WATER EXTRACTION

There are 2 ways to extract water from the dehumidifier:
Using the Water Tank:

•  When the water tank is full, the Tank Full indicator 

will illuminate.

•  Press the Stand-By button to switch the unit to 

standby mode and disconnect from the power 
source.

•  Grip the left and right handles of the water tank 

securely and slowly and carefully pull out the tank. 

Note: Take extra care to ensure not to tip the tank or spill the water onto the 

unit. The bottom of the tank is uneven, so care should be taken to not place the 
tank on the floor as it will fall over.

•  Dispose of the water inside the tank, dry the inside thoroughly and then 

carefully reinsert the tank back into the unit.

•  Reconnect the power source and press the Stand-By button to turn the 

dehumidifier back on. The appliance will resume dehumidification.

Note: Ensure the water tank is correctly installed in the dehumidifier otherwise 

the appliance will not function.

Continuous Draining:

•  Water can be automatically emptied into a floor drain by 

attaching a hose (included) to the Continuous Drainage 
outlet.

•  Switch the unit to standby mode and disconnect from the 

power.

•  Insert the hose (included) into the female end and lead the end 

of the hose to a floor drain or another suitable drainage facility.

•  Select the desired dehumidification mode and setting, continuous drainage 

will begin automatically.

Note: When the continuous draining function is not being used, the female end 

must be removed and the plastic cap replaced securely onto the Continuous 
Drainage outlet. If the plastic cap is not secured onto the outlet, water will leak 
from the back of the unit.

•  Remove the plastic cap from the Continuous Drainage outlet 

and attach the female threaded end securely.

•  Ensure there are no kinks or holes in the hose that will prevent the water 

from flowing freely.

•  Reconnect the power source and press the Stand-By button to turn the 

dehumidifier back on.

Содержание IG9851

Страница 1: ...tructions carefully before use and retain for future reference Before switching on your appliance always check for any damage which may have been caused in transit IG9851 Batch code 50 Litre Dehumidif...

Страница 2: ...on 6 Appliance Overview 7 Control Panel 8 Operating Instructions 9 Functions 10 11 Water Extraction 12 Cleaning and Maintenance 13 14 Trouble Shooting Guide 15 Error Codes 16 Fuse Replacement 17 Dispo...

Страница 3: ...damage Locate the unit on a dry flat and stable surface When storing or transporting the unit always keep in an upright position otherwise irreparable damage may be caused to the compressor if in dou...

Страница 4: ...e shall not be made by children Keep the appliance and its cord out of reach of children aged less than 8 years Children shall not play with the appliance This appliance can be used by persons with re...

Страница 5: ...rpose of the dehumidifier is to remove the excess moisture from the air to control the condensation in the home The optimum environmental conditions for the home are between 40 and 60 Relative Humidit...

Страница 6: ...Range 35 85 Filter Type Washable Dust Filter AirVolume 345m3 h 320m3 h Refrigerant R410A 290g Noise Level 51dB A 52dB A Net Weight 19 8Kg Product Dimensions mm H 616 x W 392 x D 282 Brand Igenix Produ...

Страница 7: ...Level Window Handle both sides Continuous Drain Outlet Casters Power Cord and Plug Power Cord Bracket Air Outlet Grille Air Filter Accessories located in the water tank Power Cord Bracket Female Thre...

Страница 8: ...he set humidity level or auto start stop time whilst selecting then shows the actual room humidity level Stand By Press this button to switch between standby mode and On Auto Press to select Automatic...

Страница 9: ...beep once and will remain in standby mode Press the Stand By button to switch on the appliance Note Make sure that the water tank is in the correct position If the Tank Full indicator illuminates rem...

Страница 10: ...he Manual button to begin dehumidification TURBO Press this button to alternate between the appliance s two fan speeds When the light above the button is illuminated the fan will run at a high speed t...

Страница 11: ...ED will automatically display the Relative Humidity of the room you can now select the desired function Once function is selected press the Timer button the Off light will then illuminate Use the Humi...

Страница 12: ...ctly installed in the dehumidifier otherwise the appliance will not function Continuous Draining Water can be automatically emptied into a floor drain by attaching a hose included to the Continuous Dr...

Страница 13: ...to remove all dirt Wash the filter in warm soapy water using a neutral detergent rinse well with clean water and then leave to dry Once the filter is thoroughly dry reinstall the air filter securely...

Страница 14: ...ss the Stand By button to switch the appliance to standby mode and disconnect from power source Empty and clean the water tank Clean the unit and the filters as per cleaning procedure above Cover the...

Страница 15: ...ted Make sure there is adequate clearance around the appliance and no blinds or furniture are blocking the sides of the humidifier There is excessive ventilation in the room Ensure all external doors...

Страница 16: ...ly Empty the water tank if required and ensure it is reinserted correctly EC Refrigerant leakage detected Call for service E3 Unit malfunction Unplug the unit and plug it back in again Eb Water tank i...

Страница 17: ...health and the environment The crossed out wheeled bin symbol on the product reminds you of your obligation that when you dispose of the appliance it must be separately collected Consumers should cont...

Страница 18: ...over accessories or consumable parts that require replacement under normal use This includes shelving dials filters belts and trays etc In the unlikely event of a breakdown please refer to the Trouble...

Страница 19: ...ble on our website www igenix co uk To register your product please complete all sections of the form below and return to us at the following address lgenix 38 Bluestem Road Ransomes Europark Ipswich...

Страница 20: ...claimer Igenix operate a policy of continual improvement and development We therefore reserve the right to change alter the specification and appearance of our appliances without prior notice All diag...

Отзывы: