5 Mounting
Depending on the application and surface of the object to be monitored, the unit can be installed in
front of or above the object.
u
Fasten the unit to a bracket via the two threaded holes present on the unit. Tightening torque max.
2.1 Nm.
u
Align the unit to the centre of the object’s optical axis.
Information about available accessories at www.ifm.com
5.1 Installation instructions
Storage at high humidity can lead to fogging of the front glass after switch-on, which can affect the
functioning of the unit.
u
Do not exceed the following limits:
Temperature
Maximum recommended relative humidity
25 °C
75 %
30 °C
72 %
35 °C
70 %
40 °C
67 %
u
Avoid back light, scattered light and changing light conditions. Sunlight hitting the lens or the scene
to be monitored may cause interference.
u
Ensure mechanical decoupling when installing the unit to prevent the sensor from vibrating.
u
Avoid installation in heavily polluting areas of the machine.
Units mounted side by side can interfere with each other when exposed to active lighting
simultaneously.
u
Ensure constant external illumination or trigger the units one after the other.
u
Make sure that the pressure compensation element on the bottom side of the unit is not covered.
1
Fig. 4: Pressure compensation element (1)