iGenix IG9703 Скачать руководство пользователя страница 8

8

TROUBLE SHOOTING GUIDE

If you experience difficulties with the appliance, please check the suggestions below before contacting 
customer services:

Problem

Solution

The unit will not switch on

•  Check Trip Switch / Fuse
•  Check if the plug is connected to mains socket correctly
•  Check batteries in the remote control

Runs for a short while and then 
switches off

The unit has been running for a long 
period and then switches off 

•  The overheat protection has been activated to protect the  
   motor – turn unit off for a least 10 minutes and then switch  
   back on

•  Check if air outlet is blocked, if so remove obstacle  
•  Check if Timer function has been activated

Runs without cooling in Cool/Hum. 
mode and Empty Tank Indicator 
blinking

•  The water tank is empty and needs to be re-filled 
•  Check if the air filter is dirty – if so, clean
•  Check if air outlets or inlets are blocked

Water is leaking from unit when 
moving 

•  Drain the water tank – refer to Cleaning and Maintenance 
   on Page 7
•  Ensure rubber drainage plug is securely fitted in water tank 
   Ensure unit is located on a flat and even surface

The honeycomb filter is blocked 
with dust.

•  Remove the foreign matter

•  Pull down the honeycomb filter and clean it. 

The air inlet is blocked with dust

Fuse Replacement (Class II)

Remove the fuse cover with a small flat head screw driver. 
Take out the fuse and replace with a new fuse of the same 
Amp. Replace the fuse cover and push back into place.

Fuse Cover

MAINS PLUG FUSE REPLACEMENT

Содержание IG9703

Страница 1: ...tructions carefully before use and retain for future reference Before switching on your appliance always check for any damage which may have been caused in transit IG9703 Batch code Air Cooler with LE...

Страница 2: ...ried out by a qualified electrician Inadequate repairs may result in a major source of danger for the user and invalidate the warranty 2 Do not operate the unit if the plug or cord is damaged after it...

Страница 3: ...cides petrol etc whilst the unit is in use 19 Do not clean the unit by spraying it or immersing in water 20 Do not unplug the unit while it is working this could damage the electronic circuits Always...

Страница 4: ...CAL SPECIFICATION APPLIANCE OVERVIEW Model IG9703 SupplyVoltage 220 240V 50Hz Max Output 55W Max AirflowVolume 300m3 h Water tank capacity 6 Litres Net Weight 6 45kg The maximum room size recommended...

Страница 5: ...inimum of 2 minutes Attention Pay attention to the water line when filling the tank The water must not be higher than the MAX water line When humidifying the water must not be lower than the MIN water...

Страница 6: ...rt cooling fan is in high level running condition if the key is pressed continuously the air speed will switch in the following manner 6 Timer key When the air cooler is operating press the Timer key...

Страница 7: ...ve the Dust Filter With a mild detergent and a soft brush scrub the honeycomb filter clean with clear water and dry and then replace it to the unit Picture 1 After cleaning the Dust filter remove the...

Страница 8: ...as been activated Runs without cooling in Cool Hum mode and Empty Tank Indicator blinking The water tank is empty and needs to be re filled Check if the air filter is dirty if so clean Check if air ou...

Страница 9: ...collected separately in order to optimise the recovery and recycling of the materials they contain and reduce the impact on human health and the environment The crossed out wheeled bin symbol on the p...

Страница 10: ...over accessories or consumable parts that require replacement under normal use This includes shelving dials filters belts and trays etc In the unlikely event of a breakdown please refer to the Trouble...

Страница 11: ...ble on our website www igenix co uk To register your product please complete all sections of the form below and return to us at the following address lgenix 38 Bluestem Road Ransomes Europark Ipswich...

Страница 12: ...claimer Igenix operate a policy of continual improvement and development We therefore reserve the right to change alter the specification and appearance of our appliances without prior notice All diag...

Отзывы: