background image

5

UK

7.3 Setting of the maximum sensitivity

 

Align the sensor so that no light is reflected.

The sensor is to switch when the object is detected

 

First press [OUT on] and then [OUT off].

The sensor is to switch when the object is not detected

 

First press [OUT off], then [OUT on].

7.4 Programming unsuccessful

 

> The LED flashes quickly, 8 Hz.
•  Measured value difference too small.
•  Max. programming time of 15 min. exceeded.

7.5 Electronic lock

Lock or unlock the buttons

 

Press [OUT on] and [OUT off] simultaneously for 10 s.

 

> Acknowledgement is indicated by a change of the LED status.

8 Operation

 

Check whether the unit operates correctly.

 

> The LED lights when the switching output is switched.

9 Maintenance, repair and disposal

 

Keep the front pane of the sensor free from soiling.

 

For cleaning do not use any solvents or cleaning agents which could damage 

the plastic material.

Technical data and further information at

www.ifm.com