Vortex flow meter

12

Parameter

Explanation

FSPx

Frequency start point for OUTx = Lower measured value from which a frequency signal is output
(only for temperature measurement).

FEPx

Frequency end point for OUTx = Upper measured value at which the frequency signal set under
FrPx is output.

FrPx

Frequency signal that is output when the upper measured value (MEW or FEPx) is reached.

EF

Change to the EF (extended functions) submenu

ou2

ou1

Hno Hnc Fno Fnc FRQ

dS1

dr1

dS2

uni

P-n

dAP

rES

CFG

- - - -

Info

FOU1

FOU2

OFF

On

OU

OFF

On

OU

PnP nPn

m

3

/h

l/min

Hno Hnc Fno Fnc FRQ

dr2

SEL2

FLOW TEMP

DIS

MEM

----

----

----

----

----

EF

CFG

Main menu

Process value display

Fig. 6: Configuration [CFG] menu

Parameter

Explanation

rES

Reset to factory settings

Info

Display of the device information

CFG

Change to the CFG (configuration) submenu

MEM

Change to the MEM (memory) submenu

DIS

Change to the DIS (display) submenu.

oux

Output configuration for output OUTx (e.g. switching output with hysteresis function)

dSx

Switch-on delay for switching output OUTx in seconds

drx

Switch-off delay for switching output OUTx in seconds

uni

Standard unit of measurement for flow

P-n

Output polarity for the switching outputs

dAP

[dAP] = damping constant in seconds (63 % rise time τ).

FOUx

Behaviour of output OUTx in case of an error

SELx

Process value for output OUTx

Содержание SV0527

Страница 1: ...Operating instructions Vortex flow meter SV0527 SV0528 SV0529 11496698 00 12 2022 GB...

Страница 2: ...ntended use 5 3 1 Application area 5 4 Function 6 5 Installation 7 5 1 Non recommended installation position 8 6 Electrical connection 9 7 Operating and display elements 10 8 Menu 11 8 1 Main menu and...

Страница 3: ...on the unit packaging or at www ifm com 1 1 Symbols used Requirement Instructions Reaction result Designation of keys buttons or indications Cross reference Important note Non compliance may result i...

Страница 4: ...tem Read this document before setting up the product and keep it during the entire service life The product must be suitable for the corresponding applications and environmental conditions without any...

Страница 5: ...flow quantity time and medium temperature 3 1 Application area Water Hydrous media deionised water cooling water Pressure Equipment Directive PED The units comply with the Pressure Equipment Directiv...

Страница 6: ...n be operated in SIO mode standard input output or in IO Link mode The basic operation mode is SIO When connected to an IO Link master the device automatically switches to IO Link mode Additional manu...

Страница 7: ...like affect the function of the unit u Adhere to the distances between sensor and interference Disturbance Inlet pipe length 1 Outlet pipe length 2 Non ideal bend 5 x DN 1 x DN Ideal bend R 1 8 x D N...

Страница 8: ...le accessories at www ifm com 5 1 Non recommended installation position Directly in front of a falling pipe In a falling pipe Directly in front of the spout of a pipe Directly in front of a valve On t...

Страница 9: ...t Voltage supply according to SELV PELV u Disconnect power u Connect the unit as follows L 1 BN 2 WH 4 BK 3 BU OUT1 IO Link OUT2 L 4 3 2 1 Fig 2 Wiring diagram colours to DIN EN 60947 5 2 BK black BN...

Страница 10: ...rtex flow meter 10 7 Operating and display elements 2 3 4 1 Fig 3 Operating and display elements 1 Switching status LED for OUT1 2 Switching status LED for OUT2 3 TFT display 4 Keys for changing views...

Страница 11: ...1 Main menu and submenus The displayed parameters change when the factory setting is changed The following menu displays show the maximum available parameters EF rP1 SP1 FH1 FL1 FEP1 FrP1 SP2 rP2 CFG...

Страница 12: ...in Hno Hnc Fno Fnc FRQ dr2 SEL2 FLOW TEMP DIS MEM EF CFG Main menu Process value display Fig 6 Configuration CFG menu Parameter Explanation rES Reset to factory settings Info Display of the device inf...

Страница 13: ...EM DIS coL F OFF rEd r cF G cF GrEn r1ou G1ou cFH F cFL F cFH T cFL T diS L L1 L2 diS B diS U diS R d1 d2 d3 0 90 180 270 25 50 75 100 OFF coL T OFF rEd r cF G cF GrEn r2ou G2ou EF DIS Main menu Fig 8...

Страница 14: ...527 SV0528 SV0529 Vortex flow meter 14 Parameter Explanation col T Font colour for temperature cFH T Upper limit value for colour change temperature cFL T Lower limit value for colour change temperatu...

Страница 15: ...your hands u Use another object e g a ballpoint pen to carry out settings on the unit Parameter setting process in general Intent Action Change from the process value display to the main menu Change t...

Страница 16: ...SV0527 SV0528 SV0529 Vortex flow meter 16 u Change parameter settings in the software u Write parameter settings to the unit Notes on parameter setting Manual of the parameter setting software...

Страница 17: ...38 5 MEW FH2 FLOW TEMP 40 MEW FL2 FLOW TEMP 38 5 MEW FSP2 TEMP 0 MEW FEP2 FLOW TEMP 100 FrP2 FLOW TEMP 100 Hz ou1 FLOW Hno ou2 FLOW TEMP Hno FOU1 FLOW OFF FOU1 FLOW TEMP OFF SEL2 FLOW TEMP FLOW coL F...

Отзывы: