Quick Start Guide
– 2 –
Grounding
Power Up
Standard Bracket Alignment
IgniteNet strongly recommends using the ICC-SCOPE-9x50
Alignment Scope for alignment. To install, place the scope on top of
the MetroLinq™ housing and secure it with its thumb screw.
Ensure the structure on which the unit is to be mounted is
properly grounded and in compliance with local and
national electrical codes.
Verify that there is a good electrical connection to a
grounding point (no paint or isolating surface treatment).
Use the included (M4) screw to attach a grounding wire (not
included) to the grounding point on the unit, and then to
ground.
Caution:
The earth connection must not be removed
unless all supply connections have been disconnected.
Connect an Ethernet cable from the MetroLinq™ ETH PoE IN
port to the PoE port on the power supply.
1
2
1
Connect Ethernet cable from the “LAN” port on the power
supply to your LAN device.
Connect the power cord to a nearby AC power source.
Note:
Do not adjust bolts A and B without first loosening 1
and 4 respectively.
2
3
1
4
A
2
3
B