4 Installation
1
1
transmitter
receiver
1: LED
► Secure the receiver (OGE7xx) to a bracket.
► Align the transmitter (OGS7xx) to the receiver and secure it in the same way.
Maximum range is only possible with precise alignment.
5 Electrical connection
The unit must be connected by a qualified electrician.
►
The national and international regulations for the installation of
electrical equipment must be adhered to.
►
Voltage supply according to EN 50178.
►
Disconnect power.
►
Connect the unit as follows:
Transmitter (OGS7xx) DC
1
3
L+
L
pin 1 = L+ (10...36 V DC)
(pin 2: not used)
pin 3 = L-
(pin 4: not used)
Receiver (OGE7xx) DC PNP
pin 1 = L+ (10...36 V DC)
(pin 2: not used)
pin 3 = L-
pin 4: load (PNP, 200 mA)