Solving Ticket SSR Error
After powering on the machine, if the hopper keeps working and can’t be stopped,
it could be that the Ticket SSR’s jump setting is incorrect.
How to solve:
1. Locate the Ticket SSR jump (JP12) on the PC board. Then identify current
TICKET SSR is at HIGH ACTIVE or LOW ACTIVE.
2. Change to use the alternative JP12 setting.
Low Active
3 2 1
Short pins 1-2
JP12
High Active (Default)
3 2 1
Short pins 2-3
Содержание Mega Play