Quick Start Guide
– 2 –
Power Up
Standard Bracket Alignment
IgniteNet strongly recommends using the ICC-SCOPE-9x50
Alignment Scope for alignment. To install, place the scope on top of
the MetroLinq™ housing and secure it with its thumb screw.
Connect an Ethernet cable from the MetroLinq™ ETH PoE IN
port to the PoE port on the power supply.
Connect Ethernet cable from the “LAN” port on the power
supply to your LAN device.
Connect the power cord to a nearby AC power source.
1
2
3
Note:
Do not adjust bolts A and B without first loosening 1
and 4 respectively.
Loosen coarse adjustment bolts 2 and 3 and set initial
alignment. Don’t worry, you don’t have to be too accurate
yet. After you have set the coarse alignment, tighten bolts 2
and 3.
Loosen the horizontal fine-tune adjustment bolt 4. Use fine-
tune bolt "B" to optimize the horizontal position. Re-tighten
bolt 4.
Loosen the vertical fine-tune adjustment bolt 1. Use fine-
tune bolt "A" to optimize the vertical position. Re-tighten
bolt 1.
Initial alignment should be based on optical or visual
alignment. After you achieve this, repeat steps 2 and 3 while
watching the 60 GHz signal strength LED. Optimize position
to the LED indicator.
Ensure all bolts are fully tightened, remove the alignment
scope (if installed), and enjoy Gigabit interference-free
wireless.
2
1
4
A
2
3
B
1
2
3
4
5