Electronic level sensor
LR3009
25
w
The numerical values are incremented continuously.
For reducing the value:
u
Let the display move to the maximum setting value. Then the cycle starts again at the minimum
setting value.
3: Acknowledge parameter value
SP1
u
Briefly press [Mode/Enter].
w
The parameter is displayed again. The new setting value is saved.
Setting other parameters:
u
Start again with step 1.
Finishing the parameter setting:
u
Press [Mode/Enter] several times until the current measured value is displayed, or wait for 30 s.
w
The sensor returns to the process value display.
If [C.Loc] is displayed when an attempt is made to modify a parameter value, a parameter
setting process is active via the IO-Link communication (temporary locking).
If [S.Loc] is displayed, the sensor is permanently locked via software. This locking can only be
removed with a parameter setting software.
Changing from menu level 1 to menu level 2
EF
u
Press [Mode/Enter] until [EF] is displayed.
rES
u
Briefly press [Set].
w
The first parameter of the submenu is displayed (here: [rES]).
Locking / unlocking
The device can be locked electronically to prevent unintentional settings.
Locking: