![IFM O6P7 Series Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/ifm/o6p7-series/o6p7-series_operating-instructions-manual_4040501009.webp)
9
UK
Parameter
name
Values
Description
Default
Teach SP1 TP2
2� Part of the teach sequence to set switch
point SP1 by teach without object� The
second part of the teach sequence has to
be carried out after the first part�
N� A�
TI Result�State - Idle
- SP1
Success
- Wait for
com-
mand
- Busy
- Error
- Custom
Teach-in status; after successful teach the
value "SP1 Success" is displayed�
N� A�
Sequence
modulation
- OFF
- AUTo
OFF: anti-crosstalk function off
AUTo: anti-crosstalk function on
OFF
SSC1 Config�
Logic
High
active
Low
active
Switch point logic, status for detected object
(High: light-on mode / normally open, Low:
dark-on mode / normally closed)
→
Data
sheet value
"Output func-
tion"
SSC1 switch-on
delay
0 ��� 2
Start-up delay; step increment 0�1 s
0
SSC1 switch-off
delay
0 ��� 2
Switch-off delay; step increment 0�1 s
0
Excess gain
0 ��� 5
Excess gain at receiver�
N� A�
Transmitter
configuration
- On
- Off
Configuration transmitted light on / off
On
Number of
power cycles
0 ���
65535
Number of switching operations (power up)
of the sensor
N� A�
Operating hours 0 ���
65535
Operating hours
N� A�