8.7 Modbus TCP output function code
Function code
Description
Code 3 (dec)
read holding register
Code 6 (dec)
write single holding register
Code 16 (dec)
write multiple holding register
8.8 Modbus TCP exception response
The following exception codes are supported by VSE153
Function code
Name
Code 01
Illegal function
Code 02
Illegal data address
Code 03
Illegal data value
Code 04
Server device failure
9 Factory setting
9.1 General factory setting
Request
Parameter
Parameter set
none
Host name
no name assigned
IP address
192�168�0�1
TCP/IP port
3321
Subnet mask
255�255�255�0
Default gateway
192�168�0�244
MAC address
defined in the production process
9.2 Factory setting VSE153 - Modbus TCP
There is read and write access to the device settings� The following default values
are set by the factory:
Request
Parameter
IP address
192�168�0�100
Subnet mask
255�255�255�0
Gateway
192�168�0�244
Port
502