3 Installation 

 

Mount only in a thick housing wall 
(e.g. transport thread).

 

Ensure that the signal direction is 
correct.

 

Ensure a safe vibration 
transmission and allow no elastic 
intermediate layers.

 

Select either the ¼"-28 UNF / M8 
(2) or the ¼"-28 UNF (3) threaded 
adapter and insert into the unit (1). 
Threaded adapters are supplied.

 

Tighten using a 3 mm Allen key. 
Tightening torque 8 Nm.

 

Drill and tap a hole at the mounting 
location:

 - M8 hole / depth min. 10 mm for 

threaded adapter ¼"-28 UNF/ M8.

 - Or ¼"-UNF hole / depth min. 

13 mm for threaded adapter 
¼"-28 UNF.

 

Tighten the unit with a tightening torque of 8 Nm.

4 Electrical connection

The unit must be connected by a qualified electrician. The national and 
international regulations for the installation of electrical equipment must be 
adhered to.

M12

4

1

2

3

L+

L

1

2

Pin 1: L+ (9.6...32 V DC)
Pin 2: 4...20 mA