12
Remove the lock nut with the Ifö key or 12 mm cap
wrench.
Assembly instructions
Connect the inlet pipe with shut-off valve to the cistern
fittings. Route the water pipe through the cut-out in the
cistern lid and connect it to the shut-off valve. Make sure
that the inlet pipe is not in the way of the moving parts in
the fittings. Open for water.
NOTE! The cistern is designed for connection to water
pipes with an external diameter of 10.
1
2
3
4
5
Remove the lid.
Fit the wall box in the preferred location, a maximum of 2
meters from the centre of the cistern.
Thread the air hoses through the wall box, cut them to
suitable lengths and connect them to the brass nipples on
the button unit.
There are symbols on the cistern lid to prevent incor-
rect installation.
Screw the button unit onto the wall box and snap the wall
plate in place.
If the routing of the air hoses is hidden, a corrugated safety
pipe with an external diameter of 16 (electric conduit) can
be used.
This is not included.
Put the lid back on and screw down the lock nut until it
snaps.
Unsnap the bellows retainers on the cistern lid and
connect the air hoses to the bellows retainers’ brass
nipples. If necessary, also turn the bellows retainers 180
∞
in order to avoid unnecessary bends in the hoses. Refit
the bellows retainers.
Air hoses
Wall plate
2
1
2
3
1
2
Ifö key
Button unit
Wall box
13 (28)