5
UK
7.3 Setting of the maximum sensitivity
►
Align the sensor so that no light is reflected.
The sensor is to switch when the object is detected
►
First press [OUT on] and then [OUT off].
The sensor is to switch when the object is not detected
►
First press [OUT off], then [OUT on].
7.4 Programming unsuccessful
> The LED flashes quickly, 8 Hz.
• Measured value difference too small.
• Max. programming time of 15 min. exceeded.
7.5 Electronic lock
Lock or unlock the buttons
►
Press [OUT on] and [OUT off] simultaneously for 10 s.
> Acknowledgement is indicated by a change of the LED status.
8 Operation
►
Check whether the unit operates correctly.
> The LED lights when the switching output is switched.
9 Maintenance, repair and disposal
►
Keep the front pane of the sensor free from soiling.
►
For cleaning do not use any solvents or cleaning agents which could damage
the plastic material.
Technical data and further information at
www.ifm.com