For units with metal housing (according to UL 508): 

 

Keep a distance of at least 12.7 mm between the sensor and non-

insulated metal material.

For further information please refer to www.ifm.com 

 

→ General information about installation and operation.

4  Electrical connection

 

Disconnect power.

 

► Connect unit (depending on the type selected):

BK: black

BN: brown

BU: blue

WH: white

BN
WH

BK
BU

4

1

3

2

OUT2

L+

L

OUT1

• OUT1:  switching output / IO-Link

• OUT2: switching output

colours to DIN EN 60947-5-2

5  Settings

The unit and the parameters are set via the IO-Link interface (

→ 5.1) or the 

teach button (

→ 5.2).

5.1  IO-Link

This unit has an IO-Link communication interface which enables direct access to 

process and diagnostic data. In addition it is possible to set the parameters of the 

unit while it is in operation. Operation of the unit via an IO-Link interface requires 

an IO-Link master.
With a PC, suitable IO-Link software and an IO-Link adapter cable communication 

is possible when the system is not in operation.
The IODDs necessary for the configuration of the unit, detailed information about 

process data structure, diagnostic information, parameter addresses and the 

necessary information about the required IO-Link hardware and software can be 

found at www.ifm.com.

Содержание UGT203

Страница 1: ...Operating instructions Ultrasonic diffuse reflection sensor with IO Link UGT203 UGT206 UGT509 UGT512 80275568 00 05 2018 UK ...

Страница 2: ... caused by tampering with the product or incorrect use by the operator Installation electrical connection set up operation and maintenance of the product must be carried out by qualified personnel authorised by the machine operator Protect units and cables against damage 2 Functions and features Ultrasonic sensor for monitoring levels and detecting objects 3 Installation 3 4 1 2 Secure the unit to...

Страница 3: ...are set via the IO Link interface 5 1 or the teach button 5 2 5 1 IO Link This unit has an IO Link communication interface which enables direct access to process and diagnostic data In addition it is possible to set the parameters of the unit while it is in operation Operation of the unit via an IO Link interface requires an IO Link master With a PC suitable IO Link software and an IO Link adapter...

Страница 4: ...w status LEDs 1 2 flash 2 5 Hz P1 setting is completed Position the object in P2 Fig 1 or 2 Press the teach button for 1 s Yellow status LEDs 1 2 flash briefly 4 Hz P2 setting is completed 5 2 3 Invert output response Press the teach button for 6 s Yellow status LEDs 1 2 flash 10 Hz Yellow status LEDs 1 2 flash briefly 4 Hz Output function is inverted 5 2 4 Restore factory setting Align the unit s...

Страница 5: ...s Complementary switching outputs 1 1 B P2 P1 1 0 0 3 4 2 B P1 P2 2 1 0 1 0 1 3 4 Inverted switching outputs Inverted switching outputs 1 1 B P2 P1 1 0 0 2 3 4 1 1 B P1 P2 1 0 0 2 3 4 1 output response 2 distance to the object 3 OUT1 switching output 4 OUT2 switching output B blind zone P taught position T teach button Technical data and further information at www ifm com ...

Отзывы: