REFRIGERATION LTD
Pastry Display Cases
| www.igloorefrigeration.com
13
• The main switch is turned on.
• Thermostat is turned on.
The equipment is operating, but the light is off... – Make sure that:
• Light switch is turned on.
• Lamp or starting switch of the equipment are not burnt.
Water leakage from under the device
• Check whether the equipment is properly levelled.
• Empty the condensate container.
The equipment does not reach the proper temperature, the light is on... – Make sure that:
• The main switch is on.
• Temperature setting on the thermostat is properly set.
• Thermostat works properly.
• The condenser is clean, if necessary – clean the condenser.
• Ambient temperature does not exceed 25ºC.
• Enough time has passed for products to be cooled.
• Ventilation holes are not blocked.
• Relative air humidity no more than 60%.
Thermostat displays E0 or E1 or L0 or HI or EE or Ed or DF instead of temperature:
• E0 – failure of temperature sensor inside the chamber – call authorized service.
• L0 – low temperature alarm (lower than temperature range set within the equipment– call authorized service.
• HI – high temperature alarm – call authorized service.
• EE – internal defect of the regulator – call authorized service.
• Ed – maximum defrosting time exceeded.
• DF – defrosting in progress (this is not an alarm signal).
The equipment is working too loud...– Make sure that:
• The equipment is standing stably and properly levelled.
• Furniture adjoining the equipment does not vibrate when self-contained compressor is working.
Noise’ made by the operating device is normal. The units are equipped with
ventilators, engines and compressors, which turn on and off automatically. Each
compressor makes certain noises when operating. These sounds are made by the
aggregate engine and by cooling agent flowing through the circuit. This
phenomenon constitutes a technical feature of cooling devices and does not signify
equipment failure.
Steam precipitation on glasses is normal in the event of high relative air humidity
exceeding 60% and does not require calling for service.