![ifs ES2402-V3 Series Скачать руководство пользователя страница 1](http://html1.mh-extra.com/html/ifs/es2402-v3-series/es2402-v3-series_quick-installation-manual_3887857001.webp)
P/N 1073661-EN
• REV
D
• ISS
03JUL22
1 / 4
ES2402
-
V3 Series Quick Installation Guide
Figure 1: ES2402-24P-2C-V3 managed switch
Figure 2: ES2402-16P-2C-V3 managed switch
Figure 3: ES2402-8P-2C-V3 managed switch
Package contents
Thank you for purchasing
an IFS
ES242
-
V
3
series
8/16/24-
Port 10/100TX 802.3at PoE +
2-
Port Gigabit TP/SFP combo
managed Ethernet switch.
Model numbers of these switches
are as follows: ES2402
-24P-2C-
V
3
, ES2402
-16P-2C-
V
3
, and
ES2402
-8P-2C-
V
3
.
Unless specified, the
term
“
managed switch
”
mentioned in this
quick installation guide
refers to the IFS
ES2402
-
V
3
series.
Open the box of the managed switch
and carefully unpack it.
The box should contain the following items:
T
he managed switch
× 1
Quick installation guide
× 1
Rubber feet
× 4
Two rack
-
mounting brackets with attachment screws
× 1
Power cord
× 1
SFP dust
-
proof
cap
× 2
If any of these are
missing or damaged, contact your dealer
immediately. If possible, retain the carton including the original
packing materials for
repacking
the product in case there is a
need to return it to us for repair.
Requirements
The managed switch
provide
s
a
remote login
interface for
management purposes. The following equipment is necessary
for further management:
Workstations running Windows
®
10 / 8 / 7 / 2008 /
Vista
/
2003 /
XP, MAC OS
X
or later, Linux, UNIX
,
or other
platforms are
compatible with TCP/IP protocols.
Workstations are
installed with Ethernet NIC (Network
Interface Card)
Ethernet port connection
Network cables
– U
se standard network (UTP) cables
with RJ45 connectors.
The above
workstations
have
a web browser
and
JAVA runtime environment plug
-
in
installed.
Note
: We
recommend using
Internet Explorer
11
.0 or
later
to
access the
managed switch.
If the web interface of the
managed switch
is not accessible, turn off the anti
-
virus
software or firewall and then try it again.
Starting web management
Th
is
section describes
how to start
up the
web
management
function for
the managed switch. Note that the managed switch
is configured through an Ethernet connection.
Ensure that the
manager computer is
set to
the same
IP subnet address.
For
example, if the default IP address of the managed switch
is
192.168.
0
.
100
, then the manager computer
should be set to
192.168.
0
.x
(where x is a number between 1 and 254, except
100), and the default subnet mask is 255.255.255.0.
Figure 4: IP management diagram
The switch interface can be accessed by the following
browsers: Internet Explorer (version 11.0 or later), Google