![Igloo ARBF4 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/igloo/arbf4/arbf4_instruction-manual_3948066012.webp)
REFRIGERATION LTD
12
www.igloorefrigeration.com
|
Ice Cream/ Gelato
5. MAINTENANCE
•
Do not use steel wool, abrasive cleaners, bleach or cleaners containing chlorine or sodium to clean the unit.
•
Do not use a pressure washer or water-jet to clean the unit.
•
The unit should be cleaned right after unpacking and before turning it on.
•
The unit should be cleaned with warm water and a mild soap.
•
Make sure to cover the fan motor to prevent moisture damage.
•
Door gaskets, shelves and supports should be cleaned on a regular basis.
•
Fan blades and guards should be cleaned with a soft moist cloth.
5.1 Cleaning and maintenance
•
All maintenance services need to be performed after disconnecting the
equipment from power supply!
•
Protect electrical components against any damage or water spillage.
•
Do not use water stream to clean the equipment, only a moist cloth.
•
Do not use any sharp objects to remove dirt!
It is recommended to make a break in the operation
once a month
in order to clean the interior, naturally defrost
the evaporator and clean the condenser.
Do not use mechanical agents to quicken the defrosting process!
A7
digital input alarm delay
0
min
0
199
A8
enable alarm “Ed” (end defrost by timeout)
0
-
0
1
Ac
set point dirty condenser alarm
60
°C
-50
250
AE
dirty condenser alarm differential temperature
3.0
°C
0.1
20
Acd
dirty condenser alarm delay
0
min
0
250
F0
enable evaporator fan control
1
-
0
1
F1
evaporator fan control set point
-2.0
°C
-50
130
F2
stop evaporator fan if compressor off
0
-
0
1
F3
evaporator fan status during defrost
1
-
0
1
Fd
post-dripping time
1
min
0
15
H0
serial address
1
-
0
207
H1
AUX output configuration
1
-
0
2
H2
enable keypad
1
-
0
2
H4
disable buzzer
0
0
1
H5
ID code (read-only)
-1
-
1
+199
EZY
restore the Default settings
0
0
0
1