background image

–  4  –

Quick Start Guide

The ceiling mounting plate supports two different kinds of ceiling bars. The 
position illustrated above is for 15 mm bars. Use the other position at a 90 degrees 
angle for 24.5 mm bars.

3. Connect Cables

Connect Ethernet cable to the 1000BASE-T (PoE) port on the unit.

4. Connect Power

The AP can be powered either by the power supply provided in the box or by an 
optional 802.3af/at PoE switch.

Powering the AP with a power supply

 

Connect Category 5e or better cable to the 
leftmost RJ-45 port.
This 1000BASE-T (PoE) port is named 

ETH0

.

Connect the other end of this cable to a 
LAN switch.

(Optional) Connect local LAN devices to 
any of the other RJ-45 ports of the 
connector panel using Category 5 or better 
cable.
These 100BASE-T ports are named 

ETH1

 

and 

ETH2

.

1

2

1

2

 

Connect the cable from the power supply to 
the DC connector of the AP.

Connect the power supply to a nearby AC 
power source (100-240 VAC, 50/60 Hz).

1

1

Содержание SunSpot N300

Страница 1: ...nting plate for attaching the AP to the ceiling The access point can be powered either by the universal power supply included in the box or through an Ethernet cable connection from an optional PoE sw...

Страница 2: ...e in local radio regulations prior to equipment installation 1 Unpack the AP Unpack the AP and check the package contents Outdoor Stand Alone Access Point SunSpot AC1200 or SunSpot N300 Ceiling mounti...

Страница 3: ...he mounting holes on the back of the AP Use the screw plugs and screws provided in the box of the AP or verify that the size of the head of the screws is small enough to fit through the mounting holes...

Страница 4: ...the box or by an optional 802 3af at PoE switch Powering the AP with a power supply Connect Category 5e or better cable to the leftmost RJ 45 port This 1000BASE T PoE port is named ETH0 Connect the ot...

Страница 5: ...that this switch is connected to the LAN Note Connecting the Ethernet cable from the AP to the injector module powers on the unit 5 Verify AP Operation Verify basic AP operation by checking the system...

Страница 6: ...45 port The AP has a default management IP address of 192 168 2 1 and a subnet mask of 255 255 255 0 You must set your PC IP address to be on the same subnet as the AP that is the PC and AP addresses...

Страница 7: ...TX 2 4 GHz Radio IEEE 802 11b g n 5 GHz Radio IEEE 802 11a n ac Radio Frequencies 2412 2472 MHz 5745 5825 MHz China 5180 5320 MHz ETSI 5500 5700 MHz ETSI Power Supply Power Supply 100 240 VAC 50 60 H...

Отзывы: