5
UK
The objects to be detected are to move transversally to
the lens of the sensor
►
In case of other directions of movement it should be
tested before whether safe switching is guaranteed
4.1 Mounting positions
For demanding applications (small distance between the object and the back
-
ground) we recommend the following mounting positions:
Reflective background
►
In case of highly reflective background surfaces and
less reflective object surfaces the sensor should be
mounted vertically to the background surface
Reflective object
►
In case of highly reflective object surfaces and less
reflective background surfaces the sensor should be
mounted at an angle of approx 5 to 10°