 
However, may you find any inadequacies or if there are any comments, 
we kindly request you to send these to IGT Testing Systems, Sales 
Department. 

Fig. 2 Wet-on-wet printing  

                                  Beginning of print 
 
 
2

nd

 colour 

 

 

 

 
 

 

 

1

st

 and 2

nd

 colour 

with interval time 
0.07 s for 1 m/s 
 

 

A + B 

0.07 s 

 

B + A 

0.07 s 

 
1

st

 and 2

nd

 colour 

with interval time 
i s 
 

 
 

A + B 

i s 

 

 

B + A 

i s 

 
 
1

st

 colour 

 

 

 

 
 

 

 

 

 

Отзывы: