background image

 

Fuse and Mains

 

Plug Replacement

 

 

This product is supplied  with a moulded plug,  which contains 
a 3A fuse. If you are simply replacing the fuse, you must use 
a 3A fuse which has been approved by ASTA to BS1362. 
 
If  the  plug  becomes  damaged,  a  new  plug  must  be  fitted. 
Replace the original plug with a 13A (BS1363) plug and make 
sure that it is fitted with an ASTA approved 3A fuse. 
 

Never

 use the moulded plug without the fuse cover fitted. 

 
To replace the plug: 
 
1.  Cut off the existing fitted plug and dispose of it. 
2.  The  wires  in  the  mains  lead  supplied  with  this  appliance 

are coloured in accordance with the following code: 
 
GREEN/YELLOW = EARTH (E) 
BLUE = NEUTRAL (N) 
BROWN = LIVE (L) 

 
This product 

MUST

 be earthed. 

 
As the colours of the wires in the mains lead may not correspond with the colour markings identifying the terminals 
in your new plug, proceed as follows: 
 
The wire which is coloured GREEN or YELLOW/GREEN must be connected to the terminal which is marked with 
the letter E or 

 symbol or a coloured GREEN or YELLOW/GREEN. 

 
The wire which is coloured BLUE must be connected to the terminal in the plug which is marked with the letter N or 
coloured BLACK or BLUE. 
 
The  wire  which  is  coloured  BROWN  must  be  connected  to  the  terminal  which  is  marked  with  the  letter  L  or 
coloured RED or BROWN. 
 
Ensure that the connections are tight and that no loose strands are left out of the terminals. 
 

IF  IN  DOUBT  CONSULT  A  QUALIFIED  ELECTRICIAN  –  DO  NOT  ATTEMPT  TO  CHANGE  THE  PLUG 
YOURSELF 

 
If the mains lead becomes damaged consult a qualified electrician. 

 
 
 
SPECIFICATION 

 

 

 
 
 

Model Number 

IG9805 

Voltage 

220-240V ~ 50Hz 

Moisture Removal 

50 Litres per day (30°C 80% RH) 

Power Input 

740W 

Operating Temperature 

5°C - 32 °C 

Noise Rating 

55dB 

Dimensions (H x W x D) 

600 x 388 x 282 mm 

Weight 

20 kg 

Green/Yellow 

(Earth) 

Blue 

(Neutral) 

Brown 

(Live) 

CABLE  
GRIP 

FUSE 

FUSE 

COVER

 

Содержание IG9805

Страница 1: ...50L D DEHUMIDIFIER Model Number IG9805 INSTRUCTIONS FOR USE Thank you for purchasing this product Please read these instructions carefully before use...

Страница 2: ...even surface Place the dehumidifier a least 30cm from the wall to dissipate heat properly Never use the appliance in the immediate surroundings of a bath shower swimming pool or greenhouse Always stor...

Страница 3: ...DEHUMIDIFIER AT A GLANCE CONTROL PANEL AT A GLANCE If the temperature is below 12 C the defrost function will activate...

Страница 4: ...rises above the level set The current room humidity will be displayed in the left LED screen as indicated in the diagram on the previous page PLEASE NOTE This dehumidifier operates using a compressor...

Страница 5: ...t is possible to operate this appliance with Continuous Drainage by fitting an 18 mm diameter hose supplied into the appliance Directions as follows PLEASE NOTE When using the continuous drainage feat...

Страница 6: ...oo big for operating capacity of the unit This unit is recommended for room size 165 220 m3 Unit is making loud noise Floor may be uneven Re position the unit on an even stable surface Leaking from th...

Страница 7: ...in your new plug proceed as follows The wire which is coloured GREEN or YELLOW GREEN must be connected to the terminal which is marked with the letter E or symbol or a coloured GREEN or YELLOW GREEN...

Страница 8: ...his guide are for illustration purposes only and may not apply to your particular situation No legal right or entitlements may be obtained from the description made in this manual View the range onlin...