Diagnostic electronics with PROFINET-IO interface for vibration sensors

VSE150

5

3 Intended use

The device has been designed for process value monitoring, vibration monitoring and analysis of
dynamic signals.

Содержание VSE150

Страница 1: ...Operating instructions Diagnostic electronics with PROFINET IO interface for vibration sensors VSE150 11448192 00 03 2022 GB ...

Страница 2: ...ristics 11 7 4 PROFINET IO data model 12 7 5 PROFINET IO functions 16 7 5 1 I M functions 16 7 5 2 Shared Device 17 7 5 3 Reset to factory 17 7 6 PROFINET IO protocols 17 7 6 1 SNMP Simple Network Management Protocol 17 7 6 2 LLDP Link Layer Discovery Protocol 18 7 6 3 MRP Media Redundancy Protocol 18 7 6 4 DCP Discovery and Configuration Protocol 18 7 6 5 DCE RPC Distributed Computing Environment...

Страница 3: ...ating instructions or the technical data are not adhered to personal injury and or damage to property may occur The manufacturer assumes no liability or warranty for any consequences caused by tampering with the product or incorrect use by the operator Installation electrical connection set up operation and maintenance of the product must be carried out by qualified personnel authorised by the mac...

Страница 4: ...2 1 Symbols used Requirement Instructions Reaction result Designation of keys buttons or indications Cross reference Important note Non compliance may result in malfunction or interference Information Supplementary note 2 2 Warnings used ATTENTION Warning of damage to property CAUTION Warning of personal injury w Slight reversible injuries may result WARNING Warning of serious personal injury w De...

Страница 5: ...agnostic electronics with PROFINET IO interface for vibration sensors VSE150 5 3 Intended use The device has been designed for process value monitoring vibration monitoring and analysis of dynamic signals ...

Страница 6: ...rdware outputs can be configured as 2 x binary no nc or as 1 x analogue 0 4 20 mA and 1 x binary no nc The outputs can be used for time critical alarms e g machine protection response time up to 1 ms alarm output analogue value output of values measured by the diagnostic electronics The parameter setting interface TCP IP is used for communication between the diagnostic electronics and a PC e g VES...

Страница 7: ...e With objects in the time range v RMS a RMS and a Peak all 4 dynamic inputs are monitored simultaneously and without interruption The two outputs OU1 2 can be used for alarms The respective object states per sensor are also indicated via the 4 sensor LEDs The system LED displays the operating status of the device Parameter setting of monitoring tasks and alarming is done via the VES004 software T...

Страница 8: ...ct the bus cables from sources of electric magnetic interference and mechanical strain Observe the guidelines regarding electromagnetic compatibility EMC to keep mechanical risks and interference to a minimum 5 1 Sources of interference u Signal cables and power supply lines should not be installed in parallel u If necessary metal isolating segments should be placed between the power supply lines ...

Страница 9: ... values Adhere to the SELV criteria safety extra low voltage circuit electrically isolated from other circuits ungrounded when connecting the device so that no dangerous contact voltages will be applied to the sensor or transferred to the device If the DC circuit is to be grounded e g due to national regulations the PELV criteria must be adhered to protective extra low voltage circuit electrically...

Страница 10: ... c 10 15 19 23 IEPE x IEPE y IEPE z 11 14 18 22 IEPE 12 13 17 21 not connected n c Test The self test is only carried out via the Z axis u Connect both cables to the same terminal of a suitable evaluation unit e g VSExxx w Terminal 1 Supply L When using an IEPE input 24 V 20 Integrated Electronics Piezo Electric w The ground GND of the DC supply is directly connected with the ground GND of the sen...

Страница 11: ...name GSDML V2 32 IFM VSE150 20170424 xml file name GSDML V2 31 IFM VSE150 20170424 xml to be used with Step7 without support of the medium redun dancy This file is not certified by PNO PROFINET organisation The file name can differ in the date 20170424 xml 7 3 PROFINET IO characteristics Requirement Parameter Bit rate 100 Mbits s Supported protocols SNMP LLDP MRP DCP DCE RPC PTCP HTTP DAP module i...

Страница 12: ...inputs input name Real or DINT with factor Big or Little Endian 4 bytes Value of the signal connect ed to dynamic input sensor 1 4 if it has been config ured as a DC input Analogue inputs input name Real or DINT with factor Big or Little Endian 4 bytes Value of the signal connect ed to the analogue input IN1 IN2 External inputs input name Real or DINT with factor Big or Little Endian 4 bytes Value...

Страница 13: ...n 4 bytes Trigger rotational speed Reference value Real or DINT with factor Big or Little Endian 4 bytes Trigger reference value Warning alarm Real or DINT with factor Big or Little Endian 4 bytes Limit warning alarm rela tive Damage alarm Real or DINT with factor Big or Little Endian 4 bytes Limit damage alarm relative Baseline Real or DINT with factor Big or Little Endian Has a unit default SI u...

Страница 14: ...s tory entries of the object Alarms OUT1 OUT2 alarm name OUT1 Float or DINT with factor Big or Little Endian 4 bytes Configuration as analogue alarm output value of alarm output Byte 1 byte Configuration as digital alarm output alarm state Configuration as NC No alarm 1 Alarm 0 Configuration as NO No alarm 0 Alarm 1 alarm name OUT2 Byte 1 byte Alarm state Configuration as NC No alarm 1 Alarm 0 Con...

Страница 15: ... or Little Endian 4 bytes Checksum error counter of the internal device commu nication Read time DINT 4 bytes Read device time UTC PROFINET devices U32 0x00ssmmhh EtherNetIP devices U32 0x00hhmmss EtherCAT devices U32 0x00hhmmss MODBUS devices U32 0x00hhmmss Placeholder placeholder Byte xx byte Placeholder for fieldbus transmission Output PLC Source Data type Byte order Unit Data size Fieldbus rep...

Страница 16: ...dbus transmission 7 5 PROFINET IO functions The following chapters describe the supported PROFINET IO functions Functions not listed are not supported 7 5 1 I M functions The PROFINET IO device supports identification maintenance functions I M The general identification maintenance functions 0 3 can be read via slot 0 Requirement Parameter I M 0 Device identification only read access I M 1 3 Exten...

Страница 17: ...ared Device The device supports the Shared Device function It allows two controllers to simultaneously set up a cyclical connection to the device Requirement Parameter Shared Device Yes Max number of PROFINET IO controllers 2 controllers on input modules Access to output modules is always exclusive 7 5 3 Reset to factory The device supports the Reset to factory function This function supports the ...

Страница 18: ... Simple Network Management Protocol for exam ple 7 6 3 MRP Media Redundancy Protocol Requirement Parameter MRP Yes Description Media Redundancy Protocol Protocol to implement media redundancy Implements the switchover in case a transmission medium fails 7 6 4 DCP Discovery and Configuration Protocol Requirement Parameter DCP Yes Description Discovery and Configuration Protocol DCP distributes the ...

Страница 19: ...or changing the system mode of the diagnostic electronics to set up triggers an initialisation reboot of the fieldbus module The connection of the PLC master controller supervisor to the diagnostic electronics is interrupted It depends on the programming of the PLC how a connection loss is handled The LED behaviour is described in the chapter Operating and display elements ...

Страница 20: ... Host Name no name assigned IP address 192 168 0 1 TCP IP port 3321 Subnet mask 255 255 255 0 Default gateway 192 168 0 244 MAC address Is defined in the production process 8 2 IP settings PROFINET IO interface Requirement Parameter PROFINET IO device name no name assigned IP address No IP address assigned Subnet mask No subnet mask assigned Default gateway No default gateway assigned Device desig...

Страница 21: ...red application are bundled in a parameter set and transferred to the device For a detailed description of all parameters and possible configurations we refer you to the VES004 software manual The parameters of the PROFINET IO device are set via the PROFINET IO controller configuration tool Integrate the corresponding GSDML file of the device into the respective software tool STEP 7 hardware confi...

Страница 22: ...arning Red on damage alarm Green yellow flash alternately Teach process active Yellow red flash alternately no parameter set loaded LED 5 for system Green on System OK monitoring running Yellow on system OK no monitoring due to parameter setting self test or FFT mode Green yellow flash alternately monitoring not possible faulty parameter set Green red flash alternately System error EEPROM defectiv...

Страница 23: ...s written to the flash Green on Green on Firmware image was successfully written to the flash Orange briefly on Off Parameter set was successfully transferred Red Off No or faulty PROFINET IO communication Off Orange flashing PROFINET IO device detection active Red flashing Off Faulty PROFINET IO module configuration e g parameter setting of the input output modules of the device differ from param...

Страница 24: ...s maintenance free Only the manufacturer is allowed to repair the unit u After use dispose of the device in an environmentally friendly way in accordance with the applicable national regulations Cleaning the unit u Disconnect the unit from the voltage supply u Clean the unit from dirt using a soft chemically untreated and dry micro fibre cloth ...

Отзывы: