10.3  Settings for consumed quantity monitoring
10.3.1  Quantity monitoring by pulse output (OUT1)

 

Select [ou1] and set ImP�

 

Select [ImPR] and set YES�

 

Select [ImPS] and set the volumetric flow quantity at which 1 pulse is provided 

(→ 

10�3�3)

10.3.2  Quantity monitoring by preset counter (OUT1)

 

Select [ou1] and set ImP�

 

Select [ImPR] and set no�

 

Select [ImPS] and set the volumetric flow quantity at which output 1 switches 

(→ 

10�3�3)

10.3.3  Pulse value

 

Select [ou1] and set the consumed quantity monitoring: 

 

→ 10.3.1

 or 

→ 10.3.2

 

Select [ImPS]�

 

Press [Set] briefly�

 

> The currently set value is displayed�

 

Keep [Set] pressed until "

cccc

" is displayed�

 

Press [Set] to select the setting range�

 

> With each press of the pushbutton the display changes to the next setting range (deci-

mal point shifts and / or LED* changes)�

 

Press [Mode/Enter] to confirm the setting range�

 

Press [Set] until the requested numerical value is displayed�

 

Press [Mode/Enter] briefly�

* LED 1���6 

→ 7 Operating and display elements

10.3.4  Manual counter reset

 

Select [rTo] and set rES�T�

 

> The counter is reset to zero�

10.3.5  Time-controlled counter reset

 

Select [rTo] and set the requested value (intervals of hours, days or weeks)�

 

> The counter is reset automatically with the value now set� 

Содержание SM4x00

Страница 1: ...Operating instructions Magnetic inductive flow meter SM4x00 SM6x00 SM7x00 SM8x00 SM6x01 SM7x01 SM8x01 80224865 00 02 2018 UK ...

Страница 2: ... output 8 4 3 3 Consumed quantity monitoring via preset counter 9 4 4 Switching function 10 4 5 Analogue function 11 4 6 Measured value damping dAP 13 4 7 Start up delay dST 13 4 8 Low flow cut off LFC 15 4 9 IO Link 15 5 Mounting 16 5 1 Recommended installation position 16 5 2 Not recommended installation position 17 5 3 Grounding 18 5 4 Installation in pipes 19 6 Electrical connection 20 7 Opera...

Страница 3: ...gnal 30 10 4 Settings for temperature monitoring 30 10 4 1 Limit monitoring temperature OUT2 30 10 4 2 Analogue output temperature OUT2 30 10 5 User settings optional 30 10 5 1 Standard unit of measurement for volumetric flow 30 10 5 2 Standard display 31 10 5 3 Output logic 31 10 5 4 Start up delay 31 10 5 5 Measured value damping 31 10 5 6 Error behaviour of the outputs 31 10 5 7 Low flow cut of...

Страница 4: ...e the product for permissible media Technical data If the operating instructions or the technical data are not adhered to personal injury and or damage to property may occur The manufacturer assumes no liability or warranty for any consequences caused by tampering with the product or incorrect use by the operator Installation electrical connection set up operation and maintenance of the unit must ...

Страница 5: ...process categories volumetric flow consumed quantity medium temperature Pressure Equipment Directive PED The units comply with the Pressure Equipment Directive and are designed and manufactured for group 2 fluids in accordance with the sound engineering prac tice Use of group 1 fluids on request Application area Conductive liquids with the following properties Conductivity 20 µS cm Viscosity 70 mm...

Страница 6: ...gue signal for volumetric flow quantity 10 2 3 Analogue signal for temperature 10 4 2 Switching signal for direction of flow 10 2 4 Input for external counter reset signal InD 10 3 7 4 2 Direction of flow In addition to the flow velocity and the volumetric flow quantity the unit also de tects the direction of flow 4 2 1 Determination of the direction of flow Fdir An arrow with the text flow direct...

Страница 7: ...n negative direction of flow LFC Minimum volumetric flow quantity in positive direction of flow LFC Minimum volumetric flow quantity in negative direction of flow Positive direction of flow marked direction of flow with the factory setting marked by the arrow on the unit or after change via Fdir marked by the attached label 4 2 1 4 3 Consumed quantity monitoring ImP The unit has an internal quanti...

Страница 8: ...reset using one of the above mentioned processes an automatic reset will be made when the maximum volumetric flow quantity that can be displayed is exceeded overflow Taking into consideration the direction of flow The quantity meter takes account of the flow direction for totalisation The fol lowing counting methods can be defined via the parameter FPro 10 5 8 FPro Counting method 0 Negative flow ...

Страница 9: ...ble which can be set via the parameter rTo rTo Output Counter reset OFF 10 3 6 OUT1 switches when the volumetric flow quantity set with ImPS has been reached The preset counter is only reset when a manual reset is made 10 3 4 or when the maximum display range has been exceeded 1 2 h 1 2 d 1 2 w 10 3 5 OUT1 switches when the volumetric flow quantity set with ImPS is reached within the set time The ...

Страница 10: ... NC normally closed SP upper limit rP lower limit FE window Fno window NO normally open Fnc window NC normally closed When the hysteresis function is set the set point SP is defined first and then the reset point rP which must have a lower value If only the set point is changed the reset point remains constant When set to the window function the upper limit SP and the lower limit rP have a fixed h...

Страница 11: ...t of an internal error the current or voltage signals indicated in Figure 1 are provided The measuring range is scalable ASP2 determines at which measured value the output signal is 4 mA or 0 V AEP2 determines at which measured value the output signal is 20 mA or 10 V Minimum distance between ASP2 and AEP2 20 of the final value of the measuring range MAW Initial value of the measuring range For no...

Страница 12: ...isplay range cr UL Below the detection zone error cr OL Above the detection zone error FOU On Default setting at which the analogue signal goes to the upper final value in case of an error FOU OFF Default setting at which the analogue signal goes to the lower final value in case of an error The type of error is displayed cr UL cr OL Err 12 1 Analogue signal voltage or current 2 Measured value flow...

Страница 13: ...utputs of the volumetric flow monitoring If the start up delay is active dST 0 note As soon as the volumetric flow exceeds the LFC value 4 8 the following processes are carried out The start up delay is activated The outputs switch as programmed ON for NO function OFF for NC function After the start of the start up delay there are 3 options 1 The volumetric flow increases quickly and reaches the s...

Страница 14: ...dST starts output becomes active 2 dST elapsed Q reached SP Output remains active 3 Q below SP but above rP Output remains active 4 Q below rP Output is reset 5 Q reaches again LFC dST starts output becomes active 6 dST elapsed Q has not reached SP Output is reset 7 Q reaches SP Output becomes active ...

Страница 15: ...Q reaches good range Output becomes active 4 8 Low flow cut off LFC With the function Low Flow cut off small volumetric flow quantities can be sup pressed 10 5 7 Flows below the LFC value are evaluated by the sensor as standstill Q 0 4 9 IO Link This unit has an IO Link communication interface which enables direct access to process and diagnostic data In addition it is possible to set the paramete...

Страница 16: ...ing label to the sensor cable The unit can be installed independently of the orientation if the following is ensured No air bubbles can form in the pipe system The pipes are always completely filled 5 1 Recommended installation position Install the unit so that the measuring pipe is always completely filled Arrange for inlet and outlet pipe lengths Disturbances caused by bends valves reductions et...

Страница 17: ...17 UK Install in front of or in a rising pipe F F 5 2 Not recommended installation position Avoid the following installation positions F F Directly in front of a falling pipe In a falling pipe ...

Страница 18: ...ide of a pump F At the highest point of the pipe system F flow direction 5 3 Grounding If installed in an ungrounded pipe system e g plastic pipes the unit must be grounded functional earth Ground brackets for the M12 connector are available as accessories www ifm com ...

Страница 19: ... for the application 2 Screw the adapter B into the pipe A 3 Place the seals C and install the unit according to the marked flow direction 4 Screw the adapter B with the threads D until it is hand tight 5 Tighten the two adapters in opposite direction Tightening torque SM6 SM7 SM8 30 Nm SM4 15 Nm After installation air bubbles in the system can affect the measurement Corrective measures Rinse the ...

Страница 20: ...ording to EN 50178 SELV PELV Disconnect power Connect the unit as follows 4 3 2 1 BK black BN brown BU blue WH white BN WH BK BU 4 1 3 2 OUT2 L L OUT1 Colours to DIN EN 60947 5 2 Sample circuits 2 x positive switching 2 x negative switching L L 3 BU 4 BK 2 WH 1 BN L L 3 BU 4 BK 2 WH 1 BN 1 x positive switching 1 x analogue 1 x negative switching 1 x analogue L L 3 BU 4 BK 2 WH 1 BN L L 3 BU 4 BK 2...

Страница 21: ...Switching signal quantity meter reached preset value Switching signal for direction of flow IO Link Pin 2 OUT2 InD Switching signal limits for volumetric flow Switching signal limits for temperature Analogue signal for volumetric flow quantity Analogue signal for temperature Switching signal for direction of flow Input for external counter reset signal InD ...

Страница 22: ...nsumed quantity meter reading before the last reset l l 4 m3 m3 4 6 m3 x 103 m3 x 103 5 Current medium temperature C C SMxx01 LED Process value display Unit 1 Current flow volume per minute gpm 2 Current flow volume per hour gph 3 Current consumed quantity meter reading since the last reset Totaliser gal 3 5 gal x 103 3 6 gal x 106 3 Consumed quantity meter reading before the last reset gal 3 5 ga...

Страница 23: ...ric flow quantity with setting SELd FLOW Meter reading of the totaliser with setting SELd TOTL Current medium temperature with setting SELd TEMP Parameters and parameter values 10 Mode Enter button Change from the RUN mode to the main menu Select parameters Acknowledge the set parameter value 11 Set button Change parameter values hold button pressed Change of the display unit in the normal operati...

Страница 24: ...x103 m3 x103 m3 ml min SM4x00 l h l m C Mode Enter Set Hi F Lo F Hi T Lo T FOU1 FOU2 dSt P n dAP rTo diS uni SELd SEL2 LFC FPro Fdir rES EF gpm SMxx01 gph F gal galx103 galx106 Parameters with white background are indicated in case of factory setting 14 Parame ters with grey background are indicated in case of changes of the preset for ou1 and ou2 ...

Страница 25: ...umetric flow or tempera ture on OUT2 SP2 rP2 Maximum minimum value for volumetric flow or temperature on OUT2 DIn2 Configuration of the input for external meter reset signal HIGH EDG LOW EDG 10 3 7 EF Extended functions opening of the lower menu level Hi F Hi T Maximum value memory for volumetric flow temperature Lo F Lo T Minimum value memory for volumetric flow temperature FOU1 FOU2 Behaviour of...

Страница 26: ...th normally open function Hno Fno OFF with normally closed function Hnc Fnc ON for detection of direction dir F If output 2 is configured as analogue output the output signal is at 20 mA current output or 10 V voltage output 10 Parameter setting Parameters can be set before installation or during operation If you change parameters during operation this will influence the function Ensure that there...

Страница 27: ...hange the setting mode Set 5 s 4 Modification of the parameter value incrementally by pressing once continuously by keeping the button pressed To reduce the value let the display move to the maximum setting value Then the cycle starts again at the minimum setting value Set 5 Acknowledge the set parameter value Mode Enter 6 Return to the RUN mode 30 seconds timeout or Mode Enter until the RUN mode ...

Страница 28: ... and set the switching function Hno Hnc Fno or Fnc Select SP1 and set the upper limit of the volumetric flow Select rP1 and set the lower limit of the volumetric flow 10 2 2 Limit monitoring volumetric flow OUT2 Select SEL2 and set FLOW Select ou2 and set the switching function Hno Hnc Fno or Fnc Select SP2 and set the upper limit of the volumetric flow Select rP2 and set the lower limit of the vo...

Страница 29: ... 10 3 2 Select ImPS Press Set briefly The currently set value is displayed Keep Set pressed until cccc is displayed Press Set to select the setting range With each press of the pushbutton the display changes to the next setting range deci mal point shifts and or LED changes Press Mode Enter to confirm the setting range Press Set until the requested numerical value is displayed Press Mode Enter bri...

Страница 30: ...1 and set the upper temperature limit Select rP2 and set the lower temperature limit 10 4 2 Analogue output temperature OUT2 Select SEL2 and set TEMP Select ou2 and set the analogue function I 4 20 mA or U 0 10 V Select ASP2 and set the temperature value at which the minimum current or voltage value is provided Select AEP2 and set the temperature value at which the maximum current or voltage value...

Страница 31: ...are displayed even if the display is deactivated 10 5 3 Output logic Select P n and set PnP or nPn 10 5 4 Start up delay Select dST and set the numerical value in seconds 10 5 5 Measured value damping Select dAP and set the damping constant in seconds τ value 63 10 5 6 Error behaviour of the outputs Select FOU1 and set the value On Output 1 switches ON in case of a fault OFF Output 1 switches OFF ...

Страница 32: ...s 10 6 1 Read min max values Read minimum or maximum measured values Select Hi x or Lo x Hi F maximum volumetric flow Lo F minimum volumetric flow Hi T maximum temperature Lo T minimum temperature Delete memory Select Hi x or Lo x Press and hold Set until is displayed Briefly press Mode Enter It makes sense to delete the memories as soon as the unit operates under normal operating conditions for t...

Страница 33: ...w quantity 10 5 1 11 2 Changing the process value display in the RUN mode Briefly press Set in the RUN mode Press the pushbutton to move to the next display unit The unit displays the current measured value in the selected display unit for approx 30 s the corresponding indicator LED lights 7 11 3 Reading the set parameters Briefly press Mode Enter to scroll through the parameters Briefly press Set...

Страница 34: ...arameter setting via IO Link communica tion active Finish parameter setting via IO Link communication S Loc Warning Setting buttons locked via parameter software parameter change rejected Unlock the unit via IO Link interface using the parame ter setting software UL Warning Below the display range Current value between 130 120 MEW Temperature value between 50 40 C or 58 40 F Check flow range tempe...

Страница 35: ...ircuit or excessive current SC2 Warning Switching status LED for OUT2 flashing short circuit OUT2 Check switching output OUT2 for short circuit or excessive current SC Warning Switching status LEDs for OUT1 and OUT2 flashing short circuit in both outputs Check switching outputs OUT1 and OUT2 for short circuit or excessive current MEW final value of the measuring range 13 Technical data Technical d...

Страница 36: ...1 19 5 ImPS SM4x00 0 001 l SMxx00 0 01 l SMxx01 0 01 gal ImPR Yes OU1 Hno OU2 I SP2 FLOW 40 rP2 FLOW 39 5 SP2 TEMP 40 rP2 TEMP 39 5 ASP2 FLOW 0 AEP2 FLOW 100 ASP2 TEMP 0 ASP2 TEMP 100 Fdir FPro 0 LFC SM4x00 20 ml SMxx00 SMxx01 MAW DIn2 EDG FOU1 OFF FOU2 OFF dST 0 P n PnP ...

Страница 37: ... SM6 7 8 d3 SM4 d2 Uni SM4x00 ml min SMxx00 l min SMxx01 gpm SELd FLOW SEL2 FLOW MAW Initial value of the measuring range The percentage values refer to the final value of the measuring range Technical data approvals accessories and further information at www ifm com ...