Caution 

This symbol and signal word refer to a potentially 
hazardous  situation  which  could  result  in 
personal  injury,  property  and  environmental 
damage if ignored. 

 

Caution 

This symbol and signal word refer to a potentially 
hazardous situation which could result in damage 
to the equipment if ignored. 

 

Info 

This  symbol  indicates  useful  information  and 
recommendations  as  well  as  measures  that  will 
prolong the value of your measuring and control 
system. 

1.2  Intended use of the device 

Use these installation and operating instructions, the identification on the rating 
plate  (see  5.6)  and  the  technical  data  sheet  to  check  whether  the  device  is 
suitable  for  the  intended  use/application.  The  device  complies  with  the 
requirements of the European Pressure Equipment Directive 2014/68/EU. 

 

The device may only be used to indicate fill levels on containers. 

The maximum values of the pressure and temperature range of the device must be checked 
before  installation.  If  the  maximum  allowable  operating  values  of  the  device  are  lower  than 
those of the system on which it is to be installed, protective instruments for the device, such 
as pressure reducers or similar, must be provided to avoid limit situations.  The device may 
only be used in accordance with the information in these installation and operating instructions 
or  for the parameters and applications agreed in the supply contract. (see rating plate, 5.6) 
The  operator  of  the  direct  water  level  indicator  is  obliged  to  familiarise  himself  on  the 
compatibility of the medium and the device. In case of doubt, contact the relevant installation 
manager or site manager. 

The correct installation position, alignment and flow direction of the device must be observed! 
Before  installing  the  IGEMA  product  on  boilers  or  containers,  it  is  essential  to  remove  all 
protective covers and, if necessary, the protective film from rating plates and sight glasses. 

 

 

 

Caution 

Содержание NA7-130

Страница 1: ...Edition 07 2021 D 06 B 51014 EN 00 INSTALLATION AND OPERATING INSTRUCTION NA7 45 NA7 130 Magnetic level indicator...

Страница 2: ...e Steam is our passion and we offer you the entire programme for the safe and economic operation of your plants especially in the steam and condensate sector Please read the installation and operating...

Страница 3: ...ons for this device 9 1 5 Exclusion of liability 9 2 Contents of packing 10 3 Important information 10 3 1 Intended use 10 4 Explanations 10 4 1 System description 10 4 2 Function 10 5 Technical data...

Страница 4: ...ment for retrofitting otherwise already pre installed 15 8 Electrical connection 15 8 1 Magnetic switch 16 8 2 Primary element 16 9 Commissioning 16 9 1 Adjustment of indicating flaps 16 9 2 Commissio...

Страница 5: ...9 11 1 Construction 19 11 2 Assembly 20 11 3 Commissioning 21 11 4 Maintenance 21 12 Spare parts 22 12 1 Magnetic level gauge 22 12 3 Drain valve 22 13 Decommissioning 23 13 1 Disposal 23 14 Warranty...

Страница 6: ...bove tasks IGEMA GmbH accepts no liability for damage to property or personal injury caused by unqualified persons or by failure to observe these installation and operating instructions If no sufficie...

Страница 7: ...s The maximum values of the pressure and temperature range of the device must be checked before installation If the maximum allowable operating values of the device are lower than those of the system...

Страница 8: ...been depressurised and that the pressure has been safely reduced to atmospheric pressure In principle no system should be regarded as unpressurized even if indicated by pressure measuring devices suc...

Страница 9: ...he applicable safety and environmental laws according to GGVSEB German ordinance on the national and international carriage of dangerous goods by road rail and inland waterways must always be observed...

Страница 10: ...ted magnetic system The product corresponding to the EU 2014 68 EU Applied standards as per EN 13445 EN 12952 EN 12953 AD 2000 or ASME Boiler 4 Explanations 4 1 System description The level gauge indi...

Страница 11: ...5 Technical data 5 1 Versions NA7 version flange cap 2 6m 6m Possible vent connections Vent cap Flange Flange with vent flange Possible drain connections Flange with drain flange Flange with drain val...

Страница 12: ...nsity the float is made of titan Other components in contact with the medium and pressure retaining components made of carbon steel according to DIN or ASME 5 4 Application limits Max all pressure PS...

Страница 13: ...arrow on the valve indicates the flow direction and must point towards the standpipe 2 Check mating dimensions between instrument nozzle and boiler nozzle Make sure that there are no magnetic material...

Страница 14: ...er magnetic system and the new gasket 2 2 are packed and fixed outside of the standpipe 2 when the unit is supplied Open cover flange 2 3 Carefully remove float packing Insert float with top heavy sid...

Страница 15: ...of the lower process connection is the reference point for the zero mark of the sensor marked in red see special data sheet and operating instruction for primary element MRK 8 Electrical connection On...

Страница 16: ...a sheet and operating instruction for primary element MRK 9 Commissioning Attention danger of life Unit may be hot during commissioning and during operation Customer can possibly provide safety device...

Страница 17: ...Maintenance When using viscous or crystallizing media clean standpipe 2 and float 2 1 inside in regular intervals and during boiler revision Attention danger of life Unit may be hot during commission...

Страница 18: ...use new gaskets 2 2 when assembling the unit Tighten bolts of cover flange standpipe in several steps using successively opposite diagonal tightening see table in chapter 10 2 until reaching tightenin...

Страница 19: ...onstruction AV500 AV520 Male thread G on input side Output side with cutting ring connection 12 as per DIN 2353 DS12 AV540 AV550 Male thread G on input side Output side with welding end On request oth...

Страница 20: ...5 Scraper rings 12 Plate OPEN CLOSED AUF ZU 6 Gland packing 13 Cap nut 7 Stuffing box 14 Drain connection 11 2 Assembly Ensure that drain piping has free outlet to atmosphere and is protected from pr...

Страница 21: ...ap 8 with open end wrench AF27 clockwisely until valve is tight Spindle 4 must stay movable Replace gland packing if re tightening of packing was not successful Replacement of packing Screw off cap nu...

Страница 22: ...ainless steel 3 1 Fixing element 15 00250 3 Indicating ledge AL1 G 10 130070 AL2 G 10 130072 AL3 G 10 130074 2 2 Flange sealing depending on the order 6 Screw plug 40 00329 40 00330 Sealing 40 00099 4...

Страница 23: ...priate treatment according to these mounting and operating instructions The warranty for wear and spare parts is restricted to material defects and construction faults The magnetic switches are wear p...

Страница 24: ...24 15 Manufacturer s Declaration...

Страница 25: ...25...

Страница 26: ...26...

Страница 27: ...27...

Страница 28: ...28 Antwerpener Str 1 Fon 49 2501 92424 0 48163 M nster Fax 49 2501 92424 99 Deutschland info igema com www igema com IGEMA GmbH...

Отзывы: