Heated Display Cases

 

 

 

When cleaning inside the unit, do not leave the front glass lifted in the aluminum 
profile. This may cause the damage to the glass and is not covered by the 

warranty. Please remove the glass during cleaning. (Figure 5)  

 

Elements of equipment can corrode as result of improper use and maintenance. To 
prevent damage:

 Do not allow contact of the with substances containing chlorine and/ 

or baking soda in different varieties, which destroy the protective layer and components 
of the equipment (also includes various stainless steel) 

 

 

 

 

 

 

 

 

6. SERVICE 

6.1. Faults identification and repair 

In the case of any difficulties during actuation of the equipment or during its operation, please return to the 
chapters in this manual, which explain the performed operation. This aims to ensure the equipment is properly 
operated. If you still experience difficulties, the following might help you solve the problem. 
 

The equipment is not working... – Make sure that: 

•   Voltage and frequency are compliant with those recommended by the manufacturer. 
•   The unit is connected to the supply network. 
•   The main switch on the control panel is turned on. 
 

The equipment is operating, but the light is off... – Make sure that: 

•    Light switch is turned on. 
•    Lamp, starting switch, or power supply of the unit is not burnt. 
 

The equipment does not reach the proper temperature, the light is on... – Make sure that: 

•    The main switch is on. 
•    Heating temperature is properly set. 
•    The heater is not burnt. 

Steam precipitation on the glass of the device is a normal phenomenon in case of 
high relative air humidity exceeding 60% and does not require calling for service! 

1 – Front glass 
2 – Upper aluminum profile (lift guide) 
3 –Lower aluminum profile (catch) 

Figure 5 Front glass disassembly 

 

Содержание HDCD2

Страница 1: ...Countertop Heated Display Cases Models HDCD Instruction Manual Tel 416 663 3051 Fax 416 663 5793 Toll Free 1 888 408 8819 124 Norfinch Dr Toronto ON M3N 1X1 REFRIGERATION LTD...

Страница 2: ...irements 5 3 2 Unit location 5 3 3 Connection and start up 5 4 UNIT START UP 6 4 1 Temperature regulation 7 4 2 Moistening system 7 5 MAINTENANCE 7 5 1 Cleaning and maintenance 7 6 SERVICE 8 6 1 Fault...

Страница 3: ...eated display case with forced hot air circulation and moistening system Special water container placed inside the unit regulates the air humidity inside the display case Electric heater is the heatin...

Страница 4: ...ontainer pulled out 9 Top 10 Polycarbonate screens 11 Leveling legs 12 Control panel Figure 2 Layout of containers 2 3 Technical data Table 1 Technical data Model Voltage V Hz Ph Rated Current A Usabl...

Страница 5: ...the efficiency of the unit 3 3 Connection and start up Remove the protection foil from the elements of the unit e g from the inside of the unit and working top The first cleaning of the equipment shou...

Страница 6: ...products placed in the unit and temperature of the surroundings The equipment should be placed in a dry and well ventilated place Remarks and indications Before placing hot products in the display ca...

Страница 7: ...of HDCD display case it is impossible to accurately regulate humidity moistening occurs when hot air lifts water particles from the special container Filling the container emptying the container may...

Страница 8: ...lain the performed operation This aims to ensure the equipment is properly operated If you still experience difficulties the following might help you solve the problem The equipment is not working Mak...

Страница 9: ...rigeration service Telephone number 416 663 3051 or toll free 1 888 408 8819 E mail service igloo400 com If after checking points described in chapter 6 1 Faults identification and repair and the unit...

Отзывы: