![IFM O1D100 series Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/ifm/o1d100-series/o1d100-series_manual_3993429004.webp)
TEL: 800-441-8246 • FAX: 800-329-0436
www.ifmefector.com
10/05
Lit. No. B41005
Measuring
range
[mm]
Repeatability* [mm]
Accuracy* [mm]
white (90%
remission)
grey (18%
remission)
white (90%
remission)
grey (18%
remission)
200...1000
10 (±5)
15 (±7.5)
±15
±18
1000...2000
11 (±5.5)
20 (±10)
±15
±20
2000...4000
35 (±17.5)
45 (±22.5)
±25
±32
4000...6000
55 (±27.5)
80 (±40)
±35
±50
6000...10,000
120 (±60)
–
±70
–
* The values specified for repeatability and accuracy refer to a sampling
frequency of 50 Hz. At a lower sampling frequency, which is adjustable
on the unit, these values will be lower. View the calculation tool at
www.ifmefector.com/ifmus/web/pmd_5.htm
Distance to target
(shown on sensor display)
[mm]
200...1000
1,000...2000
2,000...4000
4,000...6000
6,000...10,000
Minimum distance from
target to background
[mm]
38
50
113
200
300
For background suppression applications
The following chart shows the minimum distance required
between target and background