CR1204
10
4.3.2 Installation with installation kit
The installation kit enables horizontal, vertical or overhead mounting of the device in a panel cut-out.
This type of mounting is suited for materials with a thickness from 1 to 10 mm.
The fixing blocks, M5 set screws, washers, and M5 hexagon nuts required for mounting are supplied
with the installation kit.
Fig. 2: Dialogue module with mounted installation kit
4.3.3 Panel cutout
u
Make a cut-out.
21
1,5
337,5
4 x R7
Fig. 3: Panel cut-out
Tolerances: ± 0.5 mm
4.3.4 Mounting steps
u
Screw the set screws into the M5 thread on the back of the device: Location for mounting
accessories (
7).
u
Insert the device into the cut-out.
u
Screw the fixing blocks to the back of the device.
Tightening torque of the M5 hexagon nuts: 5
±0,5
Nm